|
Anleitung Zusammenfassung
This will continue for 8 minutes and then stop. Proceed to Faucet Operation, page 6. Bradley Corporation •215-1559 Rev. A; EN 04-216A 9/23/04 Aerada 1000 Series Gooseneck Faucet Installation Instructions Faucet Operation Operating Modes • Normal Motion Detecting Mode: water flows within 1/4 second after activating sensor (i.e., putting hands in front of collar) and continues to stay on as long as motion is detected. Maximum time is 45 seconds (factory default setting). • Scrub Mode: water continues to flow for 60 seconds (default) after deactivating the sensor (removing hands). • Metered Mode: water flows for 10 seconds (default) from first hand detection. • Water Saver Mode: water flows for a maximum of 5 seconds starting from first hand detection and immediately turns off when hands are removed. Additional Operating Features • 12-second, no-motion turn off in normal mode • “Low battery” indication • Battery life up to one year depending on frequency of use. Changing Faucet Operation In order to change any faucet option, the DIPswitch must be used (located inside the electronics cover assembly, see illustration this page). Checking/Changing DIPswitch Settings 1. Remove the electronics cover (1) from the baseplate (2). 2. Lift the partition (3) out to expose the circuit board and DIPswitch. 3. To change a DIPswitch setting, use a small pointed object to move the appropriate DIPswitch to ON or OFF. Faucet range and mode settings along with their corresponding DIPswitch settings are outlined in Table 1 and Table 2 Resetting Faucet Electronics In order to reset the faucet electronics, a reset button located inside the electronics cover assembly must be pushed in (see illustration this page). To reset faucet electronics: Electronics Cover Assembly & DIPswitch ON ON OFF OFF 1 2 3 4 5 1 2 3 4 5 MANUALRESETBUTTONDIPSWITCHES3 1 2 1. Remove hex screw holding the electronics cover to the baseplate and remove cover. 2. Lift the partition out to expose the circuit board and reset button. 3. Make sure there are no objects in front of the collar sensor, then push the button to reset. 4. Wait 30 seconds for faucet to automatically calibrate to the environment. 5. Activate water flow by placing your hand in front of the sensor. 6. Place partition into the electronics cover. 7. Place the electronics cover onto the baseplate and secure with the hex screw. NOTE: Resetting the faucet electronics causes loss of virtual settings and time in use, and will also start the 8-minute timer where the LED on the electronics box will blink and an audible indicator chirps twice per second whenever hand presence is detected. Range Short Normal Far Maximum Switch 1 off on on off Switch 2 off off on on Table 1 - Faucet Range Normal Scrub Meter Water Saver Modes Mode Mode Mode Mode Switch 3 off on off off Switch 4 off off on off Switch 5 off off off on Table 2 - Faucet Mode 9/23/04 Bradley Corporation •215-1559 Rev. A; EN 04-216A Installation Instructions Aerada 1000 Series Gooseneck Faucet Troubleshooting Whenever new batteries are installed, AC power is applied, or a manual reset button is pressed, the LED on the electronics cover will blink and an audible indicator chirps twice per second whenever hand presence is detected. After 8 minutes, the LED and buzzer function stops. If an error occurs, the LED will blink and the buzzer will sound every 30 seconds to assist in diagnosing the problem. When corrective action is taken the LED and buzzer will stop. The following chart provides...
Dieses Handbuch ist für folgende Modelle:Plumbing - AERADA 1000 Series 232-007 (227.87 kb)
Plumbing - AERADA 1000 Series S53-307 (227.87 kb)
Plumbing - AERADA 1000 Series S53-308 (227.87 kb)
Plumbing - AERADA 1000 Series S53-306 (227.87 kb)