Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Eton, modell BAR388HGA

Hersteller: Eton
Dateigröße: 907.62 kb
Dateiname: BAR388HGA_M_OP.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at or on the warranty card for this product) for all inquiries instead. We Name: Oregon Scientific, Inc. Address: 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA Telephone No.: 1-800-853-8883 declare that the product Product No.: BAR388HGA Product Name: Wireless Weather Station with Temperature / Humidity Display and Self - Setting Atomic Clock Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. To set the alarm: 1. Press and hold ALARM for 2 seconds. 2. Press / to set hour / minute. 3. Press ALARM to confirm. indicates alarm is ON. To enable / disable the alarm: 1. Press ALARM to display alarm time. 2. Press ALARM again to turn alarm ON / OFF. To silence the alarm: • Press SNOOZE to silence it for 8 minutes. OR • Press any key except SNOOZE to turn the alarm off and activate it again after 24 hours. To set alarm ON / OFF: 1. Press and hold TEMP / HUMIDITY HI / LO . 2. Use and to select high / low temperature / humidity alarm. Press TEMP / HUMIDITY HI / LO to confirm. 3. Press / to set alarm ON / OFF and press TEMP / HUMIDITY HI / LO to confirm. 4. If alarm has been activated, use and to select the temperature / humidity. 5. Press TEMP / HUMIDITY HI / LO to confirm. To silence the hi / lo alarm: Press any key. The alarm resets automatically and will resound if the hi / lo temperature is recorded again. BAROMETER Barometer readings from the past 24 hours are stored by the main unit and used to provide weather forecast. To select barometer measurement unit: Press PRESSURE to toggle between mb and inHg. SPECIFICATIONS HEAT INDEX The heat index combines temperature and humidity data to describe the actual temperature felt. TYPE DESCRIPTION MAIN UNIT L x W x H WARNING HEAT INDEX MEANING 119 x 77 x 169 mm (4.7 x 3.0 x 6.7 in) SET ALTITUDE Strong risk of dehydration / sun stroke To ensure barometric readings are reliable set the altitude to reflect distance from sea level at your position. 1. Press and hold PRESSURE for 2 seconds. 2. Use and to set the altitude in 10 m (33 ft) increments from -100 m (-328 ft) to 2500 m (8202 ft). 3. Press PRESSURE to confirm. NOTE The maximum operating altitude for the barometer and weather forecast is 2500m (8202 ft). Extreme danger 54.5°C / (130°F) or above 249 g (8.8 oz) without battery Weight °C / °F Temperature unit 40.5 - 54°C (105 - 129°F) Heat exhaustion likely Temperature range -5°C to 50°C (23°F to 122°F) Danger Resolution 0.1°C (0.2°F) Extreme caution 32.2 - 40°C (90 - 104°F) Possibility of heat dehydration Clock frequency WWVB-60 Synchronization Auto or disabled 26.6 - 31.7°C (80 - 89°F) Possibility of heat exhaustion Caution Signal frequency 433 MHz Auto or manual (disabled) Clock 25% - 95% Humidity range • To display the heat index, press HEAT INDEX. • To toggle between current / maximum / minimum readings, press HEAT INDEX, then press CHANNEL to select channel 1-3 or indoor, followed by MEM. • To toggle between temperature / humidity and heat index display, press and hold HEAT INDEX for 2 seconds. Press HEAT INDEX again to stop this feature. NOTE If the heat index is below 80°F / 26°C, or the desired channel is not working, the heat index will display NA . WEATHER FORECAST 1% Humidity resolution This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius based on barometric pressure trend readings. Memory Min / Max relative humidity and temperature 2 minutes Alarm duration Snooze 8 minutes ICON DESCRIPTION HH:MM:SS HH:MM: Day of Week Clock display Clear 12 / 24 hour format Hour format Partially Cloudy Calendar MM / DD or DD / MM language selectable: E, D, F, I and S COMFORT ZONE Cloudy 3 x UM-3 (AA) 1.5 V batteries Power The comfort zone assesses the climate based on current temperature and humidity measurements. REMOTE UNIT L x W x H 92 x 60 x 20 mm (3.6 x 2.4 x 0.8 in) Rainy ICON TEMPERATURE HUMIDITY 62 g (2.22 oz) Weight Any > 70% 30 m (100 ft) unobstructed Transmission range TEMPERATURE AND HUMIDITY Temperature range -30°C to 60°C (-22°F to 140°F) 20 - 25°C (68 - 77°F) 40 - 70% To toggle temperature unit: Press °C / °F. To view outdoor sensors temperature readings: Press CHANNEL. To auto-scan between sensors: Press and hold CHANNEL for 2 seconds. Each sensor’s data is displayed for 3 seconds. To end auto-scan: Press CHANNEL or M...

Dieses Handbuch ist für folgende Modelle:
Wettermessung - BAR388HGA (907.62 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien