Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell SVYD18PRA

Hersteller: Desa
Dateigröße: 711.11 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 13). 5. Fasten back panel to stove with four (4) M6 x 1bolts and washers. 6. Place freestanding stove in desired position in room. Be sure to maintain clearances to combustibles as outlined on page 8. CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot. One-Piece Log Set Burner Middle Section at Bottom of Log Set Heater Base "U" Shaped Cutout in Chassis Figure 12 - Installing One-Piece Stove Log Set Burner Porting Areas (double slotted rectangular openings) One-Piece Log Set Safety Pilot Location Figure 13 - Top View of One-Piece Log Set on Gas Log Heater CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION: Never connect propane/LP heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. 113084-01C INSTALLATION Continued WARNING: Never connect natural gas heater to private (nonutility) gas wells. This gas is commonly known as wellhead gas. Installation Items Needed Before installing heater, make sure you have the items listed below. • external regulator - propane/LP only (supplied by installer) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge connection * • sediment trap • tee joint • pipe wrench * A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 27. The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 14. Make sure gas log heater is secured to the stove cavity assembly. For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 15. Pointing the vent down protects it from freezing rain or sleet. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur. Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 16 on page 13). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliances. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap in supply line as shown in Figure 16, page 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly. Side View Back Stove Back View Panel Gas Inlet Connection Access Stove Unit Front Gas Log Heater Figure 14 - Gas Regulator Location and Gas Line Access Into Stove Cabinet Vent Pointing Down Supply Tank External Regulator Propane/LP Figure 15 - External Regulator With Vent Pointing Down 113084-01C INSTALLATION Continued CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings. PROPANE/LP From External Regulator CSA Design-Certified (11" W.C. to 14" Equipment Shutoff Valve W.C. Pressure) With...

Dieses Handbuch ist für folgende Modelle:
Standbacköfen - SVYD18NRA (711.11 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien