It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician. To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. (2) Drain water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. (4) The heater circuit will automatically reset in less than 15 minutes. (5) Restore power to the heater. (6) Whirlpool bath is now ready to use. 754532-100 Rev. A 32 REMOTE BLOWER LOCATION OPTION IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical. NOTE: Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired position of air blower. Follow all instructions listed below. 1. TYPICAL VIEW NOTE: Installing the blower in a remote location will reduce the system efficiency. NOTE: Relocating a blower motor still requires a service access for the blower. NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel cable (754025-0073A), a longer flexible blower hose (753960-2030A), and up to two lighting cable extensions for combo models (754512-0070A). A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location. Electrical connections should be performed by a licensed electrician. The blower motor must be located within 12 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes. Disconnect the blower from the flexible hose as shown in photo 2. Do NOT remove the check valve manifold that is mounted to the underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in 2. 2. TYPICAL VIEW Do NOT move check valve manifold Replace the flexible hose shown in photo 2 with the longer flexible hose (P/N 753960-2030A) using the existing hope clamps. NOTE: Do NOT remove the original cable coming out of the blower. Instead, plug the longer cable (P/N 754025-0073A) into the existing cable that is coming out of the blower as shown in photo 3. Then plug the remaining end of the longer cable into the control panel which remains on the tub wall. TO CONTROL PANEL TO BLOWER 3. 754025-0073A CABLE EXISTING (INCLUDES ADAPTER CABLE BOX SHOWN) REMOTE BLOWER LOCATION OPTION (continued) FOR THE COMBINATION WHIRLPOOL / AIR BATH CONFIGURATIONS ONLY: Up to two additional control box extensions (P/N 754512-0070A) are required as shown in photo 4 (below). Simply extend the cables going to the blower by adding in the extension cables. Be careful not to damage the cable connections and never plug in cables while power is applied to blower and/or pump. PUMP LONGER CONTROL PANEL CABLE CONTROL PANEL (754025-0073A) 4. LIGHTS CONTROL BOX EXTENSIONS BLOWER (754512-0070A) Operation: Single Speed Whirlpool AIR SWITCH ELECTRONIC SWITCH BATHING: • Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater, it will automatically maintain the water temperature. • IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow. • IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump. • IMPORTANT: Water level must be ...

Dieses Handbuch ist für folgende Modelle:
Bathroom Zubehör - 2664 (1.69 mb)
Bathroom Zubehör - 2934 (1.69 mb)
Bathroom Zubehör - 2935 (1.69 mb)
Bathroom Zubehör - 2938 (1.69 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien