Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Oregon Scientific, modell RMR613HGA

Hersteller: Oregon Scientific
Dateigröße: 173.8 kb
Dateiname: 355e7a8e-27f8-45f3-8cfe-d5862ab3d7e8.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The signals are collected by the main unit when it is within 1500 km (932 miles) of a signal. Initial reception takes 2 - 10 minutes, and is initiated when you first setup the unit, and whenever you press RESET. Once complete, the reception icon will stop blinking. The icon is shown in the Clock Area. To force a manual search for Atomic Clock signals, press and hold UP for 2 seconds. If no signal is found, check the batteries. NOTE If the Atomic Clock signal is received and the hour is incorrect, use the "hour offset" feature to adjust it to to the right value. Please see "SET CLOCK" on pg. 9 for instructions. 8 RMR613HGA lab test R2 8 1/17/04, 5:00 PM EN TURN ATOMIC CLOCK ON/OFF Perform this step if you cannot receive Atomic Clock signals. Press and hold DOWN for 2 seconds. Then, manually set the clock following the “Set Clock” instructions (below). The signal icon indicates that the Atomic Clock feature is ON. No icon means that it is OFF SET CLOCK You only need to do this if you have disabled the Atomic Clock feature (for example, if you are too far from or cannot receive a signal). 1. Press and hold MODE for 2 seconds. The Clock Area will blink. 2. Select the offset hour, 12 / 24 hour format, hour, minute, year, month, day, and language. Press UP or DOWN to change the setting. Press MODE to confirm. NOTE The language options are (E) English, (F) French, (D) German, (I) Italian, and (S) Spanish. SWITCH CLOCK DISPLAY Press MODE to toggle between Clock with Seconds, Clock with Weekday and Calendar, and Clock with Offset Hour display. ALARMS This product has 2 alarms: a Single Alarm and a Weekday Alarm. The Single Alarm can be set to go off at a specific time for a one-time event (for example, if you are napping on Saturday). The Weekday Alarm will sound at the same time Monday - Friday (but not on weekends). VIEW ALARM SETTINGS Press ALARM to display the Alarm settings you wish to S view: Weekday W or Single . SET ALARM 1. Press ALARM to display the type of Alarm you wish to set: Weekday or Single. 2. Press and hold ALARM for 2 seconds. The Alarm settings will blink. 3. Select the hour and minute. Press UP or DOWN to change settings. Press ALARM to confirm. 9 RMR613HGA lab test R2 9 1/17/04, 5:00 PM EN ACTIVATE ALARM Press ALARM to switch to Weekday or Single Alarm view. To activate or deactivate the alarm, press UP or DOWN. • Alarm deactivated: --:-• Alarm activated: Alarm time is shown The bell icons W and S indicate the alarm display mode selected. SILENCE ALARM When the Alarm time is reached, the crescendo alarm will sound for 2 minutes. Press ALARM to silence it. The Weekday Alarm will sound at the same time the next day provided the next day is Monday - Friday. The Single Alarm will not sound unless you manually activate it again. TEMPERATURE AND HUMIDITY This product can display the following information from the remote sensors: • Current, minimum, and maximum temperatures and relative humidity percentages. • Comfort level Data is collected and displayed every 40 seconds. SELECT TEMPERATURE UNIT Slide the °C / °F switch into the desired location. The switch is located in the battery compartment. The setting for the main unit overrides the remote sensor setting. SELECT SENSOR CHANNEL Press CHANNEL to switch between sensors 1 - 3. The icon shows the selected sensor. 10 RMR613HGA lab test R2 10 1/17/04, 5:00 PM EN Kinetic- wave Icon Designated Display Indoor Display Remote Display Channel 1 Remote Display Channel 2 Remote Display Channel 3 ZONE TEMPERATURE HUMIDITY Any >70% 20 – 25 ° C (68 - 77 ° F) 40 – 70% Any <40% To auto-scan between sensors, press and hold CHANNEL for 2 seconds. Each sensor's data will be displayed for 3 seconds. To end auto-scan, press CHANNEL or MEM. NOTE If you use a sensor that collects only temperature data, humidity will not be shown. MINIMUM / MAXIMUM RECORDS Press MEM to toggle between current, maximum (MAX) and minimum (MIN) records for the selected sensor. To clear the records, press and hold MEM for 2 seconds. A beep will sound to confirm that the memory has been cleared. COMFORT ZONE The Comfort Zone indicates how comfortable the climate is, based on current temperature and humidity measurements. This information is shown in the Humidity Area when the current measurement is displayed. RESET SYSTEM The RESET buttons are located in the battery compartment for the main unit and sensors. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote sensor or radio-controlled clock). NOTE When you press RESET, all settings will return to default value, and you will lose all stored information. 11 RMR613HGA lab test R2 11 1/17/04, 5:00 PM EN SAFETY AND CARE Do not make any changes or modifications to this product. Unauthorized changes may void your right to Clean the product with a slightly damp cloth and alcohol-use the product. The technical specification of this free mild d...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien