Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Brinkmann, modell 842-A100-S

Hersteller: Brinkmann
Dateigröße: 262.8 kb
Dateiname: c2bdf363-485f-eac4-494d-0a77f7f315f7.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Step 3 Remove regulator assembly from under grill inside stove. Replace grill. Make sure burner control knobs are in "OFF" position. Step 4 Attach regulator assembly to stove fitting. HAND TIGHTEN ONLY. Do not cross-thread connections. Step 5 Attach propane cylinder to regulator assembly by turning propane cylinder counter-clockwise. HAND TIGHTEN ONLY. Do not cross-thread connections. CAUTION: Turn cylinder so that it is almost upright, slanted slightly towards you. The cylinder does not sit flat on surface. See diagram below. Step 6 NOTE: Propane canister slants slightly towards front of stove. Follow "Gas Leak Testing" instructions on page 4 of this manual. 3 Cooking Grill Notched Support ArmRegulator Assembly Burner Control Knobs WARNING: Always snap down legs to form a "V" with the stove base to prevent the stove from becoming unstable while in use. Attach Detach Counter-Clockwise Clockwise 842-A100-S_CmpStove.qxd 2/10/06 11:20 AM Page 5 GAS LEAK TESTING WARNING • • • • • Gas leak testing must be performed outdoors in a well ventilated area every time cylinder is connected to stove. Always keep unit away from open flames, sparks or lit cigarettes. Never use a flame to check for gas leaks. The control knobs are used when lighting the burners and to adjust the flame. Never use a unit that has a gas leak. Contact The Brinkmann Corporation’s Customer Service Department for replacement parts or repairs at 800-527-0717. Regulator Watch for Bubbles Regulator Assembly Stove Fitting Step 1 Assemble stove per "Assembly Instructions" on page 3 of this manual. Make sure burner control knobs are in "OFF" position. Step 2 Prepare a soapy water solution (one part dishwashing liquid to three parts water) to test for gas leaks in the connections. Apply a generous amount of the soapy mixture to the regulator assembly at the regulator and stove fitting (located on the right side of stove). Step 3 With the burner control knobs in the "OFF" position, check for bubbles where propane canister attaches to regulator assembly and at stove fitting. If soapy mixture starts bubbling, gas is leaking through the connections. Disconnect the propane canister. Retighten the connection that is leaking gas. Repeat procedure with soapy mixture until gas no longer leaks. NEVER USE A FLAME TO CHECK FOR GAS LEAKS. Step 4 Once all gas leaks have been sealed, WAIT AT LEAST 5 MINUTES FOR GAS FUMES TO DISSIPATE BEFORE LIGHTING THE BURNERS. Carefully follow "Operating Instructions" to light the burner and properly operate this unit. 4 842-A100-S_CmpStove.qxd 2/10/06 11:20 AM Page 6 OPERATING INSTRUCTIONS READ ALL SAFETY WARNINGS AND INSTRUCTIONS CAREFULLY. • DO NOT allow gasoline or other flammable vapors or liquids to come in contact with stove while lighting or at any time during use of stove. WARNING Step 1 Make sure "Gas Leak Testing" from page 4 was completed and the burner control knobs are in the "OFF" position and stove is on a flat surface away from combustible material. Step 2 Decide which burner to light first. Using a long match, hold the flame beside burner. Turn the burner control knob SLOWLY counter-clockwise until the burner lights. WARNING: If the burner does not light within 5 seconds, turn the burner control knobs "OFF" immediately. Wait at least 5 minutes until gas fumes have dissipated before attempting to light burner again. Step 3 To light the second burner, reduce the flame on the first lit burner and repeat Step 2 to the other burner. WARNING: If second burner does not light within 5 seconds, turn the burner control knobs "OFF" immediately. Wait at least 5 minutes until gas fumes have dissipated before attempting to light burner again. Step 4 Adjust burner flame as necessary by using burner control knob. Turn stove "OFF" using burner control knobs when stove is not in use. Step 5 Allow stove to cool completely, then follow instructions in the "After-Use Safety" and "Proper Care & Maintenance" sections of this manual. Minimum clearance to combustibles 36 inches from top and side of stove burners 36" 36" Perimeter of base of stove ON / Larger Flame NOTE: Observe flame height and color when lit. Flame should have a blue center and yellow tip. Burner OFF / Smaller Flame Yellow Blue 5 842-A100-S_CmpStove.qxd 2/10/06 11:20 AM Page 7 AFTER-USE SAFETY • Always allow the stove to cool completely before handling. • Always disconnect the propane cylinder from stove when not in use - a safety cap should be placed on the propane cylinder. • Never store propane cylinder in an enclosed area (house, garage, etc.). Store outdoors in a well ventilated, shaded area away from any heat source or open flame. • Fold wind guards and lid back into their closed position. Unfold legs to lock lid down. PROPER CARE & MAINTENANCE • Wash cooking grill with hot, soapy water, rinse well and dry before storing. Wipe remaining exposed parts of stove with damp cloth. Do not use abrasive materials. • To protect your stove, the unit must be kept clean and cove...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien