Anleitung Zusammenfassung


MBH 25.4 23.0 20.6 20.1 27.7 25.0 22.5 21.9 30.0 27.1 24.4 23.8 30.4 27.4 24.7 24.0 30.7 27.8 25.0 24.3 TOTAL POWER INPUT kW 2.94 3.31 3.23 3.24 2.98 3.36 3.28 3.29 3.03 3.41 3.33 3.34 3.10 3.49 3.41 3.42 3.17 3.57 3.48 3.49 Sensible Capacity MBH1 Entering Dry Bulb °F 86 15.9 20.0 20.6 20.1 17.7 22.3 22.5 21.9 19.6 24.7 24.4 23.8 19.5 24.9 24.7 24.0 19.5 25.1 25.0 24.3 83 14.4 18.5 20.5 19.9 16.1 20.7 22.5 21.8 17.8 22.9 24.4 23.8 18.2 23.5 24.7 24.0 18.6 24.1 25.0 24.3 80 13.0 17.1 19.6 18.8 14.5 19.1 21.9 21.0 16.1 21.2 24.3 23.3 16.9 22.2 24.6 23.8 17.6 23.2 25.0 24.3 77 11.5 15.6 18.1 17.3 12.9 17.5 20.3 19.5 14.4 19.5 22.5 21.6 15.5 20.9 23.3 22.5 16.7 22.2 24.0 23.4 74 10.1 14.2 16.6 15.9 11.3 15.9 18.7 17.9 12.6 17.7 20.8 19.8 14.2 19.5 21.9 21.1 15.7 21.3 23.1 22.4 71 - 12.7 15.2 14.4 - 14.3 17.1 16.3 - 16.0 19.0 18.1 - 18.2 20.6 19.8 - 20.4 22.1 21.5 68 - 11.3 13.7 13.0 - 12.7 15.5 14.7 - 14.2 17.3 16.3 - 16.8 19.2 18.4 - 19.4 21.2 20.6 115 °F NET CAP. MBH 24.1 20.9 19.0 18.8 26.2 22.8 20.7 20.5 28.3 24.6 22.4 22.1 28.8 25.0 22.7 22.5 29.2 25.4 23.1 22.8 TOTAL POWER INPUT kW 2.70 3.47 3.38 3.40 2.75 3.53 3.44 3.47 2.80 3.60 3.50 3.53 2.86 3.68 3.58 3.61 2.92 3.76 3.66 3.69 Sensible Capacity MBH1 Entering Dry Bulb °F 86 13.9 17.7 19.0 18.8 15.5 19.7 20.7 20.5 17.2 21.8 22.4 22.1 18.1 23.0 22.7 22.5 19.1 24.2 23.1 22.8 83 13.2 17.0 18.8 18.3 14.8 19.0 20.6 20.2 16.4 21.0 22.4 22.1 17.3 22.2 22.7 22.5 18.2 23.3 23.1 22.8 80 12.6 16.3 18.1 17.6 14.1 18.3 20.2 19.7 15.6 20.2 22.4 21.8 16.4 21.3 22.7 22.3 17.3 22.4 23.1 22.8 77 11.9 15.7 17.4 16.9 13.3 17.5 19.5 19.0 14.8 19.4 21.6 21.0 15.6 20.5 21.9 21.5 16.3 21.5 22.2 21.9 74 11.2 15.0 16.7 16.3 12.6 16.8 18.8 18.2 13.9 13.6 20.8 20.2 14.7 19.6 21.0 20.6 15.4 20.6 21.3 21.0 71 - 14.3 16.1 15.6 - 16.1 18.0 17.5 - 17.8 20.0 19.4 - 18.7 20.2 19.7 - 19.7 20.4 20.1 68 - 13.6 15.4 14.9 - 15.3 17.3 16.7 - 17.0 19.2 18.6 - 17.9 19.3 18.9 - 18.8 19.5 19.2 125 °F NET CAP. MBH 22.7 18.9 17.4 17.5 24.7 20.5 18.9 19.0 26.6 22.2 20.4 20.5 27.2 22.6 20.8 20.9 27.7 23.1 21.3 21.4 TOTAL POWER INPUT kW 2.45 3.63 3.53 3.57 2.51 3.71 3.60 3.64 2.56 3.79 3.68 3.72 2.62 3.87 3.76 3.80 2.68 3.96 3.84 3.89 Sensible Capacity MBH1 Entering Dry Bulb °F 86 11.9 15.3 17.4 17.5 13.3 17.2 18.9 19.0 14.7 19.0 20.4 20.5 16.7 21.2 20.8 20.9 18.9 23.4 21.3 21.4 83 12.0 15.5 17.0 16.7 13.5 17.3 18.7 18.6 14.9 19.1 20.4 20.5 16.3 20.8 20.8 20.9 17.8 22.5 21.3 21.4 80 12.2 15.6 16.6 16.4 13.6 17.4 18.6 18.3 15.0 19.2 20.5 20.2 16.0 20.4 20.9 20.8 16.9 21.7 21.3 21.4 77 12.3 15.7 16.7 16.5 13.7 17.5 18.7 18.5 15.1 19.4 20.7 20.4 15.6 20.1 20.5 20.4 16.0 20.8 20.4 20.5 74 12.4 15.8 16.9 16.8 13.8 17.6 18.8 18.6 15.3 19.5 20.8 20.5 15.2 19.7 20.1 20.1 15.1 19.9 19.5 19.6 71 - 15.9 17.0 16.7 - 17.8 18.9 18.7 - 19.6 20.9 20.7 - 19.3 19.8 19.7 - 19.0 18.6 18.7 68 - 16.0 17.1 16.9 - 17.9 19.1 18.8 - 19.8 21.1 20.8 - 19.0 19.4 19.3 - 18.1 17.7 17.8 1. These capacities are net capacities (the indoor fan heat is deducted). ALL SENSIBLE CAPACITY 292443-XTG-D-0508 TABLE 4: DNA036 COOLING CAPACITIES - 3 TON TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 900 CFM 1,050 CFM 1,200 CFM 1,350 CFM 1,500 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F NET CAP. MBH 36.7 34.6 31.9 30.3 37.9 35.7 32.9 31.3 39.1 36.9 34.0 32.3 39.4 37.1 34.2 32.5 39.6 37.4 34.4 32.7 TOTAL POWER INPUT kW 3.57 3.51 3.44 3.41 3.64 3.58 3.51 3.48 3.71 3.65 3.58 3.55 3.80 3.73 3.66 3.63 3.88 3.82 3.74 3.71 Sensible CapacityMBH1Entering DryBulb °F 86 19.8 25.2 29.9 30.3 23.0 28.7 32.0 31.3 26.1 32.1 34.0 32.3 24.8 31.0 34.2 32.5 23.5 29.9 34.4 32.7 83 18.9 24.3 29.0 29.7 21.0 26.7 31.5 31.0 23.1 29.2 34.0 32.3 22.8 29.0 34.2 32.5 22.4 28.8 34.4 32.7 80 18.0 23.4 28.1 28.8 19.1 24.8 29.8 30.5 20.1 26.2 31.5 32.3 20.7 27.0 32.4 32.5 21.3 27.7 33.3 32.7 77 17.1 22.4 27.2 27.9 17.1 22.8 27.8 28.6 17.2 23.2 28.5 29.3 18.7 24.9 30.4 30.5 20.2 26.6 32.2 31.6 74 16.1 21.5 26.2 26.9 15.2 20.9 25.9 26.6 14.2 20.2 25.5 26.3 16.7 22.9 28.3 28.4 19.1 25.5 31.1 30.5 71 -20.6 25.3 26.0 -18.9 23.9 24.7 -17.3 22.6 23.4 -20.9 26.3 26.4 -24.4 30.0 29.4 68 -19.7 24.4 25.1 -17.0 22.0 22.7 -14.3 19.6 20.4 -18.8 24.3 24.4 -23.3 28.9 28.3 95 °F NET CAP. MBH 36.9 34.1 31.4 31.2 37.3 34.5 31.8 31.5 37.7 34.9 32.1 31.9 38.3 35.5 32.6 32.4 39.0 36.1 33.2 32.9 TOTAL POWER INPUT kW 3.77 3.73 3.64 3.61 3.86 3.81 3.72 3.69 3.95 3.90 3.81 3.77 4.03 3.98 3.88 3.85 4.11 4.06 3.96 3.93 Sensible CapacityMBH1Entering DryBulb ° F 86 23.8 29.2 31.4 31.2 25.1 30.8 31.8 31.5 26.5 32.4 32.1 31.9 25.1 31.2 32.6 32.4 23.6 30.0 33.2 32.9 83 21.1 26.5 31.2 31.2 22.2 27.8 31.7 31.5 23.3 29.2 32.1 31.9 22.9 29.0 32.6 32.4 22.5 28.9 33.2 32.9 80 18.4 23.8 28.5 29.3 19.2 24.9 29.8 30.6 20.0 26.0 31.1 31.9 20.7 26.9 32.1 32.4 21.4 27.8 33.2 32.9 77 15.7 21.1 25.9 26.6 16.3 21.9 26.9 27.6 16.8 22.7 27.9 28.7 18.6 24.7 30.0 30.3 20.3 26.7 32.1 31.8 74 13.0 18.5 23.2 23.9 13.3 19.0 23.9 24.7 13.6 19.5 24.7 25.5 16.4 22.5 27.8...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien