Anleitung Kenmore, modell 580.75080

Hersteller: Kenmore
Dateigröße: 1.6 mb
Dateiname: dcc40f70-f9b2-4ea4-9c94-88f7e0197e3b.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


A window that faces north is best because it is shaded most of the day. • Do not block air conditioner flow inside with blinds, curtains, or furniture, or outside with shrubs, enclosures, or other buildings. • Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney or into the duct work. • Keep blinds and drapes in other windows closed during the sunniest part of the day. • Clean the air filter as recommended in the MAINTENANCE section of this manual. • Proper insulation and weather stripping in your home will help keep warm air out and cool air in. • External house shading with trees, plants or awnings will help reduce the air conditioner's work load. • Operate heat producing appliances such as ranges, washers, dryers, and dishwashers during the coolest part of the day. -3 OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE. A 250-volt 60 Hz, AC only, 20A fused and properly grounded electrical supply is required. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, serving only this appliance. DO NOT USE AN EXTENSION CORD. 115V~ 230V~ NOTE: The shape may be different according to its model. Use Wall Receptacle Power Supply 3-wire grounding _) tandard 125V, receptacle rated 15A, 125V AC Use 15 AMP. time delay fuse or 15 AMP. Standard 250V, circuit breaker. 3-wire grounding receptacle rated 15A,250V AC Standard 250V, Use 20 AMP. time 3-wire grounding delay fuse or 20 AMP. receptacle rated circuit breaker. 20A, 250V AC RECOMMENDED GROUNDING METHOD For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code (ANSl/NFPA 70) latest edition and all local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician. Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. -4 INSTALLATION REQUIREMENTS Your air conditioner will install intostandard double hung windows with actual clear opening widths of 22 to 36 inches (559mm to 914mm) (FIG. 1). Lower sash must open sufficiently to allow a clear vertical opening of 13 inches (331mm). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser for heat removal. The rear of the unit must be outdoors, not inside a building or garage. 22"to36"qI 1113"m'n.innersilll I _ Window f" ,._".i'l;><-._ SashOffset _,_ si, _,1 t ,_'_ Exterior Interiorw'_l \'4 l," FIG. 1 -. .... . ELECTRICAL SERVICE Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on right side of cabinet). All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use. _!_ [_:TIJ i [*] _1 To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed: • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time. • Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. • Make sure air conditioner does not fall duringinstallation. INSTALLATION HARDWARE ITEM NAME OF PARTS Q"FY A SHORT SCREW 11 B WOOD SCREW 5 C L BRACKET 3 D FOAM STRIP 1 E FOAM SEAL 1 F SIDE CURTAIN 2 G DRAIN PIPE 1 H SUPPORT BRACKET 1 REQUIRED TOOLS: • 3/8-inch open end wrench or...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien