Anleitung Hubbell, modell Fire Pump Controller LX-1500

Hersteller: Hubbell
Dateigröße: 108.18 kb
Dateiname: 21a9ec94-e30c-4e16-a3ca-8df6eaab854b.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Madison, OH 44057 Telephone (440) 428-1161 FAX (440) 428-7635 HUBBELL Instruction Manual Fire Pump Controller Model LX-1500 Limited Service Electric Publication No. 197 April, 2000 Limited Service Fire Pump Controller Table of Contents I Introduction..................................................................................................................................3 II Specifications and Certifications ................................................................................................3 Specifications ................................................................................................................................3 Certifications .................................................................................................................................4 III Receiving, Handling, and Storage.............................................................................................4 IV Installation .................................................................................................................................4 V Sequence of Operation ................................................................................................................5 VI Start Up Procedure....................................................................................................................7 VII Maintenance .............................................................................................................................9 Preventive Maintenance.................................................................................................................9 Troubleshooting.............................................................................................................................9 Coil and Contact Replacement.....................................................................................................10 VIII Limited Service Fire Pump Controller Parts.......................................................................11 Attachments Typical Controller Schematic Typical Field Connection Diagram Notes Refer to job drawings for options. For combination Automatic Transfer Switch/Fire Pump Controller applications, refer to Publication No. 186 for the LX-250 Transfer Switch or Publication No. 195 for the LX-350 Transfer Switch, for details. Page 2 of 12 Limited Service Fire Pump Controller I Introduction The Hubbell Limited Service Fire Pump Controller provides automatic and manual control of small electric motor driven fire pumps and booster pumps of 30 horsepower or less. All Controller components are inside the cabinet with indicating lights and switch handles located next to the door. A pressure switch initiates automatic starting of the pump motor. The Controller monitors the power phases and voltage. The CIRCUIT BREAKER DISCONNECTING MEANS handle has a door interlock feature to prevent opening the door when the switch is closed. The Controller also has an EMERGENCY MANUAL CONTROL handle to start the fire pump manually. CIRCUIT BREAKER EMERGENCY MANUAL DISCONNECTING CONTROL MEANS Incoming Control Panel Surge Suppressor L1 PLM Pressure To Phase Fire Pump Motor M1 T1 Line Switch Control Transformer Figure I-1 Block diagram of LX-1500 showing one phase II Specifications and Certifications Specifications Voltage 208, 240, 380, 480C Phase Loss/Reversal Module A-B-C phase rotation 200 Series 208–240 VAC, 60 Hz, 3 phase 300 Series 380–415 VAC, 50 Hz, 3 phase 400 Series 440–480 VAC, 60 Hz, 3 phase Maximum Voltage 10% of highest nominal voltage Maximum Frequency Shift 0.1 Hz Phase Loss 18% of low voltage in one phase Page 3 of 12 Limited Service Fire Pump Controller Undervoltage Trip 15% below set point Time Delays Pick-up, 1.5 s, fixed Drop-out, 1.5 s, fixed Output Relays 10 A, 120 VAC 5 A, 240 VAC Indication green LED, on for A-B-C phase rotation Surge Suppressor 650 V rating Temperature Operating: -4° F to 104° F (-20° C to 40° C) Storage: -4° F to 182° F (-20° C to 85° C) Certifications The Hubbell Limited Service Electric Fire Pump Controller is built to NFPA 20 requirements. The Controller is listed by: Underwriters Laboratory Factory Mutual Underwriters Laboratory Canada New York City Canadian Standards Association III Receiving, Handling, and Storage 1. Immediately upon receipt, carefully unpack and inspect the Controller for damage that may have occurred in shipment. If damage or rough handling is evident, file a damage claim with the transportation carrier. 2. If the Controller must be stored, cover it and place in a clean, dry location. Avoid unheated locations where condensation can result in damage to the insulation or corrosion of metal parts. IV Installation 1. Consult the motor nameplate to determine voltage, current, and horsepower rating and compare with the Controller nameplate for matching data. 2. Release the door interlock by moving the CIRCUIT BREAKER DISCONNECTING MEANS to the OFF position. 3. Inspect the contro...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien