Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Blodgett, modell KTT-E Series

Hersteller: Blodgett
Dateigröße: 450.36 kb
Dateiname: KTT-E-man.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment. This manual should be retained for future reference. ADEQUATE CLEARANCES MUST BE MAINTAINED FOR SERVICING AND PROPER OPERATION. DO NOT ATTEMPT TO OPERATE THIS UNIT IN THE EVENT OF A POWER FAILURE. NOTICE: Contact the factory, the factory representative or local service company to perform maintenance and repairs. Intended for commercial use only. Not for household use. TABLE OF CONTENTS DESCRIPTION PAGE IMPORTANT NOTES FOR INSTALLATION AND OPERATION ........................................ 2 SERVICE CONNECTIONS ................................................................................................. 4 1.0 INSTALLATION INSTRUCTIONS ................................................................................ 5 2.0 INTRODUCTION .......................................................................................................... 7 3.0 OPERATION INSTRUCTIONS .................................................................................... 8 4.0 CLEANING INSTRUCTIONS ..................................................................................... 10 5.0 TROUBLESHOOTING ............................................................................................... 11 APPENDIX A Material Safety Data Sheet ........................................................................... 12 SERVICE CONNECTIONS FESAFETY RELIEF VALVE4 [102] 10 [254] 12.5 [318] HJ1.25 [32]LKG14.50 [368] A IDBCD4X WELD NUTS5/16-18UNC18 [457] 2.25 [57] DIMENSIONS ARE IN INCHES [MM] ELECTRICAL CONNECTION TO BE AS SPECIFIED ON DATA PLATE6 gallonsCAPACITY10 gallons12 gallonsMODELKTT-10EKTT-12EKTT-6E266102471128660UNITS45 litres23 litres38 litresmmmmmmCAB43238136514.3830540616121715DIMENSIONSD93736.8834.8885133.5886FE17.2515.2538743826.2522.25565667H286862730762711 G1144.50KJ1086.121564.2514.7531412.383751174.621054.1210254L32412.7512.75324inchesinchesinchesELECTRICAL CHARACTERISTICSPHASE1KTT-10E & KTT-12EKTT-6E133MODEL208V36.057.633.320.834.154.631.519.7220V415VAMPS PER LINE31.318.128.950.0240V18.311.4380V480V14.516.710.49.012.07.5kWN/AN/AN/AN/AN/AN/A 1.0 INSTALLATION INSTRUCTIONS Immediately after unpacking, check for possible shipping damage. If the kettle is found to be damaged, save the packaging materials and contact the carrier within 15 days of delivery. 1. The kettle must be installed in accordance with: 2. State and/or local codes. 3. In the USA, the National Electrical Code, ANSI/NFPA-70 (latest edition). In Canada, the Canadian Electrical Code, Part 1, CSA Standard C22.1 (latest edition). 4. Position appliance on counter allowing sufficient rear clearance from wall to tilt freely and completely without obstruction. 5. Mark four corner locations of appliance base. 6. Remove appliance from counter and locate position of 4 holes as per Figure 1. Drill four 7/16" diameter holes. 7. Apply a continuous bead of Silastic or other equivalent sealant along the complete perimeter edge of the appliance base. 8. Use 5/16-18 Hex Cap Screws with suitable flat washers to bolt down. Screw length must be 1-1/4 long plus counter top thickness. 9. Wipe off excess sealant. 10. A control box with power supply equivalent to Electrical Rating of appliance should be located conveniently nearby. WARNING: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. 1.0 INSTALLATION INSTRUCTIONS (Continued) WARNING: Disconnect electrical power supply and place a tag at the disconnect switch to indicate you are on the circuit. 1. A waterproof electrical connection for power supply to console housing must be provided. 2. Ground appliance to terminal provided inside console housing. 3. Turn power ON and check for proper operation. FIGURE 1 2.0 INTRODUCTION DESCRIPTION Models KTT-6E (6 gallon capacity) and KTT-10E (10 gallon capacity) and KTT-12E (12 gallon capacity) electrically powered, self-contained, countertop, tilting kettles. Each model has a jacket of double-wall construction forming a sealed reservoir around the lower two-thirds of the kettle. The reservoir is charged with distilled water. Kettles are equipped with a removable electric heating element and controls, including a low water cutoff device for protection of the heating element. All models are of identical construction, except for kettle size and element heating capacity. BASIC FUNCTION Self-contained kettles operate by generating steam in the kettle reservoir. The sequence of operation is as follows: 1. Operator turns the power switch to the ON position a...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien