Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 41717-01 05/31/2006 2 41717-EngS_05.31.06.indd 2 5/31/06 3:53:11 PM 3 D 95047-01-000 E 03242-07-133 F G 95374-01-000 I 94998-01/02-000 75192-01-000 3/8" Cable Connector Extra Screws * A * B * NOTE: Strain relief cable connector must be installed. Not Included. x2 H x3 C 74508-03-133 x2 H Included. Turn off the power source. D 95047-01-000 E 03242-07-133 F G 95374-01-000 I 94998-01/02-000 75192-01-000 3/8" Cable Connector Extra Screws * A * B * NOTE: Strain relief cable connector must be installed. Not Included. x2 H x3 C 74508-03-133 x2 H Tools Needed. Estimated assembly time: 30 to 60 minutes Before Installation Check all the parts. If damaged, call 1-888-830-1326 for replacements. New construction installation Go to Step A1, page 4 Existing construction Go to Existing Construction Installation, page 8 41717-01 05/31/2006 NOTE: Remove all packing materials before installation 41717-EngS_05.31.06.indd 3 5/31/06 3:53:13 PM A1 D Back out the pre-loaded screw tips until flush with the side of the housing. Remove the motor/blower from the housing. Remove the wiring cover screw. 4 Remove packing material. A2 A3 A6 E Remove tape. A4 A5 Remove the pre-loaded screw tip covers. New Construction Installation 41717-01 05/31/2006 41717-EngS_05.31.06.indd 4 5/31/06 3:53:15 PM A7 F A8 D A9 B C A10 D 5/8 1/2 5/8 1/2 A11 OPTION Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Position the correct depth mark at the bottom edge of the joist–based on the thickness of your sheet rock. Screw pre-loaded screws into joist or framing. Nail the tabs on both sides to joist or framing so that the housing will be flush with the finished ceiling. Nails are not provided. 41717-01 05/31/2006 5 41717-EngS_05.31.06.indd 5 5/31/06 3:53:18 PM A017 D A12 A13 A A A Green Black White Bare Copper A14 Ground B D A16 F Pull the wires through the strain relief. Tighten the strain relief screws. Connect wires as shown. Connect a 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 6 F A15 B D 41717-01 05/31/2006 41717-EngS_05.31.06.indd 6 5/31/06 3:53:21 PM I A23 0 D A18 G 0 G D A19 A21 ON OFF A22 Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. Turn on the power source. Test the motor. If the motor does not run, check the plug connection. 7 A20 H Insert one spring clip of the fan cover into the slot on the motor housing. 41717-01 05/31/2006 41717-EngS_05.31.06.indd 7 5/31/06 3:53:24 PM B1 D 7.25” 7.75” D Use the motor housing as a template to mark position. Cut out an opening for the housing. Remove the existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7.25” x 7.75”). Existing Construction Installation Existing Fan 8 Remove tape. A24 I Push the cover into place. 41717-01 05/31/2006 41717-EngS_05.31.06.indd 8 5/31/06 3:53:27 PM B2B3 Remove the motor/blower from the housing. Remove packing material. B4Remove the pre-loaded screw tip covers. B5 Back out the pre-loaded screw tips until flush with the side of the housing. B6EB7FRemove the wiring cover screw. Remove the wiring cover. 41717-01 05/31/2006 9 41717-EngS_05.31.06.indd 9 5/31/06 3:53:29 PM B8 D Pull the wires through the strain relief and tighten the strain relief screws. B9 B C D B10 B11 2 1 B12 D B13 10 Fit housing into the opening and secure by tightening the pre-loaded screws into the joist. Note: Install the box flush with the sheetrock (ceiling). Insert the strain relief into the housing and secure with the washer. Move the housing into position above the ceiling. Pop out the first wiring access slug. Use second if needed. 41717-01 05/31/2006 Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. 41717-EngS_05.31.06.indd 10 5/31/06 3:53:32 PM D F E B16 D B14 A A A Green Black White Bare Copper B15 Ground B D D B17 0 G D B18 Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 11 Connect the wirin...
Dieses Handbuch ist für folgende Modelle:Receiver und Verstärker - SPA SELECT 90051 (3.36 mb)
Receiver und Verstärker - SPA SELECT 90059 (3.36 mb)