Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Emerson, modell SCROLL SZV44

Hersteller: Emerson
Dateigröße: 3.49 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Max flow using varibable speed drive, compressors operating at 80 Hz. max speed. 2. Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig 3. Performance data to be used as an estimation guide only and is subject to change without notice 30 2006SSD-75 R4 (10/10) Dual-Compressor Module Technical Support and Service Compressor Module Horsepower Selection Chart Module Model Number: SZO56C1A-EDE-240 Configuration Suction Press (PSIG) Max Flow/HP as a function of discharge pressure at maximum flow rate (Note 1) MCFD) 70 80 90 100 110 120 130 140 150 One Module Package -7.5 MCFD 43 42 HP 19 20 0 MCFD 97 96 96 95 94 94 94 93 93 HP 19 21 23 25 26 27 29 30 32 5 MCFD 131 130 130 129 128 128 127 127 126 HP 21 23 24 26 27 29 30 31 33 10 MCFD 165 164 164 163 163 162 161 160 HP 23 24 26 27 28 30 31 33 15 MCFD 198 198 197 197 196 195 HP 25 27 28 30 31 32 20 MCFD 232 232 232 231 230 229 HP 27 28 30 31 31 32 25 MCFD 265 264 264 264 HP 31 31 32 33 Two Module Package -7.5 MCFD 86 84 HP 37 40 0 MCFD 194 193 191 190 188 188 188 187 185 HP 39 43 46 49 52 55 58 60 63 5 MCFD 262 261 259 258 257 256 255 253 252 HP 42 45 49 52 54 57 60 63 66 10 MCFD 329 329 328 327 325 323 321 320 HP 45 48 51 54 57 60 63 65 15 MCFD 396 396 395 394 392 390 HP 51 54 57 59 61 63 20 MCFD 464 465 463 463 460 458 HP 54 56 59 62 63 64 25 MCFD 530 529 528 527 HP 62 63 64 65 NOTES: 1. Max flow using varibable speed drive, compressors operating at 80 Hz. max speed. 2. Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig 3. Performance data to be used as an estimation guide only and is subject to change without notice 31 2006SSD-75 R4 (10/10) Dual-Compressor Module Technical Support and Service Compressor Module Horsepower Selection Chart Module Model Number: SZO44C1A-EDE-244 Configuration Suction Press (PSIG) Max Flow/HP as a function of discharge pressure at maximum flow rate (Note 1) MCFD) 70 80 90 100 110 120 130 140 150 160 170 180 190 One Module Package -7.5 MCFD 33 32 HP 14 15 0 MCFD 75 74 74 73 72 72 72 72 71 71 70 70 70 HP 15 16 18 19 20 21 22 23 24 25 26 27 28 5 MCFD 101 100 100 99 99 98 98 97 97 97 96 96 95 HP 16 17 19 20 21 22 23 24 25 26 27 28 29 10 MCFD 127 126 126 126 125 124 124 123 123 122 122 121 121 HP 17 18 19 20 22 23 24 25 26 27 28 29 30 15 MCFD 152 152 152 152 151 150 150 149 148 148 147 147 HP 19 20 21 23 23 24 25 27 28 29 30 31 20 MCFD 179 179 178 178 177 176 176 175 175 174 173 173 HP 20 21 22 24 24 24 26 28 29 30 31 32 25 MCFD 204 203 203 203 202 202 201 200 199 199 HP 23 24 24 25 27 28 30 31 32 33 Two Module Package -7.5 MCFD 66 64 HP 28 31 0 MCFD 150 148 147 146 145 145 144 144 143 142 141 140 139 HP 29 32 35 37 39 41 44 46 48 50 52 54 57 5 MCFD 201 201 200 199 197 197 196 195 194 193 192 191 191 HP 32 34 37 39 41 43 46 48 50 52 54 56 58 10 MCFD 253 253 252 251 250 249 247 246 246 245 244 243 242 HP 34 37 39 41 43 45 47 49 51 53 55 58 60 15 MCFD 305 305 304 303 301 300 299 298 297 296 295 294 HP 39 41 43 45 46 48 51 53 55 57 60 62 20 MCFD 357 357 356 356 354 353 352 351 349 348 347 345 HP 41 43 45 47 47 49 52 55 57 59 61 64 25 MCFD 407 407 406 405 404 403 402 400 399 397 HP 47 48 49 49 53 57 59 61 63 65 NOTES: 1. Max flow using varibable speed drive, compressors operating at 80 Hz. max speed. 2. Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig 3. Performance data to be used as an estimation guide only and is subject to change without notice Dual-Compressor Module Material Data Safety Sheet 32 2006SSD-75 R4 (10/10) Appendix A - Material Data Safety Sheet The information in this material safety data sheet should be provided to all who use, handle, store, transport or are otherwise exposed to this product. CPI believes the information in this document to be reliable and up to date as of the date of publication, but makes no guarantee that it is. CAUTION This oil is intended for use only in the Copeland Scroll® Compressor used in natural gas applications. Use of any other oil may result in failure and is not covered by warranty. Dispose Waste Oil Properly : • If the oil has not been contaminated, it can be disposed the same as a synthetic motor oil. • If the oil is contaminated, the end user must comply with all applicable regulations for disposal of hazardous materials. A.1 S upplier CPI Engineering Services Inc. 2300 James Savage Rd. Midland, MI 48642 Emergency Number: (989) 496-3780 A.2 P roduct Name and Information Product (Trade name and synonyms) CP-6006 Series Chemical Name Poly-Alpha-Olefin (PAO) Chemical Family Synthetic Hydrocarbon Formula C10nH20n+2 CAS# Proprietary A.3 Components and Hazard Statement This product is non-hazardous. The product contains no known carcinogens. No special warning labels are required under OSHA 29 CFR 1910.1200. FDA Statement. This product complies with FDA 21 CFR 178.3570 regarding lubricants for incidental food contact. A.4 S afe Handling and Storage Handling. Do not take internal...

Dieses Handbuch ist für folgende Modelle:
Pumps - SCROLL SZO56 (3.49 mb)
Pumps - SCROLL SZO56 (3.49 mb)
Pumps - SCROLL SZV32 (3.49 mb)
Pumps - SCROLL SZO44 (3.49 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien