heruntergeladen wurde: 3   Dateigröße: 464 kb   Hersteller: York  
Kategorie: Lüftungs
@name

These bases have a durable finish to match the evaporator blower unit. They may have to be insulated for certain applications. SUSPENSION PACKAGES: These accessories can be used to suspend horizontal units from above without interfering with access to the unit. They can also be used for elevating a floor-mounted unit (either horizontal or vertical) to provide additional height for the installation of a trap at the condensate drain connection. All suspension packages can be used with vibration is

heruntergeladen wurde: 2   Dateigröße: 464 kb   Hersteller: York  
Kategorie: Lüftungs
@name

Do not use steam in hot water coils. Do not operate the supply air blower above its nominal HP rating when a unit is equipped with a steam coil accessory. Although these coils are suitable for a much higher pressure, steam above 25 psig provides too much heat that could damage the blower motor. 1. These units are equipped from the factory with a correctly sized motor starter; overload elements are not factory supplied. Note: Three elements required per unit. Unitary Products Group 036-21335-002-

heruntergeladen wurde: 15   Dateigröße: 464 kb   Hersteller: York  
Kategorie: Lüftungs
@name

LA300, LB360 & 480 canbepositioned inupto12 different positionsand suspended in various positions. The LB600 can be positioned in up to 7 different arrangements and suspended also. The LA/ LB line will give you the power to condition large amounts of building space and the ability to conform to almost any situation. FEATURING • EASE OF SERVICE • PUMP-OUT ON START-UP • BASE SECTIONS (25, 30 & 40 Ton only) • SUSPENSION PACKAGES • HOT WATER COILS • STEAM COILS (LA300 & LB360 only) • WIDE RANGE OF B

heruntergeladen wurde: 6   Dateigröße: 464 kb   Hersteller: York  
Kategorie: Lüftungs
@name

Unit resistance is based on a dry evaporator coil and clean filters. 2. Available static pressure in IWG to overcome the resistance of the duct system and any accessories added to the unit. Refer to the blower motor and drive table and the accessory static resistance table for additional information. 3. Motors can be selected to operate into the service factor because they are located in the moving air stream, upstream of any heating device. units with steam or hot water coils are the only excep

heruntergeladen wurde: 9   Dateigröße: 204 kb   Hersteller: York  
Kategorie: Lüftungs
@name

- Water temperature 7/12 °C (2) Room temperature 20°C, 50% R.H. - Water inlet temperature: 50°C - Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397 (3) Sound pressure level in 1 meter distance open field and 0 Pa external static pressure ill YORK Blower 4 to 24 kW ifSl Compatibility table / Codes Models YEFB 130-140 YEFB 230-240 YEFB 330-340 YEFB 430-440 Options (factory fitted) Auxiliary hot water coil (2 or 3 rows) • • • • Paint finish • • • •

heruntergeladen wurde: 55   Dateigröße: 204 kb   Hersteller: York  
Kategorie: Lüftungs
@name

fan speed and automatic change over CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve Technical features Model YEFB 130 140 230 240 330 340 430 440 Total cooling capacity [kW] (1) max 6.01 6.92 8.81 10.61 11.15 14.06 17.86 23.31 med 5.13 5.81 7.27 8.55 9.39 11.58 16.28 20.95 mln 3.22 3.49 6.08 7.01 7.51 9.00 14.40 18.21 Heating capacity [kW] (2) max 7.90 8.90 12.34 14.62 15.20 18.84 24.38 30.36 med 6.61 7.32 9.84 11.36 12.49 15.07 21.

heruntergeladen wurde: 3   Dateigröße: 204 kb   Hersteller: York  
Kategorie: Lüftungs
@name

heater) • • • • CER20 2 and 4 pipe, on/off valves (or El. heater) • • • • CER30 2 and 4 pipe, modulating valves • • • • Discharge plenum KPM 100-200 KPM 300 KPM 400 Condensate pump KPC 100-400 • Available Dimensions and minimum spaces Mod. A B C D E F G H 100-200 989.6 800 331 948.6 290 21.5 362 158 300 1239.6 900 350 1198.6 309 21.5 462 158 400 1633 900 439.3 1592 398.3 21.5 450 158 Mod. A B C 100-200 331 954 306 300 350 1 204 300 400 440 1 597 311 E-COM-H0707 Ü1YORK

heruntergeladen wurde: 10   Dateigröße: 204 kb   Hersteller: York  
Kategorie: Lüftungs
@name

available external static pressure [Pa] 100 100 175 175 250 250 250 250 Sound pressure level [dB(A)](3) max 56 56 60 60 60 60 67 67 med 51 51 54 54 54 54 64 64 mln 41 41 49 49 48 48 59 59 Power supply [V-ph-Hz] 230 - 1- 50 Water connections G 1/2” F G 1/2” F G 1/2” F G 1/2” F G 1/2” F G 1/2” F G 1” M G 1” M (1) Room temperature 27°C d.b., 48% R.H. - Water temperature 7/12 °C (2) Room temperature 20°C, 50% R.H. - Water inlet temperature: 50°C - Water flow values as Cool

heruntergeladen wurde: 2   Dateigröße: 164 kb   Hersteller: York  
Kategorie: Lüftungs
@name

A (0501) MODEL K3EU180A50 (WORLD 50 HZ) GENERAL This completely assembled blower unit is manufactured under ISO 9002 Quality System Certification and includes a well- insulated cabinet, a DX cooling coil with copper tubes and aluminum fins, an expansion valve, a distributor, throwaway filters, a centrifugal blower, a blower motor, a blower motor contactor, an adjustable belt drive and a small holding charge of Refrigerant-22. The unit is shipped in the vertical position with a vertical air disch