Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung Yamaha, modell CS6x

Hersteller: Yamaha
Dateigröße: 7.39 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


. Settings: 1 ~ 16, omni (all channels), off ¦ Trans (Keyboard Transmit Channel) Set the MIDI Transmit channel for transmitting MIDI from the keyboard, controllers and so on. . Settings: Ch1 ~ Ch16, off ¦ Local (Local On/Off) If you set Local to “off,” the keyboard and controllers are internally disconnected from the synthesizer’s tone generator section so that no sound is output when you play the keyboard or use the controllers. However, the data will be transmitted through the MIDI OUT. Also, the tone generator section will respond to messages received at the MIDI IN. . Settings: off on, ¦ DevNo (Device Number) Set the MIDI Device Number. This number must match the Device Number of the external MIDI device when transmitting/receiving bulk data, parameter changes or other system exclusive messages to/from it. . Settings: 1 ~ 16, all, off MIDI Arp (MIDI Arpeggio) Set the arpeggiator’s MIDI parameters. MIDI Arp) Switch Hold Out(Vce)Ch(Vce) Sys[ ] 67 68 off 16 ¦ Switch Select the Control Change Number used to control the ARPEGGIO [ON/OFF] key. . Settings: 000 ~ 095 (000, 032 = off) ¦ Hold Select the Control Change Number used to control the ARPEGGIO [HOLD] key. . Settings: 000 ~ 095 (000/032 = off) ¦ Out (Vce) Enable/disable the output or Arpeggiator data to external MIDI devices through the MIDI Out. . Settings: off (disabled), on (enabled) ¦ Ch (Vce) (Arpeggio Transmit Channel) Select the MIDI channel through which Arpeggio data will be sent. . Settings: 1 ~ 16 MIDI Sw (MIDI Receive Switch) Set the MIDI Receive parameters. MIDI Sw)RcvBulk BankSel PgmChng Control Sys on perform off mode1 ¦ RcvBulk (Receive Bulk) Select whether or not Bulk Dump data can be received. . Settings: protect (off), on ¦ BankSel (Bank Select) Set to enable or disable transmission and reception of Bank Select messages between the instrument and an external MIDI device. With any setting other than “off,” the instrument can receive a Bank Select massage coming in, and it can also send a Bank Select massage out to an external MIDI device when you select a Bank using a MEMORY key or the like on its front panel. . Settings: off, all, part, perform off: Ignores (does not receive) a Bank Select message. The instrument does not send this message, either. all: Receives all Bank Select messages coming in. When the instrument receives only a Program Change message in Performance Mode, that message selects a Part’s Voice. part: Receives only Bank Select messages for selecting a Voice Bank, whichever mode you are working in. perform: Receives only Bank Select messages for selecting a Performance Bank when you are working in Performance Mode. When you are working in Voice Mode, the instrument only receives Bank Select messages for selecting a Voice Bank. 166 ¦ n . Settings: off (disable), on (enable) ¦ Control Set the MIDI transmit/receive parameters for the CS6x’s 14 Sound Control knobs. . Settings: mode1, mode2 mode1: If the knob’s Control Change message is not a standard MIDI message, it is transmitted as a Parameter Change message instead. mode2: The [SUSTAIN] knob transmits a Control Change message. MIDI Other Set other MIDI parameters. MIDI Other) In ThruPort Sync SeqCtrl Sys MIDI 1 int on ¦ In (MIDI Input) Select whether to use the MIDI In/Out/Thru connectors or other (future) connectors. At present, you can only select “MIDI.” . Settings: MIDI ¦ ThruPort You can connect your synthesizer to a computer via a dedicated serial cable on the TO HOST connector. In which case, MIDI messages received via the TO HOST connector can be passed through the MIDI OUT connector of the synthesizer. Set the port number here. . Settings: 1 ~ 8 ¦ Sync To synchronize playback with an external MIDI device, you can use either the synthesizer’s internal clock (int) or MIDI clock signals from the external device (midi). Select “int” if you are using the synthesizer as the master, or if you have no other MIDI devices connected to it. Select “MIDI” when slaving your synthesizer to another MIDI Clock source connected to the MIDI IN connector. . Settings: MIDI, int (internal) ¦ SeqCtrl (Sequencer Control) Select whether or not to transmit/receive Song Start, Stop and Continue messages via MIDI. This also switches the transmission of MIDI Clock messages on and off. . Settings: off, on MIDI GM/XG Receive (if a Multi-PartPlug-in Board has been installed) Set GM On and XG Reset Receive parameters. This screen is only available if a Multi-Part XG Plug-in Board has been installed. MIDI GM/XG Receive) Sw InternalPart Sys on layer-part ¦ Sw (Receive Switch) Select whether or not to receive GM On and XG Reset messages. The XG Plug-in Board will receive GM On and XG Reset messages if you set this to “on.” o Settings: off, on ¦ InternalPart The sound for each of the synthesizer’s Parts can be output in the following three ways. when a GM On/XG Reset message is received. Whichever setting you choose, the Parts of the XG Plug-in Board will always be output. . Settings: all part: Al...

Dieses Handbuch ist für folgende Modelle:
Musikinstrumente - CS6-R (7.39 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien