Anleitung Black & Decker, modell 90528647
Hersteller: Black & Decker Dateigröße: 3.55 mb Dateiname: c638c8a0-767a-4b3d-b498-fbb1ebcea05a.pdf
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
• Use only as described in this manual. Use only manufacturer’s recommended attachments. • Unplug the charger from outlet before any routine cleaning or maintenance. • This product includes rechargeable nickel cadmium batteries. Do not incinerate batteries as they will explode at high temperatures. • Leaks from battery cells can occur under extreme conditions. If the liquid, which is a 20-35% solution of potassium hydroxide, gets on the skin (1) wash quickly with soap and water or (2) neutralize with a mild acid such as lemon juice or vinegar. If the liquid gets into the eyes, flush them immediately with clean water for a minimum of 10 minutes. Seek medical attention. • Do not look into the air vents when the unit is switched on, as sometimes there is a possibility of small debris being discharged from the air vents, especially after cleaning / replacement of the filters as debris inside the unit can be disturbed. • To prevent tripping accidents, store vacuum after each use. • Do not pick up any sharp objects that may damage vacuum or filters. • Do not operate the unit without both filters in place. Replace a damaged filter promptly. SAVE THESE INSTRUCTIONS PRODUCT FEATURES 1. Release latch for container door 2. Container door 3. Pivot lock release button 4. Beater Bar/Vac On/Off switch 5. Charging indicator 6. Charging base 7. Pivoting arm 8. Beater bar/vac head 9. Pre-filter 10. Inner filter 11. Maintenance access 4 3 8 5 1 2 6 7 10 9 11 90528647 01 PSV1800 PIVOT CRDL VAC 10/16/08 7:47 AM Page 3 4 B C D E F 6 3 A 90528647 01 PSV1800 PIVOT CRDL VAC 10/16/08 7:47 AM Page 4 5 G H I J K L 5 4 2 1 9 90528647 01 PSV1800 PIVOT CRDL VAC 10/16/08 7:47 AM Page 5 6 ASSEMBLY Assembly tools required (not supplied) • Phillips screwdriver ATTACHING HANDLE TO UNIT (FIGURE A) • Align the D-handle with the main body of the unit and push it down until it is fully seated as shown in figure A. • Remove the phillips head screw from the plastic bag. • Insert the screw into the hole indicated by the arrow in figure A. • Tighten screw securely using a phillips screwdriver. CHARGING BASE (FIGURE B) • Place the charging base (6) on the floor, convenient to an electrical outlet. The PSV1800 stores and charges in the base whenever it is not in use. WARNING: Falling/Tripping Hazard. Do not place charging base on any elevated surface. The product is designed to be placed into and removed from the charging base when it is sitting on the floor convenient to an electrical outlet. OPENING THE VACUUM (FIGURES C - H) • To open the vac for use, lift it from the charging base (6) (figure C). • Push back the pivot lock trigger (3) on the handle and rotate the vacuum head (figure D). N O 11 12 12 M 10 90528647 01 PSV1800 PIVOT CRDL VAC 10/16/08 7:47 AM Page 6 90528647 01 PSV1800 PIVOT CRDL VAC 10/16/08 7:47 AM Page 7 • Release the pivot lock trigger (3) to lock the vac in any of the three different working positions (figures E,F & G). • Figure H illustrates a typical application of vacuuming under furniture and other hard to reach places. OPERATION • Before first use, the battery must be charged for at least 21 hours. • Place the appliance on the charging base (6) whenever it is not in use. CHARGING THE BATTERY (FIGURE I) • Make sure that the appliance is switched off. The battery will not be charged with the on/off switch (4) in the on position. • Place the appliance on the charging base as shown. • Plug in the charger. The charging indicator (5) will be lit. • Leave the appliance to charge for at least 21 hours. SAFETY WARNINGS AND INSTRUCTIONS: CHARGING • While charging, the charger may become warm. This is normal and does not indicate a problem. • The appliance can be left connected to the charger indefinitely. The charging indicator (5) will be lit as long as the appliance is connected to the plugged-in charger. • Do not charge the battery at ambient temperatures below 39° F (4 °C) or above 104° (40 °C). SWITCHING ON AND OFF (FIGURE J) • To switch the appliance on, slide the on/off switch (4) forward to the 1st position (vacuum only). • For vacuuming with beater bar operation slide the on/off switch forward to the 2nd position. • To switch the appliance off, slide the on/off switch back. CLEANING AND MAINTENANCE CAUTION: Regularly clean the filters (9 & 10). CLEANING THE DUST CONTAINER AND FILTERS (FIGURES K - N) The filters are re-usable and should be cleaned regularly. • Press the release latch (1) and open the container door (2) (figure K). • Remove the filters (9 & 10) (figures L & M). • Empty the dust container. • Brush any loose dust off the filters. • Wash the filters in warm, soapy water. • Make sure that the filters are dry. A section (11) of the unit can be removed to aid cleaning should the product become blocked resulting in a loss of suction (figure N). • Remove the section using a flat bladed screwdriver (figure N inset) to release the front clip features. Once released, the section will pivot free of the main assembly to give...