Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.2 ( )

Anleitung APC, modell AXFA11G

Hersteller: APC
Dateigröße: 1.3 mb
Dateiname: IM01E20C0101E005.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


1-1 1.1 Using the Magnetic Flowmeter Safely ........................................................... 1-2 1.2 Warranty .......................................................................................................... 1-2 1.3 Combination Remote Flowtubes..................................................................... 1-3 2. HANDLING PRECAUTIONS............................................................................... 2-1 2.1 Checking Model and Specifications ............................................................... 2-1 2.2 Accessories ...................................................................................................... 2-1 2.3 Storage Precautions ......................................................................................... 2-1 2.4 Installation Location Precautions .................................................................... 2-1 3. INSTALLATION .................................................................................................... 3-1 3.1 Installation Location........................................................................................ 3-1 3.2 Mounting ......................................................................................................... 3-1 4. WIRING ................................................................................................................... 4-1 4.1 Wiring Precautions .......................................................................................... 4-1 4.2 Cables .............................................................................................................. 4-1 4.3 Wiring Ports .................................................................................................... 4-2 4.4 Wiring Connections ........................................................................................ 4-4 4.4.1 Removing Cover ...................................................................................... 4-4 4.4.2 Terminal Configuration............................................................................ 4-4 4.4.3 Precautions for Wiring of Power Supply Cables ..................................... 4-5 4.4.4 DC Power Connection ............................................................................. 4-5 4.4.5 Grounding ................................................................................................ 4-6 4.4.6 Wiring the Remote Flowtube with the AXFA11 Converter ..................... 4-6 4.4.7 Connecting to External Instruments ........................................................ 4-7 5. BASIC OPERATING PROCEDURES (USING THE DISPLAY UNIT) ........ 5-1 5.1 Operating Panel Configuration and Functions ............................................... 5-1 5.2 Display Unit Setting Methods......................................................................... 5-3 5.2.1 Display Mode > Setting Mode ............................................................... 5-3 5.2.2 Setting Mode ............................................................................................ 5-5 5.3 Parameter Setting Procedure ........................................................................... 5-5 5.3.1 Setting Example for Selection-Type Data: Flow rate units ..................... 5-5 5.3.2 Setting Example for Numeric-Type Data: Flow rate span ....................... 5-7 5.3.3 Setting Example for Alphanumeric-Type Data: Tag number .................. 5-8 5th Edition: Oct. 2006(KP) All Rights Reserved, Copyright © 2003, Yokogawa Electric Corporation i IM 01E20C01-01E CONTENTS 6. PARAMETER DESCRIPTION ............................................................................ 6-1 6.1 Parameters ....................................................................................................... 6-1 6.2 Parameter Lists ................................................................................................ 6-1 6.3 Parameter List Overview ................................................................................ 6-2 6.4 Parameter Description ................................................................................... 6-12 (1) Menu B: Easy Setup items ........................................................................... 6-12 (2) Menu C: Basic Setting items........................................................................ 6-15 (3) Menu D: Total Setting items ........................................................................ 6-17 (4) Menu E: Pulse Setting items ........................................................................ 6-19 (5) Menu F: Status Functions Setting items ...................................................... 6-20 (6) Menu G: Alarm Setting items ...................................................................... 6-25 (7) Menu H: Display Setting items .................................................................... 6-29 (8) Menu J: Auxiliary Function Setting items ..........................


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien