Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Samsung, modell AJN020NDEHA/EU

Hersteller: Samsung
Dateigröße: 871.32 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


If the outdoor temperature drops to /32.F or below, the heating capacity can be reduced depending on the temperature condition. If the cooling operation is used at over 32.C/90.F (indoor temperature), it does not cool at its full capacity. • The use of the air conditioner at a relative humidity above the expected one (80%) may cause the formation of condensate and the leakage of water drops on the floor. NOTE Model : RJ... Mode Outdoor temperature Indoor temperature Indoor humidity If out of conditions Cooling -5.C/23.F ~46.C/115.F 16.C/61.F~32.C/90.F 80% or less Condensation may occur on the indoor unit with risk to have either water blow off or drop on the floor. Heating -15.C/5.F~24.C/75.F 27.C/81.F or less - Internal protection triggers and the air conditioner will stop. Dry -5.C/23.F~46.C/115.F 18.C/64.F~32.C/90.F - Condensation may occur on the indoor unit with risk to have either water blow off or drop on the floor. • The standardizedtemperature for heating is 7.C/45.F. If the outdoor temperature drops to 0.C/32.F or below, the heatingcapacity can be reduced depending on the temperature condition. • If the cooling operation is used at over 32.C/90.F(indoor temperature), it does not cool at its full capacity. NOTE Checking before use Maintaining your air conditioner Internal protections via the unit control system . This internal protection operates if an internal fault occurs in the air conditioner. Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating. De-ice cycle (Defrost cycle) The internal fan will be off to against cold air when the heat pump is heating. Anti-Freezing of Indoor Heat Exchanger The compressor will be off if the heat exchanger termp of indoor unit decrease to 0.C or more to protect from ice build up on the heat exchanger. Protect compressor The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started. • If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures. The internal fan is switched off automatically and restarted only after the de-ice cycle is completed. NOTE Tips on using air conditioner Here are some tips that you would follow when using your air conditioner. TOPIC RECOMMENDATION Cooling • If current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness. • Avoid drastically turning down the temperature. Energy is wasted and the room does not cool faster. Heating • Since the air conditioner heats the room by taking heat energy from outdoor air, the heating capacity may decrease when outdoor temperatures are extremely low. If you feel the air conditioner insufficiently heats, using an additional heating appliance in combination with the air conditioner is recommended. Frost & De-ice • When the air conditio...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - AJN016NDEHA/EU (871.32 kb)
Splitgeräte - AJN026NDEHA/EU (871.32 kb)
Splitgeräte - AJN035NDEHA/EU (871.32 kb)
Splitgeräte - AJN052NDEHA/EU (871.32 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien