Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Campbell Hausfeld, modell FP2052

Hersteller: Campbell Hausfeld
Dateigröße: 1.25 mb
Dateiname: 0db23ba4-d89f-1a04-918a-6fdb19c037d6.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


HOSE STORAGE 1. Attach one of the threaded ends of recoil hose to air outlet on front of compressor. 2. Route recoil hose to side of tank where hose strap is located. 3. Loosen lower end of hose strap. 4. Slide as much of recoil as possible onto hose strap. 5. Reattach hose strap to compressor. Operation Definition of Terms Regulator - The regulator controls the amount of air pressure released at the hose outlet. ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum. Handle - Designed to move the compressor. Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion. Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture Gauge of Cord 18 18 16 14 14 12 12 10 10 Extension cords for 120V/2.5 Amp Unit Length of Cord (ft) 25 50 100 150 200 250 300 400 500 Figure 2 - Unit Identification Tank gauge Outlet gauge Safety valve On/off switch Regulator Portable Air Compr essor Operation (Continued) from tank by opening the drain valve located underneath the tank. LUBRICATION This is an oilless product and DOES NOT require lubrication to operate. BEFORE FIRST START-UP BREAK-IN PROCEDURE (Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.) 1. Turn regulator knob fully clockwise (to the right) to open air flow. 2. Turn on/off switch to OFF position. 3. Plug in power cord. 4. Turn on/off switch to ON position and run compressor for 5 minutes. 5. Turn on/off switch to OFF position. 6. Unplug power cord. The compressor is now ready for use. BEFORE EACH START-UP OPERATING PROCEDURE 1. Turn regulator knob fully counterclockwise (to the left) to close air flow. 2. Connect air hose to outlet of regulator. 3. Turn on/off switch to OFF position. 4. Plug in power cord. 5. Turn on/off switch to ON position and let compressor run until it reaches automatic shutoff pressure. 6. Attach tire chuck or tool to end of hose. 7. Turn regulator knob clockwise (to the right) to desired pressure of tool being used. On/Off cycling of compressor In the ON position, the compressor pumps air into the tank. When a shutoff (preset “cut-out”) pressure is reached, the compressor automatically shuts off. MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material. IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture. If the compressor is left in the ON position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically. In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting power cord from electrical outlet. ASME SAFETY VALVE Do not remove or ! WARNING attempt to adjust the safety valve! Check the safety valve by performing the following steps: 1. Plug the compressor in and run until shut off pressure is reached (see Operating Procedure). 2. Wearing safety glasses, pull the ring on the safety valve to release pressure from compressor tank. Use your other hand to deflect fast-moving air from being directed toward your face. See Figure 3. Figure 3 4 3. The safety valve should automatically close at approximately 40-50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced. REGULATOR KNOB 1. This knob controls air pressure to an air operated tool or tire chuck. 2. Turn knob clockwise to increase air pressure. 3. To lower air pressure turn knob counterclockwise. 4. Turn fully counterclockwise to shut off flow of air completely. Maintenance ! WARNING Disconnect power source then release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Check compressor often for any visible problems and follow maintenance procedures each time compressor is used. Safety valve must ! WARNING be replaced if it cannot be actuated or it leaks air after ring is released. 1. Turn compressor off and release pressure from system. (To release pressure from ...

Dieses Handbuch ist für folgende Modelle:
Pumps - FP2051 (1.25 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien