Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung LST, modell 16589

Hersteller: LST
Dateigröße: 107.1 kb
Dateiname: 17fa516f-6fdb-4d0f-9f72-73cfc284e578.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Therefore, it is extremely well suitable for the detection of fires which are difficult to detect with common smoke detectors - for example, alcoholic fires or gas flames. The detector is ideal for the following applications: • Pharmaceutical industry • Paint shops • Warehouses • Nuclear facilities • Tunnels three independent infrared sensors for different wavelengths and with an intelligent evaluation logic, the detector can safely distinguish between alarm situations and deceptive alarms. Therefore, it is particularly insensitive to disturbance sources such as sunlight, fluorescent lamps or electric arcs. The detector complies with EN 54-10, Class 1, which means it is suitable to detect flames up to a distance of 25m. The response delay of the detector can be selected in 4 steps between 1 and 8s. An alarm and a fault condition is signalled via two dry relay contacts. Conventional technology is used for alarm transmission to the fire detection control panel. The detector can be integrated into an ADM loop by means of a conventional zone module. A simple test of the detector can be carried out by means of the integrated optical self test function, which does not require additional tools. During this self test, a built-in infrared source simulates a fire situation which activates the detector. The detector has been designed for indoor and outdoor use. The optional Detector Mounting Bracket 7127 allows stepless horizontal and vertical adjustment for the easy adaptation of the detector to the required monitoring area. For use in explosion-hazardous areas, an Ex version of the flame detector is available on request. -~r&: U>CBI 0832-CPD-0595 Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52H4-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED ÍR3-1Ó589 DBL LST EN 0850.PDF • PAGE 1 Specifications Operating voltage 14 - 30VDC Current consumption at 24VDC max. 8mA (quiescent), 14mA (alarm) Monitored angle 9 O o Range max. 25m Spectral sensitivity E r-^ - LO r-^ o Contact rating of relay outputs max. 1A at 50VDC Ambient temperature -10°C to +55°C Dimensions W x H x D 108 x 142 x 82 (mm) Colour sky blue, RAL 5015 Weight 2kg Protection class IP65 Approvals LPCB 729a/01 0832-CPD-0595 Order number 243011 Order name Flame Detector/IR3 16589 Detector Mounting Bracket Material stainless steel Adjustment range vertical 0 to -45° Adjustment range horizontal ±45° Dimensions W x H x D 82 x 98 x 90 (mm) Weight 650g Order number 249141 Order name Detector Mounting Bracket/Flame Detector 7127 Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52H4-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED ÍR3-16589 DBL LST EN 0850.PDF • PAGE 2...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien