Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Vixen, modell R-326EX

Hersteller: Vixen
Dateigröße: 1.2 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Obtain the offset constant (K): K=AC - (AB+BC) [Adjustments] • Contact your local dealer for adjustment of the off-set constant when the K is not nearly 0. Instrument Prism Prism A B C A B C Instrument Prism 10.9 Beam axis and line of sight Be sure to check that the beam axis and line of sight are aligned when the adjustments on reticle and perpendicularity of line of sight to horizontal axis are made. [Checks] 4 3 2 1 Set the prism at a distance greater than 50m. Accurately sight the center of the prism through the telescope. Turn the power on and press (MEAS) to measure. No adjustment is necessary if beam receiving buzzer sounds immediately and measurement value is displayed in a few seconds. [Adjustments] • If instrument function is not as described in 4 , contact your local dealer. • This check should be done under good weather conditions. [Checks] 3 2 1 3 2 1 10.10 The EDM beam axis The distance measurement (EDM) beam axis is adjusted to be aligned to the sighting axis of the telescope, but it can be changed a little in case of rapid temperature change, shock or aging. Check your instrument by following procedures. Install the instrument on the tripod and level it at the distance of approx. 50m from the wall. Displace the target plate attached to the end of this manual. Place the target plate adjusting its center to the center of telescope cross line and to be about horizontal to the instrument. Turn the power on, and confirm the [TARGET] is set to the reflecting sheet mode (“S” will be indicated at the top of display, left side of the battery remains sign when it is that.) When it is not, press [F2] [TARGET] and set to eflecting sheet mode (Reference p39 - 6.1 Target setting). 4 Press [F1] [MEAS], then the laser spot appears on the target plate. If the “Center” of the laser spot is within the internal circle (10mm) of the target plate at this moment, the adjustment is unnecessary. • The laser spot disappears in approx. 20 seconds after pressing [F1][MEAS]. Press [MEAS] again, if it is necessary. Target Plate approx. 50m 10mm 10mm Internal circle 20mm 20mm Laser spot “center” [Example: Adjustment is necessary] [Example: Adjustment is unnecessary] [Adjustments] At the procedure 4. above, if the “Center” of laser spot is not within the internal circle (10mm) of the target plate, the adjustment is necessary. Please contact your PENTAX dealer. 11. SPECIFICATIONS Reflectorless items are applicable to “NX” models only. R-322NX R-322EX R-323NX R-323EX R-325NX R-325EX R-335NX R-335EX R-315NX R-315EX R-326EX Telescope Image Erect Optical aperture 45mm EDM aperture 45mm Reticle illumination Intensity settings: 10 steps Auto&Power focus Yes No Method Phase differential - Power By main battery - Pointer Visible la ser Magnification 30 x Resolving power 3” Field of view 2.6% (1° 30’) Minimum focus 1.0m Auto-Focus Auto-focus / Power Focus / Manual Manual Distance measurement Laser Class Visible Laser: Class II (2) / Class IIIa (3R) Visible Laser: - long range mode in Reflectorless (“NX” models only) Class II (2) Measurement range (Good condition) Reflectorless 1.5m -Normal range mode: 90m / long range mode 200m ("NX" models only) - Reflector sheet 1.5m - 600m (800m) Mini prism 1.5m - 1100m (1600m) 1P 1.5m - 3400m (4500m) 1.5m - 3000m (4000m) 1.5m - 2000m (2800m) 3P 200m - 4500m (5600m) 200m - 4000m (5000m) 200m - 2800m (3500m) Accuracy Prism ±(2+2ppm x D)mm ±(3+2ppm x D)mmReflector Sheet Reflectorless ±(5+2ppm x D)mm ±(5+3ppm x D)mm - At Auto-Atm Correction Prism, Ref.sheet: ±(2+10ppm x D)mm / Reflectorless: ±(5+10ppm x D)mm (“NX” models only) ±(3+10ppm x D)mm Measuring time Repeat meas. Normal: Prism, Ref.sheet 2.0sec. (1mm) Normal: Prism, Ref.sheet 1.2sec. (1mm) Track: Prism, Ref.sheet 0.4 sec. (1cm) *Quick mode Initial meas. Normal: Reflectorless 2.3sec. (1mm) Normal: Prism, Ref.sheet 2.5sec. (1mm) (“NX” models only) *Quick mode R-322NX R-322EX R-323NX R-323EX R-325NX R-325EX R-335NX R-335EX R-315NX R-315EX R-326EX Angle measurement Measuring method Absolute rotary encoder Detection 2 sides Minimum count 1” (2cc) / 5” (10cc) selectable Accuracy (ISO 17123-3) 2” 3” 5” 6” Compensator Triple axis Dual axis Tangent screw 2 speed 1 speed Sensitivity of vials Plate level (electronic) 30”/1div. Circular level 8’/2mm Plummet Visible Laser, ±0.8mm (instrument height 1.5m) Base Detachable Shifting Fixed Detachable Dust and IP56 Water protection Ambient temperature -20°C ~ +50°C / -4°F ~122°F (Working range) Tripod thread 5/8” x 11 35mm x 2 5/8” x 11 Dimensions/Weight Instrument 177(W) x 343(H) x 177(L)mm Weight (incl. Battery) 5.7 kg 5.5 kg 5.7 kg Carrying case 268(W) x 442(H) x 465(L) mm/3.9kg Battery pack BP02 Power source Ni-MH (Rechargeable)(4300mAh), DC6V Operation time Continuous Approx. 5 hrs (ETH+EDM),12 hrs (ETH) with Approx. 2.2 hrs of charging time Weight Approx. 380g Charger BC03 and AC Adapter AC01 Input voltage AC 100~240V (AC01) Output voltage DC7.5V (BC03) Weight 280g Internal Memory Coordinates data 20000 ...

Dieses Handbuch ist für folgende Modelle:
Optische Geräte - R-315EX(NX) (1.2 mb)
Optische Geräte - R-315EX(NX) (1.2 mb)
Optische Geräte - R-322EX(NX) (1.2 mb)
Optische Geräte - R-323EX(NX) (1.2 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien