Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Tecumseh, modell SNOW KING OH195SP

Hersteller: Tecumseh
Dateigröße: 1.84 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


NOTE If engine is remotely controlled, (see equipment manufacturer’s instructions) your equipment may have one or more of the following engine symbols. See Figure 18. This section contains starting instructions for several different types of engines. In order to locate the instructions that apply to your engine, first determine what type of starter you have. If you have an electric starter see "A. Engines with Electric Starters" instructions on page 2. If you have a manual recoil starter see "B. Engines with Recoil Starters" instructions on page 2. STOP STOP SLOW RUN FAST CHOKE PRIMER Figure 18. Typical Engine Symbols 181-1275-14 4-Cycle • Snow King Engine Page 9 A. Engines with Electric Starters If you have a recoil starter see "B. Engines with Recoil Starters" instructions on page 13. !WARNING Some electric starters are equipped with a 120V A.C. Three-Wire Power Cord and Plug designed to operate on a 120V A.C. household current. It must be properly grounded at all times to avoid the possibility of injury or death from electrical shock. a. Determine if your house wiring has a Ground Fault Interrupted (G.F.I.) Three-Wire Grounded System; if you are not sure ask a Licensed Electrician. b. If your house wiring does not have a G.F.I. Three- Wire Grounded System, DO NOT USE THIS ELECTRIC STARTER UNDER ANY CONDITION. c. If your house wiring is grounded and a G.F.I. Three- Prong Wall Receptacle is not available at the location where your starter will be used, one must be installed by a Licensed Electrician BEFORE USING THE ELECTRIC STARTER. 1. To avoid carbon monoxide poisoning, be sure engine is outdoors in a well-ventilated area. 2. Be sure fuel valve, if present (see equipment manufacturer’s instructions) is open and all switches are on. See Figure 19. NOTES If your engine is equipped with a 12V battery-operated electric starter, proceed to step 4. When connecting power cord, always connect power cord to switch box on engine first; then into outlet. See Figure 20. European 220V A.C. Applications use an appropriate grounded extension lead, available locally. 3. Connect power cord to switch box on engine. See Figure 20. 4. Plug end of power cord into outlet. Fuel Valve “OPEN” Position Shown Fuel Tank Turn Valve Clockwise To “OFF” Position Figure 19. Fuel Valve Positions Figure 20. Electric Starter Connections 1. Power Cord to Outlet 2. Switch Box 3. Starter Button 4. Schuko Plug 5. Power Cord to Switch Box on Engine 6. Electric Starter Switch Box on Engine 1 5 2 3 120V A.C. 1 5 2 3 4 220V A.C. 6 Page 10 4-Cycle • Snow King Engine 181-1275-14 5. Move engine speed control to “FAST” position. See Figures 21 and 22. 6. Set choke control to “FULL CHOKE” position (see equipment manufacturer’s instructions). See Figure 24 on page 12. Afterward, continue reading instructions below. 7. Hold the primer bulb in for one full second each time you press it. See Figure 23. • Make sure you cover vent hole with your thumb. • Repeat twice for a total of three primes. NOTES DO NOT operate an electric starter for more than 5 seconds each attempt. DO NOT use primer bulb to restart a warm engine after a short shutdown. Doing so will flood the engine and may result in equipment malfunction. If restarting a warm engine after a short shutdown, move engine speed control to “FAST” position and move choke control to “NO CHOKE” position. See Figures 21, 22 and 24. Afterward, continue reading instructions below. 8. Push starter button or turn ignition switch key, (see equipment manufacturer’s instructions), to start engine. See "C. Check the Following Items" instructions on page 6. Afterward, continue reading instructions below. NOTE If engine fails to start after 3 attempts repeat steps 1 thru 8. 9. When engine starts: a. Release starter button or ignition switch key. b. Momentarily move choke control to “1/2 CHOKE” position until engine runs smoothly. See Figure 24 on page 12. Afterward, continue reading instructions below. c. Next, move choke control to “NO CHOKE” position. 10. Move engine speed control to desired speed in “RUN” range. See Figures 21 and 22. NOTES If engine starts but falters when choke control is moved to “NO CHOKE” position: a. Momentarily move choke control back to “FULL CHOKE” position. b. Next, move choke control to “1/2 CHOKE” position until engine runs smoothly. c. Finally, move choke control to “NO CHOKE” position. If engine dies after choke control is moved to “NO CHOKE” position repeat steps 5 thru 10 to restart engine. 11. If engine fires but does not continue to ...

Dieses Handbuch ist für folgende Modelle:
Schneefräsen - SNOW KING LH195SA (1.84 mb)
Schneefräsen - SNOW KING LH195SA (1.84 mb)
Schneefräsen - SNOW KING LH195SP (1.84 mb)
Schneefräsen - SNOW KING LH318SA (1.84 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien