Login:
Stimmen - 2, Durchschnittliche Bewertung: 3 ( )

Anleitung Magikitch'n, modell MKG48

Hersteller: Magikitch'n
Dateigröße: 820.01 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


CAUTION Only two of the four supplied casters are equipped with a locking feature. Install the griddle so that the two locking casters are at the front of the unit. The casters should be LOCKED before the unit is placed into operation. (See Figure 4). To mount the griddle to the stand, locate joining kit supplied with stand. The joining kit should include (2) rear mounting brackets, and (4) 1/2" mounting bolts. To mount the griddle to the equipment perform the steps on the following page: Figure 2 CAUTION The appliance must be level to perform properly. Failure to level unit may result in improper combustion and performance of the appliance. Figure 3 LIQUID TIGHT SEAL SIMULATED BASE ALL FOUR SIDES Installation MKG Series Gas Griddle L25-052 Rev. 0 (5/06) 7 1/2" BOLTS (4) BRACKET (2) MOUNT FLUSH TO FRONT (SUPPLIED) (SUPPLIED) NUTS & BOLTS INCLUDED WITH STAND REAR Figure 4 NOTICE The larger units have 6 threaded receiving holes, but require only the four 1/2" bolts on each corner to mount the griddle. 1. Remove (4) existing 1/4-20 nuts and bolts from the rear corners of the equipment stand. 2. Align the 2 bolt holes on the rear corners of the stand with the 2 bolt holes on the rear mounting brackets. Orient the brackets as shown in Figure #4 on this page. 3. Install the provided rear mounting brackets (2) to the rear corners by using the existing 1/4-20 hardware that were removed in step 1, tighten securely. 4. Carefully place the griddle on the equipment stand. 5. Once the griddle is on the stand, position the griddle on the stand so that the front edge of the base is flush with the front of the equipment stand. If the griddle is the only appliance to be mounted on the stand, then both sides of the griddle should be flush with the sides of the equipment stand. 6. When positioned properly, the threaded receiving holes in the griddle base should be aligned with mating clearance holes at the front of the equipment stand, and with the clearance holes in the rear mounting brackets. Install the provided 1/2" bolts and tighten securely. 1.5.4. Leveling Instructions NOTICE Equipment stands are shipped from the factory with the legs or casters set to “Zero”. Units should be leveled at time of installation, failure to do so could cause the griddle to operate improperly. 1. Identify the end or corner of the stand that needs to be raised, remove the weight load from the caster or leg to be leveled. 2. Legs- using a wrench, or pliers turn the leg bullet, See Figure 5, CCW to raise the height of the equipment stand. There is .” to .” of adjustment. Casters- (For Stands shipped after May 2006) Using a Flat Head screwdriver, loosen the set screws of the caster to be leveled, See Figure 5.Turn the collar of the caster CCW to raise the height of the equipment stand. There is .” to .” of adjustment. After leveling adjustment is complete, re-tighten set screws. 3. Repeat Step 2 for legs or casters that require leveling. 4. Check the levelness of the equipment, if necessary Repeat steps 1, 2, and 3. NOTICE This appliance may only be installed with casters provided by the manufacturer. When installed with casters, a gas connection complying with ANSI Z21.69/CGA-6.16 and a quick disconnect device complying with ANSI Z21.41/CAN 1-6.9. It must also be installed with a restraining device to guard against putting any strain on the gas connections when the unit is moved. Figure 5 Installation MKG Series Gas Griddle 8 L25-052 Rev. 0 (5/06) 1.6. Final Gas Connection A properly installed gas supply system will deliver adequate pressure (7 to 8 inches w.c. for natural gas, 11 to 12 inches w.c. for propane) to all appliances connected to the line, operating at full demand. 1.6.1. Regulator Assembly An adequate gas supply is important for the appliance to operate properly. Undersized lines or lowpressures will restrict the volume of gas required for satisfactory performance. A steady supply pressure between 7” and 8” w.c. for natural gas or 11” to 12” for propane gas is required. With all gas appliances operating simultaneously, the manifold pressure on all gas appliances should not show any appreciable drop. Fluctuations of more than 25% on natural and 10% on propane gas will create pilot problems and affect burner operating characteristics. Contact your gas company for correct supply line sizes. After connection, a certified gas service agent should check all newly installed equipment for correct gas pressure. The unit should be connected ONLY to the type of gas for which it is equipped. Check the type of gas on the Data plate, see section 1.1 of this manual. Figure 6 1. The gas input regulator for your new appliance have been installed at the factory, See Figure 6 for the location of the regulator manual shut off valve equipped on your appliance. Using a regulator other than the one supplied with the unit will void the warranty. 2. The manifold pressure must be maintained at the pressure marked on the Data plate. For appliances equipped w...

Dieses Handbuch ist für folgende Modelle:
Andere Küchengeräte - MKG24 (820.01 kb)
Andere Küchengeräte - MKG36 (820.01 kb)
Andere Küchengeräte - MKG60 (820.01 kb)
Andere Küchengeräte - MKG72 (820.01 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien