Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Chauvet, modell SNAPSHOT LED PAR 38 TRI-C

Hersteller: Chauvet
Dateigröße: 655.05 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


DMX connector configuration Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other. Important Icon - B&W - 200x201.gif 3-Pin to 5-Pin Conversion Chart If you use a controller with a 5-pin DMX output connector, you will need to use a 5- pin to 3-pin adapter. The chart below details a proper cable conversion: Notes Icon 03 - 200x227.gif 3-PIN TO 5-PIN CONVERSION CHART Conductor 3-Pin Female (Output) 5-Pin Male (Input) Ground/Shield Pin 1 Pin 1 Data ( - ) signal Pin 2 Pin 2 Data ( + ) signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 This drawing provides a general illustration of the DMX input/output panel of a lighting fixture. Universal DMX Controller Continue the link Setting up a DMX Serial Data Link 1. Connect the (male) 3-pin connector side of the DMX cable to the output (female) 3-pin connector of the controller. 2. Connect the end of the cable coming from the controller which will have a (female) 3- pin connector to the input connector of the next fixture consisting of a (male) 3-pin connector. 3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. 4. OPERATING INSTRUCTIONS Configuring the Starting Address Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose the starting addresses for each fixture so that the channels used do not overlap. In addition, you should note the starting address selected for future reference. The LED PAR 38 Tri-B/C fixture uses seven or three DMX channels. If this is your first time using DMX, we recommend reading the “DMX Primer” section in the “Appendix”. Control Panel Functions Access control panel functions using the four buttons located directly underneath the LED display on the included wired remote. BUTTON FUNCTION

Used to scroll through the current operating mode, as well as back out of the current menu option Used to select decreasing advancement in the value Used to select increasing advancement in the value Used to select a value and store it to memory MENU DOWN UP ENTER The Control Panel shows the current state of the unit. It is used to select the operating mode, as well as the sub-features. For a detailed layout of the control panel functions, please see the “menu map” section on the following page. Menu Map MAIN FUNCTION SUB-FUNCTION SELECTION SUB-SELECTION INSTRUCTION P -- P1 7 Color Switching - Select between 2 switching and 2 fading built-in programs P2 7 Color fading P3 3 Color Switching P4 3 Color Fading P5 7 Color sound active Use the Audio Adjustment Knob located on the back of the fixture Select between 2 sound active programs P6 3 Color sound active 3 - CH d001 ~d512 - - Select 3-channel DMX mode (RGB control) 7 - CH d001 ~d512 - - Select 7-channel DMX mode: RGB, macros, run speed, strobe, automatic/sound, dimmer C -- C1 Red - Select between 7 static colors. The display will read C1 ~C7 . The colors that each of these represent are indicated to the left. C2 Green C3 Blue C4 Cyan C5 Magenta C6 Yellow C7 White S -- S001 ~S100 (default range is S050 ) - This is the speed range for the 4 switching and fading built-in programs U -- r --- Red 00 0 ~10 0 Combine red, green, and blue to create a custom, static, color g --- Green B --- Blue DMX Operation This is the operating mode which will allow for control with an external DMX controller. You must set the starting address for this mode. If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer” section in the “Appendix” of this manual. 1. Press until 3 - CH or 7 - CH appears on the LED screen. 2. Press . 3. Using and , select the desired DMX address (d001 ~d512 ). Master/Slave This is the operating mode which will allow 1 fixture to act as the “master” and control all of the other “slave” fixtures. You must set both the master and the slave(s) fixtures to the correct mode for this operation. Master Settings: 1. Connect the fixtures with DMX cables, as shown in the “Fixture Linking” section. 2. Use any one of the standalone modes for the master unit. This includes: P -- , C -- , and U -- Slave Settings: 1. Press until 3 - CH or 7 - CH appears on the LED screen. 2. Press . 3. Using and , set the DMX address to d001 . Notes Icon 03 - 200x227.gif It is not necessary to set the master fixture as the first fixture in the daisy chain. It may be any fixture in the daisy chain. For example: fixture 2, 5, 10 or 12, etc...

Dieses Handbuch ist für folgende Modelle:
Laminiergeräte - SNAPSHOT LED PAR 38 TRI-B (655.05 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien