Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Bacharach, modell True Spot

Hersteller: Bacharach
Dateigröße: 29.55 kb
Dateiname: ae42fc76-604c-4fe0-a629-4926ad9db712.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Too much smoke is one of the most common causes of excessive fuel usage and expensive service requirements. That is precisely why the smoke test is an indispensable part of any oil burner service job; and with the True Spot, an accurate smoke reading takes less than a minute. The True Spot smoke test method has long been recognized as the accepted standard for oil burner smoke tests. It is used by Underwriters' Laboratories in approval testing of oil burners; and it is the test method specified in the Installation Standards of the National Oil Fuel Institute by U.S. Department of Commerce, Testing materials (D2156-65), and German Standard DIN 51-402. ORDERING INFORMATION PART NO. DESCRIPTION 21-7006 True Spot Smoke Test Kit 21-7012 Test Pump 21-0018 Smoke Scale 21-0040 Lubricant 21-0019 Filter Paper Sheets (40 strips)* *Note: A spare kit containing replacement scale and filter paper is available; order item # 21-0020. CO Indicator Kits Carbon Monoxide Indicator Monoxor® Indicator A quick, easy to use instrument that measures carbon monoxide by simply drawing an air sample through a chemical reagent in a glass indicator tube. If carbon monoxide is present, a stain appears in the indicator tube; the length of the stain is measured against a built-in scale to determine the CO percentage or parts per million (ppm). Monoxor Detector The Monoxor Detector is also fast and simple to operate. An air sample is drawn through a detector tube containing an indicating gel; if a stain forms after one pump stroke, the CO concentration is 300 ppm or higher. If it appears after two strokes, the concentration is 100 to 300 ppm. If no stain appears, the concentration is less than 100 ppm. ORDERING INFORMATION ITEM NO. ITEMS RANGE SAMPLE PUMP (Incl. Scale & Orifice A) SCALE TUBES (12 per carton) TUBE CAPS (6) FLUE GAS SAMPLING ASSEMBLY 19-0240 19-0241 Monoxor Indicators 0-0.2% 0-0.5% 19-0242 19-0243 19-0014 19-0015 19-5010 19-5015 19-0001 19-0001 None None 19-0245 19-0244 Monoxor Gas Test Kit 0-0.2% 0-0.5% 19-0242 19-0243 19-0014 19-0015 19-5010 19-5015 19-0001 19-0001 11-7045 11-7045 19-7021 Monoxor Detector including pump, one carton of 12 indicator tubes (19-5002) and a carrying case 19-5005 Monoxor Detector Kit (19-7021), as above, plus Flue Gas Sampling Assembly (11-7056) 20 1.800.736.4666 BACHARACH...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien