Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung American Standard, modell 2425L/V - LHO

Hersteller: American Standard
Dateigröße: 1.84 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


ROUGHING-IN REFERENCESSAVONA (MODEL 2901L)CORNER (MODEL 6060L / V) 7" (178mm) 76-3/4" (1949mm) 54-1/2" (1384mm) 65-3/8" (1661mm) 3" (76mm) 7" (178mm) 15" (381mm) 5-5/8" (143mm) 17-3/4" (451mm) 10" (254mm) 13-3/4" (349mm)CUT OUT IN FLOOR FOR DRAIN72" (1829mm) 44" (1118mm) 3" (76mm) 12" (305mm) 8" (203mm) RECOMMENDED FITTING LOCATION 64 X 279mm (2-1/2 X 11) . 6" (152mm) 11-1/2" (292mm) 5-1/2" (140mm) CADET CORNER (MODEL 2775L) 1524mm(60") 70mm REF. (2-3/4) 165mm(6-1/2) 279mm(11") 229 X 305mm(9" X 12") CUTOUT INFLOOR FORDRAINOUTLINE OFCUTOUT2159mm(85") 1080 mm(42-1/2") C/L1524mm(60") 1076mm(42-3/8") 1080mm(42-1/2") PUMPC/L OF DRAIN OUTLET5X42 (MODEL 2805L) 1524mm(60") INTEGRALFITTING DECK762mm(30") 1067mm(42") PROVIDE ACCESSTO PUMP FORSERVICE ON ALLINSTALLATIONS C/L OFDRAIN19mm(3/4") PUMP305mm(12") 152mm(6") PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONSRECOMMENDED FITTING LOCATION 64 X 330mm (2-1/2 X 13") OUTLINE OF CUTOUT 1486mm x 1029mm (58-1/2" x 40-1/2") 178mm x 381mm (7" x 15") FLOOR CUTOUTELLISSE (MODEL 2711L) 1829mm(72") 927mm(36-1/2")OUTLINE OF CUTOUT1791 X 1181(70-1/2" X 46-1/2") C/L OFDRAIN102mm(4") PUMP305mm(12") 1219mm(48") 229mm x 356mm(9" x 14") FLOORCUTOUTRECOMMENDED FITTING LOCATION 64 X 279mm (2-1/2" X 11") OPTIONAL DECK FITTING AREA GRAB BAR FITTING AREAPROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS REMINISCENCE (MODEL 2908L / LA) x 305mm( X 1 ) FLOORCUTOUT mm REF. ( -1/ ) 1 7 mm( ") PUMP 1 mm(3 ") 57mm(1 ) 330mm(13") INTEGRALFITTING DECK15 mm( ) OUTLINE OF CUTOUT C/L OF DRAIN OUTLETPROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONSCADET 6 x 36 (MODEL 2773L) RECOMMENDED FITTING LOCATION X 330mm ( -1/ x 13") FOR PIER OR ISLANDINSTALLATIONS ONLYALT. FITTINGLOCATION #11 mm(7 ) 0 mm(35-3/ ) OUTLINE OF CUTOUT 17 1 mm x 70 mm(70-1/ X 3 -1/ ) 5 mm(17-7/ ) mm( ) 305 mm(1 ) 57mm( -1/ )( ) JETSCUTOUT IN FLOORFOR DRAINPUMPFINISHEDWALL1 mm(3/ ) mm( ) C/L OF DRAIN( ) AIR VALVESPROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONSCADET 6 x 42 (MODEL 2774L / LA) C/L OF DRAINRECOMMENDED FITTING LOCATION X 330mm ( -1/ x 13") FOR PIER OR ISLANDINSTALLATIONS ONLYALT. FITTINGLOCATION #11 mm(7 ) 10 7mm( ) 533mm( 1) mm( ) 305 mm(1 ) 57mm( -1/ )( ) JETSCUTOUT IN FLOORFOR DRAINPUMPFINISHEDWALL1 mm(3/ ) mm( ) ( ) AIR VALVESPROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONSOUTLINE OF CUTOUT 17 1mm x 10 mm(70-1/ X 0-1/ ) DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z1 .1 AND A11 .1 .7. ROUGHING-IN REFERENCES INSTALLATION AND FRAMING INSTRUCTIONSThe variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening. TYPICAL PIER TYPE INSTALLATIONAS DESIREDFCUTOUTAS DESIREDGCUTOUTC ( 10 mm) 1 (305 mm) MOUNTING SURFACEWATERPROOF SEALANTBATHTYPICAL RECESS INSTALLATION ( 10 mm) 1 (305 mm) CEDWLEVELINGSTRINGERSTILETILEBEADSTRIPLEVELING STRINGER 1 x (not for support) BATHADHESIVESEALANTWALLBOARDNOTE: Tile bead kit not included and must be purchased separately. CTYPICAL INSTALLATIONFIGURE 1 This bath must be supported along its entire bottom. Use mortar as bedding material (do not use sand or foam). Apply enough mortar to support the complete bottom of the bath. After the mortar has been poured, and before it sets, position whirlpool or bath within recess until the rim is leveled against the leveling stringers (see "Typical Recess Installation") shown below. The rim of the bath must not support weight. Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must be self-supporting if it contacts the deck of the bath. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base consisting of cement, mortar, or grout will help provide a solid and secure installation. 3. Install drain components to the whirlpool following the drain installation instructions. Before replacing your whirlpool for final installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing and Table 1 for suggested opening size (shadowed) and location dimensions. The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout in the floor. The floor structure beneath the bath must be able to support a total weight of bath, water, and bather. Refer to Table 1 under total weight for your model. For Models: 2425L/...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - 2422L/LA/V/VA (1.84 mb)
Andere Home Zubehör - 2711L (1.84 mb)
Andere Home Zubehör - 2425L/V -RHO (1.84 mb)
Andere Home Zubehör - 2645L (1.84 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien