. Walk through the coverage Ball area noting where you are Joint when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps. . Adjust the RANGE as needed. RANGE set too high may increase false triggering. . Secure the sensor head by tightening the clamp screw. Do not overtighten the screw. . Set the amount of ON-TIME you want the lights to stay on Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage after motion is detected (1, 5, or 20 minutes). . Set the DUAL LIGHT LEVEL switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn). SPECIFICATIONS Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost [varies with surrounding temperature]. Sensing Angle. . . . . . Up to 240° Electrical Load. . . . . . Up to 300 Watts Incandescent Maximum [Up to 150 Watts Maximum each lamp holder.] Power Requirements. 120 VAC, 60 Hz Operating Modes. . . . TEST, AUTO, and MANUAL MODE Time Delay . . . . . . . . 1 , 5, 20 minutes Dual Light Level . . . . Off, 3, 6 Hours, Dusk-to-Dawn Atlas Lighting Products, Inc. reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. Sensor MotionMotion Least Sensitive Most Sensitive 598-1094-01 -3 TROUBLESHOOTING GUIDE If you experience a problem with your Light Control, first follow this guide. For additional assistance write to: Atlas Lighting Products, Inc. • Customer Service Department • P.O. Box 2348 • Burlington, NC 27216 SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE 1. A flood lamp is positioned too close Lights will not 1. Light switch is turned off. Lights stay on come on. 2. Flood light is loose or continuously. to the sensor or pointed at nearby burned out. objects that cause heat to trigger the 3. Fuse is blown or circuit breaker sensor. (Reposition the lamp away is turned off. from the sensor or nearby objects). 4. Daylight turn-off is in effect (Re2. Light Control is pointed toward a heat check after dark). source like an air vent, dryer vent, or 5. Incorrect circuit wiring, if this is a brightly-painted heat-reflective surface. new installation. (Reposition sensor.Reduce Range). 6. Re-aim the sensor to cover de3. Light Control is in Manual Mode. sired area. (Switch to Auto.) Lights come on 1. Light Control may be installed in Lights flash 1. Heat or light from the lamps may be in daylight. a relatively dark location. on and off. turning the Light Control on and off. 2. Light Control is in Test. (Set (Reposition the lamps away from the control switch to an ON-TIME sensor). position). 2. Heat being reflected from other objects may be affecting the sensor. Lights come on 1. Light Control may be sensing (Reposition sensor). for no apparent small animals or automobile traf 3. Light Control is in the Test mode and fic (Re-aim sensor). reason. warming up. (Flashing is normal un 2. Range is set too high. (Reduce der these conditions. Turn Boost off.) Range). 4. Light may be leaking through the 3. Dual Light Level is on. floodlamp reflectors. (Make sure the metal lamp protectors are installed). Lights flash 1. Sensor is detecting its own lights once, then (Reposition lamps to keep area be- stay off in low sensor relatively dark). Manual Mode. FIVE YEAR LIMITED WARRANTY Atlas Lighting Products, Inc. warrants against defects in materials or workmanship for a period of five years from the date of purchase for use, and agrees to repair or, at our option, replace a defective unit without charge for either parts or labor. IMPORTANT: This warranty does not cover damage resulting from accident, misuse of abuse, lack of reasonable care, the affixing of any attachment not provided with product, alteration of any attachments factory installed, loss of parts or subjecting the fixture to any but the specified electrical service. This warranty does not cover failure of the bulb due to accidents, abuse, misuse, vandalism, power surges, and acts of nature such as lightning damage. No responsibility is assumed for any special incidental or consequential damages. Damages occurring during transit are not covered by this warranty-including UPS shipments. To obtain warranty service, mail sales receipt as proof-of-purchase, date and a brief explanation of the nature of the defect, to the address listed below. You will receive, by mail, a Return Goods Authorization number and full instructions for returning defective merchandise. All returned goods must be accompanied by a Return Goods Authorization number issued by Atlas Lighting Products, Inc. NOTE: No other warranty, written or verbal, is authorized by Atlas Lighting Products, Inc. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incide...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - Guardian Pro MLGC240W (476.77 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien