Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Grindmaster, modell Insulated Decanter Brewer AMW B-Series

Hersteller: Grindmaster
Dateigröße: 1.55 mb
Dateiname: e869a20c-230b-44d4-a01b-d340a957c586.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• An approved backflow prevention device, such as a double check valve to be installed between the machine and water supply. A 1/4” male flare adapter is provided. Installation to a water filter system is recommended to prevent lime and scale build-up in the machine. • Water pipe connections and fixtures directly connected to portable water supply shall be sized, installed and maintained in accordance with federal, state and local codes. • Flush the water line to purge any debris from the supply line. For 120V, 15A or 20A Service Connect a 1/4” pressurized water line to the 1/4” male connection (2 Wire + Ground) (on rear of brewer) and turn the water supply on. a) Minimum water pressure to the machine: 30 psi b) Maximum water pressure to the machine: 80 psi NOTE: Single head machines may be used without a pressurized water supply. (See Pour-Over Mode section) ELECTRICAL CONNECTION NOTE: Wiring connections should be performed by a qualified technician. (Refer to serial tag to verify model number of your machine) For 120/208-240V, 20A Service (3 Wire + Ground) • Remove front panel. • Connect electrical service through rear of machine to terminal block (inside front panel) marked L1, N, and L2. (See Figures A and B) • On dual volt units, flip voltage switch (inside front panel next to terminal block) to 120V for 120 Volt service or 240V for 120/208, or 120/240 Volt service. (See Figures A, B and table below) • Re-install front panel. • Turn on (plug-in) electrical service to brewer. • Water tank will fill after a 7-second delay. The machine will make a hissing sound when this occurs. On single head models, allow approximately 1.5 minutes for the brewer to fill. On two head models, allow approximately five minutes for the brewer to fill. NOTE: If water supply is inadequate or not connected, display will read “P-O” after 4 minutes of fill time (Refer to Pour-Over Mode section). If Fill Cycle times out and display reads “P-O” before tank is full, turn unit OFF then ON again to reset and continue filling. • The tank will begin heating slightly before machine fills. • Turn brewer on by pressing ON/OFF switch in front of machine. (Light will illuminate) • The brewer settings can be adjusted through the front touch pad. (Refer to Adjustments section) • The water will be hot and the brewer will be ready to brew when “READY” light illuminates. • Set Brew volume. (Refer to Setting Brew Volume section) POWER REQUIREMENTS: (Refer to serial tag for voltage to be supplied.) Figure A L1 N L2 CONNECT NEUTRAL (N) TO MIDDLE CONNECT HOT (L1) TO LEFT SIDE CONNECT GROUND TO SCREW ON DUAL VOLT UNITS, FLIP SWITCH TO “120V” Figure B L1 N L2 CONNECT HOT (L2) TO RIGHT SIDE CONNECT NEUTRAL (N) TO MIDDLE CONNECT HOT (L1) TO LEFT SIDE CONNECT GROUND TO SCREW ON DUAL VOLT UNITS, FLIP SWITCH TO “120V” Applied Volts Models Watts Amps NEMA Plug Cord AWG Connections 120 B-3, B-3WL, B-3WR 1800 15 5-15P, 5-20P for CUL 3X14 Hot to L1 Neutral to N Ground to ground screwB-SAP, B-ID 1780 14.9 120/208 B-3, B-3WL, B-3WR 2920 14.1 L14-20P 4X12 Hot to L1 Neutral to N Hot to L2 Ground to ground screw B-SAP, B-ID, B-DAP, B-DGP 2620 12.6 B-6 5110 24.6 L14-30P 4X10 B-DAP, B-DGP (30A) 4510 21.7 120/240 B-3, B-3WL, B-3WR 3800 15.9 L14-20P 4X12 Hot to L1 Neutral to N Hot to L2 Ground to ground screw B-SAP, B-ID, B-DAP, B -DGP 3500 14.6 B-6 6600 27.5 L14-30P 4X10 B-DAP, B-DGP (30A) 6000 25 Page 2 B-SERIES FACTORY SETTINGS (for each dispense head) • Tank temperature is set at 200 degrees F. • Brew time is pre-set at 2:20. (Volume/time to be set on-site) • Pulse Brew is set for 1 pulse, 20 sec on, 20 sec off. • Warmer Energy Savings mode is set for 60-minutes. (“OFF” for models without warmers) • Low Temp / No Brew option is set to “OFF” or disabled. • Pour over setting override is set to “no” or plumb in. • Settings lock-out jumper on controller is set in “unlock” position. ADJUSTMENTS: Refer to B-Series Programming Chart on page 5. NOTE: Set each dispense head individually on two head models with two controllers and serial numbers A166225 and lower (without a -P suffix). Tank temperature must be set to the same setting on both heads in order for the unit to operate properly. Tank Temperature: Left display controls this. • Press-and-hold both “up” and “down” arrows for 5 seconds. • The display will indicate either “d F” or “d C”. (Fahrenheit or Celsius) • Press up or down arrow to change from one scale to the other. • Press “BREW” button to accept and proceed to the next setting. • The display will read temperature value in the scale previously selected. • Press up or down arrow to change temperature value. • Press “BREW” button to accept and proceed to the next setting. Brew Time: • The display will read “br ”. (brew time) • Press “BREW” button to proceed to the next setting. • The display will read the set brew time in minutes and seconds. (ex: 2.20) • Press up or down arrow to change time value. • Press “BREW” button to accept and proceed to the next setting....


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien