Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.4 ( )

Anleitung Desa, modell Motion Sensing Halogen Fixture 5525

Hersteller: Desa
Dateigröße: 259.23 kb
Dateiname: 598-1311-00.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: Plastic Hanger 6 Screws Gasket (3 sizes included) 1 Halogen Lamp Sensor 3 Wire Connectors Light Control Mounting Strap Mounting Bolt Rubber Plug Light Shield Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualifi ed electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. OPERATION Mode: On-Time 5 Seconds1, 5, or 10 Min Works: Day Night Test xx Auto x Manual Until Dawn* x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST 10 5 1 TEST ON-TIMEPut the ON-TIME switch on the bottom of the sensor in the TEST position. AUTO ON-TIME 10 5 1 TEST Put the ON-TIME switch in the 1, 5, or 10 minute position. MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one sec 1 Second OFF ond then back on to toggle between then... AUTO and MANUAL MODE. Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position. ... back on. Mode Switch Summary TEST Move ON-TIME Switch to 1, 5, or 10 minutes AUTO Flip light switch off for one second then back on* MANUAL MODE * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. © 2007 DESA Specialty Products™ 598-1311-00 INSTALLATION BULB INSTALLATION For easy installation, select an existing light with a wall switch for replacement. For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. CAUTION:To Avoid Fire Or Burn Hazards: • Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures. • Keep fixture at least 1" (2.5 cm) from combustible materials. Do not aim at objects closer than 3 ft. (1 m). • Use only T3, 250W (max.) tungsten halogen 120 VAC lamps. . Note the position of the various parts of the fi xture for the type of installation for your application and adjust the lamp head and sensor as shown below. Wall Mount Eave Mount Lens Retainer Light Shield, with opening at this side Lens Retainer For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the Light Shield and stick on as shown below. For eave mount only: . Swing the sensor head towards the clamp screw joint. Controls Clamp Screw . Then rotate the sensor head clockwise 180° so the controls face down. Light Shield Opening Controls Controls If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. . When relamping, turn power off and let the fixture cool. . Remove glass cover and remove the old bulb by pushing the bulb towards the socket indicated on the metal reflector. . To insert the new bulb, follow the instructions printed on the metal reflector. . Check that the bulb is seated properly. . Reinstall the glass cover. WIRE THE LIGHT CONTROL WARNING: Turn power off at circuit breaker or fuse. . Remove the existing light fixture. . Install mounting strap to junction box using screws appropriate for your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Thread all fixture wires through the large holes in the gasket as shown. . Connect the junction box wires to the light fixture wires as shown.Twist together and secure with wire connectors. Mounting Strap White to WhiteBlack to Black Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire. Gasket Mounting Bolt Rubber Plug MOUNT THE LIGHT CONTROL . Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt. . Push the Rubber Plug firmly into place. . If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. 2 598-1311-00 TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes. . Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. ON-TIME RANGE 10 5 1 TEST MIN MAX Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets o...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien