Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung ADC, modell 5e

Hersteller: ADC
Dateigröße: 92.48 kb
Dateiname: e7c8302e-cea4-4ca4-aaa5-14a6f7ab2530.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


c o m • + 1 -9 5 2 -9 3 8 -8 0 8 0 • 1 -8 0 0 -3 6 6 -3 8 9 1 Basic Structured Cabling Systems Category 5e 4-Pair Riser Data Cable ADC’s Basic Category 5e and Category 6 Structured Cabling Systems are complete channel solutions offering 20-year product performance warranties along with a multitude of product choices and design options. In addition, the components of these economical systems are also guaranteed to meet the minimum requirements of TIA 568B for Category 5e and Category 6 for dependable data transmission in any network configuration, from the switch to the network interface. Features: • Unparalleled delay skew performance • Manufactured with lead-free materials Compliances: • UL Subject 444 • (UL)-C(UL) Type CMR/CMG • (UL)-C(UL) Type CM/CMH • ICEA S-90-661 • NEC 800 Type CMR or CM • ISO/IEC 11801 Class D • ETL verified TIA/EIA-568-B.2 Category 5e horizontal cable requirements Basic Structured Cabling Systems Category 5e 4-Pair Riser Data Cable ADC’s Basic Category 5e and Category 6 Structured Cabling Systems are complete channel solutions offering 20-year product performance warranties along with a multitude of product choices and design options. In addition, the components of these economical systems are also guaranteed to meet the minimum requirements of TIA 568B for Category 5e and Category 6 for dependable data transmission in any network configuration, from the switch to the network interface. Features: • Unparalleled delay skew performance • Manufactured with lead-free materials Compliances: • UL Subject 444 • (UL)-C(UL) Type CMR/CMG • (UL)-C(UL) Type CM/CMH • ICEA S-90-661 • NEC 800 Type CMR or CM • ISO/IEC 11801 Class D • ETL verified TIA/EIA-568-B.2 Category 5e horizontal cable requirements Spec Sheet Basic Structured Cabling Systems Category 5e 4-Pair Riser Data Cable 10/ 06 • 101848AE Category5e4- PairRiserDataCable Specifications CONSTRUCTION Conductors: 24 AWG solid bare copper Insulation: Polyolefin Pairing: Short, staggered pair lays Jacket: Lead-free, flame retardant PVC Nominal outer diameter: 4.7 mm (.185") ELECTRICAL CHARACTERISTICS Conductor DC resistance (maximum): 9.38 ./100 meters (28.6 ./1000 ft) @ 20 °C (68 °F) DC resistance unbalance (maximum): 2% Mutual capacitance (maximum): 5.6 nF/100 meters (17 pF/ft) Operating temperature (maximum): 75 °C (167 °F) Operating voltage (maximum): 300 VDC Worst case cable skew: 25 nS/100 meters (25 nS/328 ft) Nominal velocity of propagation: 69% Freq (MHz) Fitted Impedance (Ohms) Insertion Loss (dB/100m) Return Loss (dB/100m) Pair-Pair NExT (dB/100m) PSNExT (dB/100m) Spec Max Spec Min Spec Min Spec Min Spec 1 100 +/-15 1.9 2.0 30.1 20.0 73.4 65.3 70.9 62.3 4 100 +/-15 3.9 4.1 27.5 23.0 66.7 56.3 65.0 53.3 8 100 +/-15 5.5 5.8 31.3 24.5 61.5 51.8 59.7 48.8 10 100 +/-15 6.2 6.5 28.6 25.0 60.1 50.3 57.6 47.3 16 100 +/-15 7.8 8.2 31.2 25.0 53.8 47.2 52.9 44.2 20 100 +/-15 8.8 9.3 30.8 25.0 57.5 45.8 54.5 42.8 25 100 +/-15 9.9 10.4 30.5 24.3 52.3 44.3 53.0 41.3 31.25 100 +/-15 11....

Dieses Handbuch ist für folgende Modelle:
Netzwerk - 6 (92.48 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien