Anleitung Amana, modell PGB58B

Hersteller: Amana
Dateigröße: 1.11 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


16 Air Circulation Blower Gas Valve Ignitor Pressure Switch (N.O. Contacts) Combustion Blower Thermostat ON OFF OPEN CLOSED ON OFF CLOSED OPEN ON OFF ON OFF Seconds 0 34 38 110 0 90 Thermostat ON Gas Valve OpensIgnitor OFF Air Blower ON Thermostat OFFCombustion ProductPurge Ends. Air Blower OFFCombustionBlower OFF Figure 12 Timing Chart for Normal Robertshaw Operation (PGB & PGC) On Indoor Fan Off Outdoor Fan On and Off Compressor On Thermostat Off Seconds 0 15 0 45 (approx.) (approx.) Figure 13A PGB Timing Chart for Normal Cooling Operation On Indoor Fan Off Outdoor Fan On and Off Compressor On Thermostat Off Seconds 0 30 0 30 (approx.) (approx.) Figure 13B PGC Timing Chart for Normal Cooling Operation 17 X. Heating Sequence of Operations PGB & PGC) Normal Sequence of Operation - Heating See Figure 12 1. Thermostat calls for heat. The combustion blower is immediately energized. 2. The pressure switch contacts transfer. 3. The ignitor is energized and allowed to preheat for 38 seconds. 4. The gas valve is energized delivering gas to the burners and starting combustion. 5. The control checks the signal from the flame sensor. Gas flow will continue only if a proper signal is present within seven seconds after the gas valve opens. As soon as flame is proven, the ignitor is de- energized. 6. The unit will continue to fire while the helical fan control heats up. The fan control will start the main circulating air blower approximately 75 seconds after the gas valve opens (this time may vary depending on the control setting). 7. The furnace will deliver heat to the conditioned space until the thermostat is satisfied. 8. The gas valve and combustion blower will be de- energized when the thermostat opens. 9. There is a 90 second delay (approximate) before the main air blower stops. This allows any additional heat in the heat exchanger to be transferred to the conditioned space. XI. Cooling Sequence of Operations PGB Normal Sequence of Operations - Cooling See Figure 13A 1. Thermostat calls for cooling. The compressor and outdoor fan are energized. 2. Approximately 15 seconds later, the fan time delay relay closes. The indoor fan now begins operation. 3. The unit will deliver cooling to the conditioned space until the thermostat is satisfied. 4. The compressor and outdoor fan will be de-energized when the thermostat opens. It is normal for the scroll compressor to produce a short burping sound at this time as its internal pressures are equalized. 5. Refrigerant will continue to flow through the capillary tube (sizes 24 to 42) until the high and low side pressures are approximately equal. Refrigerant will continue to flow through the thermal expansion valve until the high and low side pressures are approximately 50 PSI apart. 6. The indoor fan continues to run for approximately 45 seconds after the thermostat is satisfied. This allows additional cooling from the indoor coil to be transferred to the conditioned space. PGC Normal Sequence of Operations - Cooling See Figure 13B 1. Thermostat calls for cooling. The compressor, indoor fan, and outdoor fan are energized. 2. Approximately 30 seconds later, the indoor fan ramps up to full speed. 3. The unit will deliver cooling to the conditioned space until the thermostat is satisfied. 4. The compressor and outdoor fan will be de-energized when the thermostat opens. It is normal for the scroll compressor to produce a short burping sound at this time as its internal pressures are equalized. (The PGC48 has a piston compressor. All other PGC and PGB have scroll compressors.) 5. Refrigerant will continue to flow through the capillary tube (sizes 24 to 42) until the high and low side pressures are approximately equal. For the PGC48, 60 and PGB58 refrigerant will continue to flow through the thermal expansion valve until the high and low side pressures are approximately 50 PSI apart. 6. The indoor fan continues to run for approximately 30 seconds after the thermostat is satisfied. This allows additional cooling from the indoor coil to be transferred to the conditioned space. Then, the indoor fan ramps down in 30 seconds to the OFF condition. XIl. Startup and Adjustment Heating Startup General Information This furnace is equipped with an electronic ignition device which lights the burners. It also has a power vent blower to exhaust combustion products. On new installations, or if a major part such as the gas valve, pressure switch or fan/limit control has been replaced, the operation of the furnace must be checked. Check furnace operation as outlined in the following instructions. If any sparking, odors, or unusual noises are encountered, shut off electrical power and recheck for wiring errors, or obstructions in or near the blower motors. Various shipping materials must be removed before the indoor and outdoor fans can be operated. Heat Anticipator Setting The heat anticipator in the room thermostat must be correctly adjusted to obtain the proper number of heating cycles per hour ...

Dieses Handbuch ist für folgende Modelle:
Andere Küchengeräte - PGC(24-60)B (1.11 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien