Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.6 ( )

Anleitung Henny Penny, modell BCM-110

Hersteller: Henny Penny
Dateigröße: 2.52 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Find the appropriate wires to the PC board and remove the wires from the board. 6. Pull the probe wire through the wiring harness. 7. Install new probe in reverse order. 2-11. FRIGIPROBE 1. Remove the electrical power to the unit. Air Probe Evaporator Probe Frigiprobe To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Using a Phillips head screwdriver, remove the two screws securing the evaporator door, and pull out on the door. 3. Remove the control box from the unit, following steps 2 through 5 in the Control Board Section. 4. Find the appropriate wires to the PC board and remove the wires from the board. 5. Pull the probe wire through the wiring harness. 6. Install new probe in reverse order. 603 2-5 Model BCF-24/65/110, BCM-110 2-12. FUSE AND FUSE HOLDER If the unit has no power, the fuse may be blown. To access the fuse: 1. Remove the electrical power to the unit. To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Remove the two screws securing the front panel and pull down the panel. 3. Unscrew the fuse cap and pull the 10 amp fuse from the holder. To check and replace the fuse holder: 1. Remove the two screws securing the front panel and pull down the panel. 2. Remove the two bolts securing the control box and pull the control box from the unit. (See Control Board Section.) 3. Remove the four screws securing box top and remove the top. 4. Remove the wires from the fuse holder and check for continuity across the terminals. The circuit should show closed. If open, replace fuse holder. 5. Reinstall the control box and front panel, and unit is now ready for use. 2-13. CONDENSATION 1. Remove electrical power to unit and allow evaporator to cool. EVAPORATOR Fuse Holder To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. Also, if evaporator is functional, it will be very hot! Allow evaporator to cool before removing, or burns could result. 2-6 603 Model BCF-24/65/110, BCM-110 2-13. CONDENSATION 2. Bend out the clips securing the rodent cover on the back of EVAPORATOR (Continued) the unit, and pull the cover down. 3. Disconnect the wires to the evaporator. 4. Pull up on the bottom of the evaporator to disengage the evaporator from the bracket. The evaporator is snapped into place. No hardware is securing it. 5. Replace evaporator in reverse order. 2-14. DOOR SEAL 1. Open door and pull out on a corner of the seal until seal clears the retainer. 2. Continue around the door, pulling the seal from the door. 3. Install new seal, starting with the four corners first. 603 2-7 Model BCF-24/65/110, BCM-110 2-15. RUN CAPACITOR 1. Remove the electrical power to the unit. Run Capacitor To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Remove the two screws securing the front panel and pull down the panel. 3. Bend out the clips securing the rodent cover on the back of the unit, and pull the cover down. 4. Using a Phillips head screwdriver, remove the two screws securing the cover of the junction box, and remove the cover. 5. Disconnect the wires from the relay to the capacitor. 6. Remove the capacitor from the unit, from the front. 7. Install new capacitor in reverse order. 2-16. START CAPACITOR AND 1. Remove the electrical power to the unit. START RELAY Start Relay Start Capacitor To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Bend out the clips securing the rodent cover on the back of the unit, and pull the cover down. 3. Using a Phillips head screwdriver, remove the two screws securing the cover of the junction box, and remove the cover. (See section 2-12 above). 4. Disconnect the wires to either the relay or the capacitor, and remove component from the unit. 5. Install new component in reverse order. 2-8 603 2-17. PREVENTIVE MAINTENANCE Procedure Clean all surfaces with a soft cloth, soap and water; do not use abrasives De-ice the evaporator Clean the condenser of dust and obstructions Model BCF-24/65/110, BCM-110 As in all food equipment, the Henny Penny Blast Chiller/Freezer does require care and proper maintenance. The table below provides a summary of scheduled maintenance. Frequency Daily Daily Monthly 603 2-9 Model BCF-24/65/110, BCM-110 Wiring Diagrams BCF/BCM-110 2-10 603 Model BCF-24/65/110, BCM-110 Wiring Diagram BCF-24/65 Refrigeration Diagram BCF-24/65 603 2-11 Model BCF-24/65/110, BCM-110 Refrigeration Diagram BCF/BCM-110-UL Refrigeration Diagram BCF/BCM-110-Int’l. 2-12 603 Model BCF-24/65/110, BCM-110 Electrical/Refrigeration Diagram 603 2-13 Model BCF-24/65/110, BCM-110 Wiring Information of PC Board 1-3 POWER SUPPL...

Dieses Handbuch ist für folgende Modelle:
Pumps - BCF-24/65/110 (2.52 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien