Anleitung Zusammenfassung
MODE: Change settings / display 3. CHANNEL: Switch remote sensor display 4. MEM: View current, maximum and minimum temperature / humidity 5. PRESSURE: Select pressure unit; set altitude 6. HEAT INDEX: Display heat index 7. TEMP / HUMIDITY HI / LO : Change settings or enable / disable hi or lo temperature / humidity alarm for channel 1 8. °C / °F: Select temperature unit 9. RESET: Reset unit to default settings 10. Battery compartment REMOTE SENSOR (THGR122N) .... Wireless Weather Station with Temperature / Humidity Display and Self-Setting Atomic Clock Model: BAR388HGA 1. Wall mount hole 2. RESET hole 3. CHANNEL switch 4. Battery compartment 1. LCD 2. LED status indicator: Blinks red during data transmission USER MANUAL LCD DISPLAY INTRODUCTION Thank you for selecting this Oregon ScientificTM Wireless Weather Station with Temperature / Humidity Display and Self-Setting Atomic Clock (BAR388HGA). This clock is supplied with a remote sensor (THGR122N) and can support up to 3 sensors in total (additional sensors sold separately). NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. CLOCK OVERVIEW FRONT VIEW Weather Forecast Area: GETTING STARTED .............. BATTERIES SENSOR DATA TRANSMISSION Insert batteries before first use, matching the polarity (+ and -). Press RESET after each battery change. The sensor reception icon in the remote sensor area shows the status. ICON DESCRIPTION Main unit is searching for the sensor(s) A channel has been found and sensor signal is being received 1. Pressure trend 2. Weather forecast 3. Comfort zone 4. Pressure icon 5. Altitude icon 6. Pressure / altitude unit 7. Heat index icon and “- - . -“ (Outdoor temperature Area) The sensor cannot be found. Search for the sensor or check batteries ............ indicates main unit batteries are low. NOTE Do not use rechargeable batteries. We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing. To search for a sensor: Simultaneously, press and hold MEM and CHANNEL for 2 seconds. NOTE If the sensor is still not found, check the batteries, obstructions, and remote unit location. Outdoor Temperature Area: .......................... REMOTE SENSOR CLOCK The sensor collects temperature readings approx. every 40 seconds and sends them to the main unit. The main unit can collect data from up to 3 sensors. To set up the sensor: 1. Remove the screws from the battery door. 2. Insert the batteries, matching the polarity (+ / -). 3. Select a channel. Make sure you use a different channel for each sensor. 4. Place the sensor near the main unit. Press RESET on the sensor. 5. Simultaneously press CHANNEL and MEM on the main unit to initiate signal sending between the sensor and main unit. 6. Close the battery door and secure the screws. 7. Place the sensor in the desired location using the table stand or wall mount. CLOCK RECEPTION This product is designed to synchronize its date and time automatically once it is within range of the WWVB-60 signal from the atomic clock in Fort Collins, Colorado. The clock collects the radio signals whenever it is within 3219 km (2000 miles) of a signal. NOTEInitial reception takes 2-10 minutes for first set up or when RESET is pressed. Once complete, the reception icon will stop blinking. If the signal is weak, it can take up to 24 hours to get a valid signal. 1. Heat index icon 2. Hi / lo temperature alarm 3. Sensor reception icon 4. Sensor battery low 5. Max / min icon 6. Temperature display 7. Ice warning is active 8. Hi / lo humidity alarm 9. Temperature trend 10. Humidity trend 11. Humidity display RECEPTION SIGNAL Clock signal reception indicator: 1. SNOOZE 2. Weather Forecast Area 3. Outdoor Temperature Area 4. Indoor Temperature Area 5. Clock / Alarm Area 6. ALARM: View alarm status; set alarm STRONG SIGNAL WEAK SIGNAL NO SIGNAL Indoor Temperature Area: ............ To enable and force a signal search: Press and hold for 2 seconds. To disable the signal reception: Press and hold for 2 seconds. BACK VIEW ...................... 1. Indoor sensor icon 2. Max / min icon 3. Temperature display 4. Temperature trend 5. Humidity trend 6. Humidity display SET CLOCK If the clock signal reception is enabled and a signal is being received the clock does not need to be manually set. 1. Press and hold MODE for 2 seconds. 2. Press or to change the settings. 3. Press MODE to confirm. 4. The settings order is: US time zone (Pacific (P), Eastern (E), Central (C) and Mountain (M)) offest, hour, minute, year, month, day and language. NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S). Press MODE to choose between the clock with seconds and clock with weekday display modes. Clock / Alarm Area: .............. For best results: • Place the sensor out of direct sunlight and moisture. ...
Dieses Handbuch ist für folgende Modelle:Wettermessung - BAR388HGA (907.62 kb)