Hersteller: Hitachi
Dateigröße: 141.91 kb
Dateiname: c991bae7-bb8c-4eb9-a0c5-2f03d8801beb.pdf
|
Anleitung Zusammenfassung
Hitachi Chemical Diagnostics retains all rights, title, interest in and copyrights to the materials and information herein. The materials and information contained herein constitute confidential information of Hitachi Chemical Diagnostics and customer shall not disclose or transfer any of these materials or information to any third party. Copyright © 2007 Hitachi Chemical Diagnostics, Inc. 630 Clyde Court Mountain View, California 94043 U.S. and Foreign Patents Pending All rights reserved. No part of this book may be reproduced in any form without written permission from Hitachi Chemical Diagnostics, Inc. Document Number: 0781 Revision: 01 Date: November 2007 1 . Table of Contents . Page 1 Operation Key…………………………………………………………... 3 2 Screen Display and Operation Method 2-1 Initialization……………………………………………………… 4 2-2 Main Menu………………………………………………………. 5 2-3 Panel Type Selection…………………………………………….. 6 2-4 Auto-Run (Process 1 to 7)………………………………………. 7 2-5 Auto-Run (Photoreagent Setup and Process 8)…………………. 9 2-6 Auto-Run (Process End)………………………………………… 10 2-7 Maintenance……………………………………………………... 11 2-8 Pause…………………………………………………………….. 13 2-9 Start/End Process and Position Setup……………………………. 16 2-10 Alarm…………………………………………………………….. 17 3 Flowchart………………………………………………………………... 21 2 1 Operation Key 1 Operation Key Display: Liquid Crystal Panel Operation Key: Only the touch panel key in the shaded field is executable. Press the Operation Key to execute the function. See Figure 1. Numerical Value Input Key: Numerical value can be registered by ‘ENT’ key. If the value entered is out of the defined range, beep sounds will be on for 3 times. ‘ESC’ key is used for returning to the original value. See Figure 2. (Figure 1) (Figure 2) 3 2 Screen Display and Operation Method 2-1 Initialization 2 Screen Display and Operation Method 2-1 Initialization [Screen Display] (Figure 3) (Figure 4) [Summary] Figure 3 will display approximately 5 seconds after the power is turned on. Then the screen will change automatically to the initialization screen, Figure 4. After the completion of initialization, there is a beep sound and Main Menu screen, Figure 5 will display. [Operation Key] (Figure 4) Pause: To Figure 27 Pause screen 4 2 Screen Display and Operation Method 2-2 Main Menu 2 Screen Display and Operation Method 2-2 Main Menu [Screen Display] (Figure 5) (Figure 6) [Summary] Figure 5 is the Main Menu screen after completion of Figure 4. Panel 36 is the default panel. Figure 6 is the Main Menu screen after selecting Panel 20 in Figure 7. [Operation Key] Panel 36: To Figure 7 Panel Type Selection screen Next: To Figure 8 Auto-Run screen Maintenance: To Figure 19 Maintenance screen 5 2 Screen Display and Operation Method 2-3 Panel Type Selection 2 Screen Display and Operation Method 2-3 Panel Type Selection [Screen Display] (Figure 7) [Summary] Select 36-allergen or 20-allergen panel in Figure 7. [Operation Key] 36: To Figure 5 Main Menu screen 20: To Figure 6 Main Menu screen 6 2 Screen Display and Operation Method 2-4 Auto-Run (Process 1 to Process 7) 2 Screen Display and Operation Method 2-4 Auto-Run (Process 1 to Process 7) [Screen Display] (Figure 8) (Figure 9) (Figure 10) (Figure 11) (Figure 12) (Figure 13) (Figure 14) (Continued on next page) 7 (Auto-Run, cont.) [Summary] Figure 8 is a confirmation screen. The Operator needs to check that the Wash Buffer Bottle and Antibody Reservoir are filled, and that the Waste Bottle is emptied prior to the Auto-Run. Press “Start” key. The following screens will be displayed in order and Auto-Run will be executed: o Figure 9 displays the priming is in process. o Figure 10 displays the Rack and Pette setup is being checked. o Figure 11 displays the Rack and Pette setup is confirmed. o Figure 12 displays the washing process (Process 1, 4 or 7) or aspiration process (Process 2 or 5) is in operation. See Chapter 6, Operation, in the AP 720S Instruction Manual. o Figure 13 shows incubation process (Process 3 or 6) is in operation. o Figure 14 is a warning screen during incubation. It indicates the door is open with a beep sound. After the door is closed, the screen will return to Figure 13. In the case the door is open during the operation, i.e. initialization, priming, rack & pettes check, washing, aspirating, rinsing and draining, the screen will switch to Pause (see section 2-8 Pause) [Operation Key] (Figure 8) Start: To Figure 9 Priming screen Back: To Figure 5 Main Menu screen (Figure 9) Pause: To Figure 28 Pause screen (Figure 10) Pause: To: Figure 29 Pause screen (Figure 11) Pause: To: Figure 29 Pause screen (Figure 12) Pause: To: Figure 30 Pause screen 8 2 Screen Display and Operation Method 2-5 Auto-Run (Photoreagent Setup and Process 8) 2 Screen Display and Operation Method 2-5 Auto-Run (Photoreagent Setup and Process 8) [Screen Display] (Figure 15) (Figure 16) (Figure 17) [Summary] Figure 15 will alarm Operator that Photoreagent is needed. The display shows the elapsed time from the start of auto-pause. “...