Anleitung Zusammenfassung


The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxide, etc.) With 18 alarms interconnected, it is still possible to interconnect up to a total of 6 remote signaling devices and/or relay modules. I M P O R TA N T: Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms and accessories as well as specified brands and models of interconnect compatible alarms. Connection of Kidde products to a non-specified m a n u f a c t u r e r ’s interconnect system, or connection with non- specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming, failure to alarm, or damage to one or all of the devices in the interconnect system. Refer to the User’s Guide supplied with each Kidde product for interconnect compatible models, brands, and devices. • When mixing models which have battery backup with models without battery backup, be advised that the models without battery backup will not respond during an AC power failure. • For more information about compatible interconnect units and their functionality in an interconnect system, visit our web site at: • The maximum wire run distance between the first and last unit in an interconnected system is 305 m (1000'). • Image 3 illustrates interconnection wiring. Improper connection will result in damage to the alarm, failure to operate, or a shock hazard. • Make certain alarms are wired to a continuous (nonswitched) power line. NOTE: Use standard CSA listed household wire (18 gauge or larger as required by local codes) available at all electrical supply stores and most hardware stores. 7 8 I n s t a l l a t i o n I n s t a l l a t i o n IMAGE 3 INTERCONNECT WIRING ROTATE TO MOUNT ORTO REMOVE IMAGE 4A IMAGE 4B BATTERYREMINDER TAB TAMPER-RESIST LOCKING PIN IMAGE 4C IMAGE 4D 9 10 I n s t a l l a t i o n Mounting CAUTION: This unit is sealed. The cover is not removable! • Pull the AC Quick-Connect wire harness through the centre hole in the mounting plate and secure the plate, making s u re that the mounting screws are positioned in the small ends of the keyholes before tightening (Image 4A). • (For models 1275CA and PE120CA) Press the battery reminder tab down into the battery compartment while inserting the battery (Image 4C). CAUTION: If the battery reminder tab is not held down in the battery compartment by the battery, the battery door will not close and the unit will not attach to the mounting plate. • Plug the AC Quick-Connect wire harness into the back of the alarm (Image 5), making sure that the locks on the connector snap into place. Push the excess wire back into the electrical box through the hole in the center of the mounting plate. ATTACHING THE AC QUICKCONNECT WIRE HARNESS IMAGE 5 • Alignment marks are provided on the edge of the mounting plate and the alarm. After installing the mounting plate, place the alarm onto the mounting plate, making sure the alignment marks are lined up. Twist the alarm in the direction indicated by the “ON” arrow on the alarm cover (Image 4B) until it locks in place. I n s t a l l a t i o n Battery Backup Models 1275CA and PE120CA with battery backup will not function without a properly installed battery. They are equipped with a battery lockout feature which prevents the battery door from closing if a battery is not installed correctly. See Maintenance section for additional information concerning battery installation. Testing • To ensure proper operation of models 1275CA and PE120CA with battery backup, press the Test button (without the AC power connected). All interconnected, battery backed-up alarms, should respond. CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms-length away from the unit when testing. • Tu rn on the AC power. The green LED power indicator should be lit when the alarm is operating from AC power. • For all models: C o n f i rm unit operation by pressing the Test button again. The smoke alarm is operating once AC power is applied, a f resh battery is installed (only for battery backup models 1275CA and PE120CA) and testing is complete. When the smoke alarm ionization sensor chamber senses products of combustion, the horn will sound a loud (85db) alarm until the sensing chamber is cleared of smoke particles. Alarm Tamper Resist Feature • To make the smoke alarm tamper-resistant, a locking pin has been provided in the bag with the screws and anchors. Using this pin will deter children and others from removing the alarm from the mounting plate. To use the pin, insert it into the hole in the side of the alarm after the alarm has been installed on the mounting plate (Image 4D). NOTE: The tamper-resistant pin will have to be removed in order to change the battery (models 1...

Dieses Handbuch ist für folgende Modelle:
Alarm - 1275CA (574.71 kb)
Alarm - 1235CA (574.71 kb)
Alarm - 1235CA (574.71 kb)
Alarm - 1275CA (574.71 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien