Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Bryant, modell 463AAC010BA

Hersteller: Bryant
Dateigröße: 502.17 kb
Dateiname: 463aa_10_12_ba.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This will be required when sills are extra deep See (Fig. 10). Fig 10 V-slot Fig 11 Fig 12 Fig 13 — 9 - Installation Instructions 7. Installation of the cabinet (Model 463AAC010BA and 463AAC012BA) A Place the air conditioner cabinet in the window Align orip hole in the bottom of the cabinet with one hole in the bracket assembly Secure the cabinet to the bracket using a 1/4" screw provided Repeat the same procedure on the opposite side of the cabinet (Fig 14) B Ensure the ”L” shaped mounting channel is positioned in front of the sash The "U” shaped channel on the bottom of the cabinet should be positioned in the track provided on the bracket assembly Pull the window down until it rests just behind the front of the "L" shaped mounting channel See (Fig 15). C Check to make sure that the cabinet is slanted slightly downward on the outside - 10 - Installation Instructions cure shutters A. Carefully slide the air conditioner back into the cabinet. (Please seek assistance for this procedure) , B Reinstall the slide-out-chassis security screws (removed earlier) on both sides of the cabinet {Fig 16) Secure the top of the shutter frames to the window sash with (2) 3/4" screws C Now, secure bottom frames of shutters using one shutter clamp and one 3/4" screw on each side (Fig 16) 9. Reinstalling Front Panel and Air Inlet Grille (Model 463AAC010BA): A Position the front panel on the cabinet starting at the top The front panel lock tabs must be inserted into the retaining slots in the cabinet Repeat this procedure on all sides B Secure the front grille to the cabinet using the Philips screw removed earlier(Fig 17) C Replace the air filter D Position the air inlet grille on the cabinet by gently pressing on it 10. Reinstalling Front Panel and Air Inlet Grille (Model 463AAC012BA) A Position the front panel on the cabinet starting at the top The front panel lock tabs must be inserted into the remaining slots in the cabinet B Secure the front grille to the cabinet using the Philips screw removed earlier 11 Complete the installation A Cut the second foam seal to fit the opening between the top of the inside and outside window See (Fig 18) B Some installations may require additional sealing around the window and air conditioner Check for any air leaks and seal where necessary C In very humid areas, the water removal may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs, you may wish to attach a drain hose (not included) to the drain plug allowing condensations to run off conveniently See (Fig 19) 'ey — 2nd Seal Fig 18 Fig 19 — 11 — Operating Instructions MODE The mode knob controls fan speeds and cooling speed To set desired cooling temperature, simply rotate the mode knob dial to the appropriate setting , AUTO AIR SWING Switch When the Swing switch is turned to the "ON” position, the vertical louvers automatically oscillate sweeping the cold air for comfortable cooling The vertical louvers may be stopped at any position when the Swing switch is turned "OFF" THERMOSTAT The thermostat automatically controls the cooling cycle (compressor) of the air conditioner to maintain room temperature However, the fan motor will continue to operate after the compressor (cooling cycle) is completed LOW FAN will circulate the air at a minimum speed without cooling HIGH FAN will circulate the air at a maximum speed without cooling LOW COOL provides cooling, automatically with minimum air circulation Recommended for nighttime use HIGH COOL provides cooling, automatically with quick cooling or for extremely hot days Once room is cooled, reduce setting to LOW COOL OFF wilt completely shut-off the unit NOTE* After setting the mode, allow 3 minutes before switching to another mode Fresh Air Ventilation is usually kept in the closed position Use only when clearing smoke and/or odors from the room Pull to open Auto Air Swing switch Thermostat knob Mode knob. MODEL 463AAC012BA A CAUTION A When using FAN control, turn slowly allowing unit to adjust When using THERMOSTAT, be sure to allow three minutes before changing temperature Adjusting too quickly may cause an overload resulting in a blown fuse Fresh AIR Vent Lever MODEL 463AAC010BA — 12 Care and Maintenance When servicing the air conditioner, be sure to turn the mode switch to the "OFF" position and disconnect the power cord from the electrical outlet 1 DOT NOT use gasoline, benzine, thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts 2 Never attempt to pour water directly to the front of the unit as this will cause deterioration of the electrical insulation Cleaning the Air Filter Removal of Air Filter If the air filter becomes clogged with dust, air-flow is obstructed and reduces efficiency The air filter should be cleaned once a month More frequent cleaning may be necessary depending on out...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 463AAC012BA (502.17 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien