(optional) The length of the pipe can be: ♦ Extended uptolS meters ♦ Shortened as required »■ If you need a pipe longer than 5 meters: ♦ You must extend the assembly cable. ♦ You must add refrigerant to the pipes; otherwise, the indoor unit may freeze. 1 Makesurethatyou havethe requiredtools(pipecutter, reamer,flaringtool and pipe holder.) 2 Ifyou want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remainsat 90°with the side ofthe pipe (seeexamplesof correctlyand incorrectly cut edges below.) №>■ Oblique Rough Burr JL 3 To prevent a gas leak, removeall burrsatthe cutedge ofthe pipe using a reamer. 4 Put a flare nut slightly intothe pipe and modifythe flare. Outer Diameter (D) 6.35 mm 9.52 mm 12.70 mm 15.88 mm Depth (A) 1.3 mm 1.8 mm 2.0 mm 2.2 mm 5 Check ifyou flared the pipe correctly (see examples ofincorrectly flared pipes below.) Inclined Damaged Surface Cracked Uneven Thickness 6 Align the pipesto connectthem easily.Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Outer Diameter 6.35 mm 9.52 mm 12.70 mm 15.88 mm Torque (kgf*cm) 140-170 250-280 380-420 440-480 7 Forfurtherdetailson howto connecttothe outdoor unit and purgethe air, referto page 13. IM_VIVACE_ENG REV.00 Installing the Air condtioner Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose forthe indoor unit, checkifcondensation draining is adequate. When passing the drain hose through the 65-mm hole drilled in the wall, check the following: The hose must NOT slant upwards. Ditch hose must NOT be placed under water. Shield r \ Ü 7//////[tE = = : -"MJinnnnnnJinnF““1 Drain hose P \ Extension drain hose indifferentdirections. Ieast5cmbetweenthe ofthedrainhoseina endofthehoseand hollow, theground. Drain hose installation: 1 Ifnecessary, connectthe 2-meterextension drain hosetothedrain hose. 2 Ifyou usetheextensiondrain hose,insulatetheinsideoftheextensiondrain hose with a shield. 3 Fitthedrainhoseintol of2drainhoseholes,thenfixtheendofthedrain hosetightly with a clamp. ^ Ifyoudon't usetheotherdrain hose hole, blockitwitha rubberstopper. 4 Passthe drain hose underthe refrigerant pipe, keepingthe drain hosetight. 5 Passthe drain hosethrough the hole inthe wall.Checkifit slantsdownwards as seen in the picture. ^ The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 14 for further details. VIVACE_CIS_DB98-27056AJM_E.lndd 10 17:07:20 Installing the Air condtioner Changing Direction of the Drain Hose You can select the direction of the drain hose, depending on where you want to install the indoor unit. 1 Detach the rubber cap with the flyer. 2 Detach the drain hose by pulling it and turning to the left. 3 Insert the drain hose by fixing it into the groove of the drain hose and the outlet of the drain pan. 4 Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove. ^ One of the diagrams has an illustration with the words "Screws hole" that should be changed to "Screw hole." Installing and Connecting the Drain Hose of the Indoor Unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following: 1 Insert the drain plug into the drain hole on the underside of the outdoor unit. ^ There are 3 drain holesonthe underside. You can use any hole for yourconvenience. 2 Connect a drain hose to the drain plug. 3 Ensure that condensation draining is adequate. VIVACE_CIS_DB98-27056AJM_E.lndd 11 17:07:21 Installing the Air condtioner Connecting the Assembly Cable The outdoor unit is powered from the indoor unit through the assembly cable. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15 meters. 1 Extend the assembly cable if necessary. 2 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit. 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals as seen in the picture. >• Each wire is labeled with the corresponding terminal number. 5 Pass the other end of the cable through the 65mm hole in the wall. 6 Close the connector cover, tightening the screw carefully. 7 Close the front grille. 8 Remove the terminal board cover on the side of the outdoor unit. _ # 9 Connect the cables to the terminals as seen in the picture. >■ Each wire is labeled with the corresponding terminal number. 10 Connect the grounding conductor to the grounding terminals. 11 Close the terminal board cover, tightening the screw carefully. 12 Connect the power cable to the indoor unit. * The designs and shape are subject to change according to the model. ^ In ...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - AQ09VBLN (4.77 mb)