Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Mermaid, modell Air Conditioner

Hersteller: Mermaid
Dateigröße: 110.91 kb
Dateiname: OWNERS GUIDE 02-17-05.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Introduction to Mermaid SECTION 2 (INSTALLATION and OPERATION) A. Air Conditioner Installation B. Operation SECTION 3 (OPERATION and PROGRAMMING) A. Digital, Programmable Thermostat SECTION 4 (PUMP RELAY BOX) A. Introduction B. Installation SECTION 5 (MAINTENANCE and WINTERIZATION) A. Maintenance B. Winterization SECTION 6 (THEORY of OPERATION and TROUBLE SHOOTING) A. Theory of Operation B. Trouble Shooting FIGURES: 1. Typical Ducting and Venting Scheme 2. Operational Block Diagram 3. Typical Cooling Water Installation 4a. Wiring Diagram "Cool Only" Models 4b. Wiring Diagram "Electric Heat and Cool" Models 4c. Wiring Diagram "Reverse Cycle Heat and Cool" Models 5. Typical Bleed Off Valve Installation SECTION 1 (OVERVIEW) A. Introduction: Congratulations!! You have just purchased one the most dependable Marine Air Conditioners on the market today, a MERMAID. Mermaid supplies pleasure boat owners, custom boat builders, yacht brokers, boat dealers and marinas around the world with their marine air conditioning needs. Mermaid air conditioners are manufactured to the highest of quality standards using only top of the line components and materials assembled by long-term technicians. All of our air conditioners are modularized, self contained, prewired, precharged and mounted on a solid foundation of stainless steel. All of our air conditioning components, such as the evaporator, compressor and condensing coil are manufactured in the USA. All electrical parts are standard refrigeration components and are available across the entire country, and around the world. Any four wire 24Volt digital thermostat will operate any standard Mermaid air conditioner. Don’t forget to see our NEW flush mount digital controller on our website – Our standard electrical control box does not contain any printed circuit boards or solder. All electrical connections are "snap on" color coded wires, making part replacement simple and fast. The electrical box can be unplugged for ease of assembly and service and the entire installation can be accomplished with standard shop tools. Our upgraded controller uses state of the art electonics eliminating any contactor or relay noises. Our warranty is also unsurpassed. For the first 5 years, the Mermaid factory warranty covers all issues with your air unit. After 5 years, any certified air conditioner technician, marine, household or commercial, can service any Mermaid air conditioner model. SECTION 2 (INSTALLATION and OPERATION) A. AIR CONDITIONER INSTALLATION: First, and of foremost importance, the air conditioner and electrical box must be installed in a non-explosive, dry environment. SEE THE FOLLOWING WARNING. WARNING IF THE AIR CONDITIONER OR ELECTRICAL BOX ARE PLACED IN AN EXPLOSIVE ENVIRONMENT OR EXPOSED TO AN EXPLOSIVE ENVIRONMENT OR EXPLOSIVE MATERIALS, EXPLOSION COULD OCCUR RESULTING IN SERIOUS INJURY OR DEATH AND/OR DESTRUCTION OF THE BOAT. THIS COMPONENT DOES NOT MEET FEDERAL REQUIREMENTS FOR IGNITION PROTECTION. DO NOT INSTALL IN SPACES CONTAINING GASOLINE ENGINES, TANKS, LPG/CPG CYLINDERS, REGULATORS, VALVES OR FUEL LINE FITTINGS. FAILURE TO COMPLY MAY RESULT IN INJURY OR DEATH. Typical unit mounting spots are under the vee berth, under settee seats, in hanging lockers, in cabinets or in outside dry lazzeretts and sail lockers. The selected spot must accommodate the following eight requirements. Everything must fit in and/or be accessible to the selected spot: (a) The physical size of the unit and electrical box. (b) Water in and out hoses. (c) Electrical power cable for the unit and pump connections. (d) Air ducting and air splitters. (e) Mounting of the return air grill to insure the proper volume of return air. (f) Access to the high pressure switch. (g) Condensation removal. (h) Thermostat installation and wiring. IMPORTANT READ THE ENTIRE INSTALLATION INSTRUCTIONS BEFORE YOU COMMIT TO CUTTING OR DRILLING ANY HOLES. REMEMBER " HOLES ARE FOREVER". MEASURE, MEASURE, THEN MEASURE AGAIN BEFORE PICKING UP ANY TOOL WITH A SHARP EDGE. IMPORTANT LEAVE AMPLE EXCESS OF HOSE, WIRE AND DUCTING WHEN ROUTING INTO THE AIR CONDITIONER MOUNTING COMPARTMENT TO ALLOW FOR FINAL POSITIONING OF THE AIR CONDITIONER AFTER ALL INSTALLATION TASKS ARE COMPLETED. We will now address each of the above eight requirements in detail: 1. Installing the Air Conditioner Unit: AIR CONDITIONER DIMENSIONS UNIT BTU WIDTH LENGTH HEIGHT 5,200 Cool Only 11.5 Inches 15 Inches 11.5 Inches 5,200 Reverse Cycle 12 Inches 18 Inches 11.5 Inches 6,500 11.5 Inches 16 Inches 11.5 Inches 9,000 11.5 Inches 16 Inches 11.5 Inches 12,000 13 Inches 19.75 Inches 13.75 Inches 16,500 13.5 Inches 19.75 Inches 13.75 Inches 24,000 17 Inches 23 Inches 16.75 Inches The air conditioner needs to be mounted in an area where it will physically fit, as well as accommodate a properly sized return air grill and any ducting or splitters (Wyes) which would be attached to the air output collar. In addition, you need to insure there is spa...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - Air Conditioner (110.91 kb)
Splitgeräte - Air Conditioner (110.91 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien