Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung Toshiba, modell TD-Z551

Hersteller: Toshiba
Dateigröße: 42.04 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


By holding down both the ^ andЎ button on the monitor for 3 seconds or longer again, you can unlock the operation buttons. OSD information HDMI1, HDMI2, DVI-D, D-SUB, DISPLAYPORT Current selection (DVI-D) Resolution Horizontal/vertical frequency Audio input mode Picture size mode OPTION (OPS-compliant computer) Current selection ((OPTION (OPS-compliant computer))Resolution Horizontal/vertical frequency Audio input mode Picture size mode YPbPr Current selection (YPbPr) Audio input mode Picture size mode S-VIDEO, VIDEO Current selection (S-VIDEO) Color system mode Audio input mode Picture size mode PIP, POP Main : DVI-D Sub : S-VIDEO Main picture information Audio input mode Sub picture information Main picture size Control Lock mode 65 Other functions Supplemental information of the auto brightness function Audio input change You can select the audio input using the AUDIO INPUT button.Note that the selectable audio inputs vary depending on the currently selected video signal input. Selection of the video signal input Operation HDMI1 or HDMI2 DVI-D ANALOG only D-SUB ANALOG only OPTION** PC (OPS-compliant computer) DISPLAYPORT YPbPr ANALOG only S-VIDEO ANALOG only VIDEO ANALOG only * The audio of HDMI1 or HDMI2 being selected is output as the HDMI audio. ** OPTION can be used when an expansion module is mounted on the option slot. Supplemental information of the auto brightness function To control multiple monitors collectively In such a case where the tiling function is used, you can control the auto brightness function by sharing the detection result of the brightness sensor of a certain monitor among the connected monitors. 1 Multi-connect the monitors using RS-232C cables (commercially available) as shown by the example below. Master: Monitor conf gured as Master that detects the outside light (Monitor ID is “1”.) Slave: Monitor controlled by the Master monitor (Monitor ID is other than “1”.) 2 Assign a monitor ID to each multi-connected TD-Z551/ TD-Z701 using MONITOR ID. (See page 58.) Monitor ID is selectable from 1 to 26. The monitor ID of the Master monitor should be “1” and those of the Slave monitors should be other than “1”. You are recommended to assign IDs to the monitors consecutively from 1, 2, 3, and on. 3 Set AUTO BRIGHTNESS on the OSD screen (PICTURE) as follows. AUTO BRIGHTNESS CONTROL Master monitor LOCAL PRIMARY Slave monitors REMOTE SECONDARY To use a computer to control the monitors When using a computer to control the monitors, you must prepare an application software program for control by yourself. Brightness of all the monitors can be controlled centrally using a computer, if the customer create a control application to remotely read the value from two brightness sensors of any monitor and distribute it to all monitors. 1 Connect the RS-232C IN connector of the Master monitor shown above and the RS-232C connector of the computer using an RS-232C cable. The communication control function via LAN isn’t supported on the monitor alone, however, it is available when the monitor is used with the computer. Audio input change 2 Assign a monitor ID to each multi-connected TD-Z551/TD-Z701 using MONITOR ID. (See page 58.) Monitor ID is selectable from 1 to 26. 3 Set AUTO BRIGHTNESS on the OSD screen (PICTURE) as follows. AUTO BRIGHTNESS CONTROL Master monitor REMOTE SECONDARY Slave monitors REMOTE SECONDARY 4 A control application made by the customer reads the value from two brightness sensors of any monitor and distributes it to all monitors. For the specif cations of the communication commands, contact your dealer. PIP, POP function The following table shows the combinations of signal inputs with which the “PIP” and “POP” modes function. However, these modes do not function when the screen size is “CUSTOM” or “REAL”. Sub screen HDMI1 HDMI2 DVI-D D-SUB OPTION* DISPLAY PORT YPbPr S-VIDEO VIDEO Main screen HDMI1 x x x x x x x 0 0 HDMI2 x x x x x x x 0 0 DVI-D x x x x x x x 0 0 D-SUB x x x x x x x 0 0 OPTION* x x x x x x x 0 0 DIS PLAY PORT x x x x x x x 0 0 YPbPr x x x x x x x 0 0 S-VIDEO 0 0 0 0 0 0 0 x x VIDEO 0 0 0 0 0 0 0 x x 0: Supported . : Not supported * OPTION can be used when an expansion module is mounted on the option slot. By pressing the PIP ON/OFF button on the wireless remote control, you can change the PIP, POP, and SBS modes in the order shown below.Alternatively, you can change the modes using the PIP MODE setting of PIP in the OSD main menu. See page 55. The resolutions in the PIP and SBS FULL modes are as follows: PIP SIZE < SMALL > : 450 pixels X 338 pixels < MIDDLE > : 675 pixels X 450 pixels < LARGE > : 900 pixels X 675 pixels SBS FULL : 960 pixels X 1080 pixels When the PIP or SBS FULL mode has been selected, images in the sub picture always fit the size of each mode shown above irrespective of the aspect ratio of the input image. PIP, POP function Remote control numbering function By connecting multiple TD-Z551 and TD-Z701 monitors using RS-232C cables, you can control...

Dieses Handbuch ist für folgende Modelle:
Fernseher - TD-Z551E (42.04 mb)
Fernseher - TD-Z551U (42.04 mb)
Fernseher - TD-Z701 (42.04 mb)
Fernseher - TD-Z701E (42.04 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien