Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Encore electronic, modell (66-501-1)

Hersteller: Encore electronic
Dateigröße: 2.62 mb
Dateiname: c7e9d5ce-8bb1-4ce6-ac02-83cbf3a6e0dd.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


0 11/04 Copyright © 2004 Delta Machinery INSTRUCTION MANUAL To learn more about DELTA MACHINERY visit our website at: ESPANOL: PAGINA 25FRANCAIS: PAGE 49 For Parts, Service, Warranty or other Assistance, please call 1-866-422-4286. SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known (to the State of California) to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are: • lead from lead-based paints • crystalline silica from bricks and cement and other masonry products • arsenic and chromium from chemically-treated lumber Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using such tools. When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury. A08591 2- ENG IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts within the motor and pressure switch to spark. Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors. If electrical sparks from compressor If spraying flammable materials, locate come into contact with flammable compressor at least 20 feet away from vapors, they may ignite, causing fire or spray area. An additional length of hose explosion. may be required. Store flammable materials in a secure location away from compressor. Restricting any of the compressor Never place objects against or on top ventilation openings will cause serious of compressor. Operate compressor in overheating and could cause fire. an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings. Operate compressor in a clean, dry well ventilated area. Do not operate unit indoors or in any confined area. Unattended operation of this product Always remain in attendance with the could result in personal injury or product when it is operating. property damage. To reduce the risk Always disconnect electrical power by of fire, do not allow the compressor to moving pressure switch lever to the off operate unattended. position and drain tank daily or after each use. 3- ENG A08591 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Failure to properly drain condensed Drain tank daily or after each use. water from tank, causing rust and If tank develops a leak, replace it thinning of the steel tank. immediately with a new tank or replace the entire compressor. Modifications or attempted repairs to the tank. Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure. Never drill into, weld, or make any modifications to the tank or its attachments. Excessive vibration can weaken the The tank is designed to withstand specific air tank and cause rupture or operating pressures. Never make explosion adjustments or parts substitutions to alter the factory set operating pressures. ATTACHMENTS & ACCESSORIES: For essential control of air pressure, Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires, and other inflatables can cause them to explode or fly apart, and could result in serious injury. you must install a pressure regulator and pressure gauge to the air outlet (if not equipped) of your compressor. Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use c...

Dieses Handbuch ist für folgende Modelle:
Pumps - (66-501-1) (2.62 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien