Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Mitsubishi Electronics, modell LOSSNAY LGH-25RX4-E

Hersteller: Mitsubishi Electronics
Dateigröße: 1.4 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


For connection of a remote controller (PZ-41SLB-E) If the Lossnay’s operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out the appropriate operation in accordance with the following table. Also, please see the installation and user’s manual for the remote controller (PZ-41SLB-E). Example of System Operation Function Lossnay Power Supply Remote Controller (Optional parts) (PZ-41SLB-E) Run using the remote controller. • If 2 remote controllers are used, the last controller to be used has priority. (Last Command) Lossnay Power Supply External device Remote Controller (Optional parts) (PZ-41SLB-E) Power Supply Operation switch for the external device If an external device is connected the “On/Off” function of this device will also control the Lossnay operation. • If you would like to turn ON the Lossnay alone while the external device is OFF, operate it by the Lossnay remote controller. Lossnay Power Supply External device Power Supply Operation switch for the external device • The fan speed is on “High”. • The ventilation mode is “Ventilation Mode Auto Select”. 2. For connection of a Lossnay remote controller (PZ-52SF-E), Mitsubishi Electric Air-Conditioner Network System (MELANS) or City Multi. This is to be incorporated and used in the Mitsubishi Electric Air- Conditioner Network System. This is interlocked with the City Multi and operated by it. If the Lossnay remote controller (PZ-52SF-E) is used, the Lossnay may be operated independently if connected to City Multi. For details, refer to the operating manual of PZ-52SF-E. Lossnay operation using the Lossnay remote controller (PZ-52SFE) should need the power supply unit. Refer to the system diagram below. Note • If this is to be used with the Lossnay remote controller (PZ52SF- E), refer to the manuals for both the PZ-52SF-E installation and operating manual. • Remote controller PZ-41SLB-E cannot be used with this system. ¦ System diagram Basic system Power supply unit Power supply MELANS PAC-SC34KUA Lossnay unit LGH-**RX4-E Lossnay remote controller (PZ-52SF-E) M-NET transmission line Interlocked to the City Multi indoor unit City Multi indoor unit Power supply A/C’s remote controller Lossnay unit LGH-**RX4-E M-NET transmission line ¦ LOSSNAY VENTILATE setting Both fresh air supply and return air pass through the Lossnay core(s). Resulting in full heat exchange. Lossnay ventilate setting is used for cooling in the summer and heating in the winter period. Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4 Damper Damper Exhaust air Return air Exhaust air Return air Fresh air Supply air Fresh air Supply air Return air Fresh air Exhaust air Supply air Lossnay core Lossnay core ¦ BY-PASS VENTILATE setting The fresh air passes through the Lossnay core(s) and the return room air is exhausted direct. Lossnay bypass ventilate is normally operated duri...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - LOSSNAY LGH-100RX4-E (1.4 mb)
Splitgeräte - LOSSNAY LGH-150RX4-E (1.4 mb)
Splitgeräte - LOSSNAY LGH-15RX4-E (1.4 mb)
Splitgeräte - LOSSNAY LGH-200RX4-E (1.4 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien