Anleitung Zusammenfassung


It will take some time to warm the air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on in advance. Frost When you select the Heat mode, frost may form in the outdoor unit due to low temperature and high humidity. If this happens: .The heating operation is stopped. .The air conditioner defrosts automatically for about 7 minutes. After about 7 minutes, the air conditioner starts operating again normally. High indoor and outdoor temperatures If both the indoor and outdoor temperatures are high when you select the Heat mode, the fan and the compressor of the outdoor unit may stop periodically. This is normal; wait until the air conditioner turns on again. Power failure If a power failure occurs when the air conditioner is operating, the air conditioner will turn off. When the power returns, the air conditioner will start up again automatically. Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal operation starts up after 3 minutes for the reason of protection. The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. .....Any damage occurs out of condition specified cannot be covered by product warranty. If the system works continuosly outside of conditions, its performace and reliability will be compromised. MODE OPERATING CONDITIONS IF OUT OF CONDITIONS Indoor temp: 16°C~32°C - A safety device will stop continuously the system functioning; - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor; COOL Indoor humidity: below 80% Outdoor temp: 21°C~43°C HEAT Indoor temp: below 27°C - A safety device will stop continuously the system functioning; Outdoor temp: 0°C~24°C Indoor temp: 16°C~32°C - A safety device will stop continuously the system functioning; - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor; DRY Indoor humidity: below 80% Outdoor temp: 18°C~43°C POWER SUPPLY Single phase rated voltage minimum and maximum limit 220V-240V~50Hz 198V min.-264V max. 08'FORTE_28591A_IB_E(.A).indd 26 2007-12-7 14:47:26 Problem Explanation/Solution The air conditioner does not operate at all. . .Check if the circuit breaker is switched off. .Check if Off Timer is set. The temperature is not adjusted. .Check if you selected the Fan mode. The air conditioner does not operate in the HEAT mode. .Check if the air conditioner is cooling only model. .Check if the remote control is for cooling only model. The cool(warm) air does not come out from the air conditioner. . . mode. . . Remove the cover or obstacle. . .The window or door may be opened. .Check if you turn on the air conditioner just now. It takes about 3 minutes to cool or heat the room. .Check if the drain pipe is too long. The fan speed is not adjusted. .In Dry mode, the fan speed is selected automatically. The...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - AQ09FA (8.38 mb)
Splitgeräte - AQ09FAN (8.38 mb)
Splitgeräte - AQ09FAX (8.38 mb)
Splitgeräte - AQ09FC (8.38 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien