Hersteller: Yamaha
Dateigröße: 1.29 mb
Dateiname:
|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
This situation is “Local Control On,” since the internal tone generator is controlled locally by its own keyboard. Local control can be turned OFF, however, so that the the keyboard of the instrument does not play the internal voices, but the appropriate MIDI information is still transmitted via the MIDI OUT terminal when notes are played on the keyboard. At the same time, the internal tone generator responds to MIDI information received via the MIDI IN terminal. While holding down the [DEMO] button, press and hold the [METRONOME ON/OFF] button, NOTE Default setting: ON then press one of the A#5 key. Pressing the A#5 key repeatedly toggles between Local Control On and Off. A#5 NP-11 NP-31 NP-31/NP-11 MIDI Reference 2 MIDI Functions MIDI Functions F Normally the instrument will respond to MIDI program change numbers received from an external keyboard or other MIDI device, causing the same numbered voice to be selected on the corresponding channel (the keyboard voice does not change). The instrument will normally also send a MIDI program change number whenever one of its voices is selected, causing the same numbered voice or program to be selected on the external MIDI device if the device is set up to receive and respond to MIDI program change numbers. This function makes it possible to cancel program change number reception and transmission so that voices can be selected on the instrument without affecting the external MIDI device. While holding down the [DEMO] button, press and hold the [METRONOME ON/OFF] button, then press one of the B5 key. Pressing the B5 key repeatedly toggles between Program Change On and Off. B5 NP-11 NP-31 Control Change ON/OFF NOTE For information on program change numbers for each of the Voices of the instrument, refer to page 4. NOTE Default setting: ON Normally the instrument will respond to MIDI control change data received from an external MIDI device or keyboard, causing the voice on the corresponding channel to be affected by pedal and other “control” settings received from the controlling device (the keyboard voice is not affected). The instrument also transmits MIDI control change information when the pedal or other appropriate controls are operated. This function makes it possible to cancel control change data reception and transmission so that, for example, the pedal of the instrument and other controls can be operated without affecting an external MIDI device. While holding down the [DEMO] button, press and hold the [METRONOME ON/OFF] button, then press one of the C6 key. Pressing the C6 key repeatedly toggles between Control Change On and Off. C6 NP-11 NP-31 NOTE For information on control changes that can be used with the instrument, refer to page 4. NOTE Default setting: ON NP-31/NP-11 MIDI Reference 3 MIDI Data Format MIDI Data Format 1. NOTE ON/OFF Data format: [9nH] -> [kk] -> [vv] 9nH = Note ON/OFF event (n = channel number) kk = Note number (Transmit: 09H–78H = A-2–C8 / Receive: 00H–7FH = C-2–G8) vv = Velocity (Key ON = 01H–7FH, Key OFF = 00H) Data format: [8nH] -> [kk] -> [vv] (reception only) 8nH = Note OFF event (n = channel number) kk = Note number: 00H–7FH = C-2–G8) vv = Velocity 2. CONTROL CHANGE Data format: [BnH] -> [cc] -> [vv] BnH = Control change (n = channel number) cc = Control number vv = Data Range (1) Bank Select ccH Parameter Data Range (vvH) 00H Bank Select MSB 00H:Normal 20H Bank Select LSB 00H...7FH Bank selection processing does not occur until receipt of next Pro gram Change message. (2) Main Volume ccH Parameter 07H Volume (3) Expression (reception only) ccH Parameter 0BH Expression (4) Sustain ccH Parameter 40H Sustain (5) Sostenuto (reception only) ccH Parameter 42H Sostenuto (6) Soft Pedal (reception only) ccH Parameter 43H Soft Pedal Data Range (vvH) 00H...7FH Data Range (vvH) 00H...7FH Data Range (vvH) 00H...7FH Data Range (vvH) 00H...3FH:off, 40H...7FH:on Data Range (vvH) 00H...3FH:off, 40H...7FH:on (7) Effect1 Depth (Reverb Send Level) ccH Parameter Data Range (vvH) 5BH Effect1 Depth 00H...7FH Adjusts the reverb send level. (8) Effect4 Depth (Variation Effect Send Level) ccH Parameter Data Range (vvH) 5EH Effect4 Depth 00H...7FH (9) RPN 65H RPN MSB 64H RPN LSB 06H Data Entry MSB 26H Data Entry LSB 60H Data Increment 61H Data Decrement * Parameters that are controllable with RPN: • Coarse Tune • Fine Tune • Pitch Bend Range 3. MODE MESSAGES Data format: [BnH] -> [cc] -> [vv] BnH = Control event (n = channel number) cc = Mode Message number vv = Data Range (1) All Sound Off ccH Parameter Data Range (vvH) 78H All Sound Off 00H (2) Reset All Controllers ccH Parameter Data Range (vvH) 79H Reset All Controllers 00H Resets controllers as follows. Controller Value Expression 127 (max) Sustain Pedal 0 (off) Sostenuto 0 (off) Soft Pedal 0 (off) (3) Local Control (reception only) ccH Parameter Data Range (vvH) 7AH Local Control 00H (off), 7FH (on) (4) All Notes Off ccH Parameter Data Range (vvH) 7BH All Notes Off 00H Switches OFF all the notes ...