Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Fujitsu, modell AUU36RC

Hersteller: Fujitsu
Dateigröße: 708.5 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


En-15 SYSTEM OPERATION Outdoor One remote controller can control up to 16 air conditioners. unit All the air conditioners can be operated with the same setting. Remote controller Unit No.1 Unit No.2 Unit No.16 Indoor unit To Use the ZONE CONTROL When the ZONE control button is pressed while multiple air conditioners are being centralized controlled, only the preset air conditioners stop. Press the ZONE control button. Preset units will stop. The ZONE lamp (green) will light. To Stop the ZONE CONTROL Press the ZONE control button one more time. Those units that were stopped will start again. The ZONE lamp will go out. TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE °F NON STOP AM CLOCK AUTO En-16 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec- WARNING! trical breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off. Before requesting service, perform the following checks: Symptom Problem See Page NORMAL FUNCTION Doesn’t operate immediately: . If the unit is stopped and then immediately started again, the compressor will not operate for about 3 minutes, in order to prevent fuse blowouts. . Whenever the electrical breaker is turned off then on again, the protection circuit will operate for about 3 minutes, preventing unit operation during that period. — Noise is heard: . During operation and immediately after stopping the unit, the sound of water flowing in the air conditioner’s piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing). . During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the panel due to temperature changes. — *. During Heating operation, a sizzling sound may be heard occasional. This sound is produced by the Automatic Defrosting operation. 15 Smells: . Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner. — Mist or steam are emitted: . During Cooling, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting. — *. During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the unit. This is due to Automatic Defrosting operation. 15 Air flow is weak or stops: *. When Heating operation is started, fan speed is temporarily very low, to allow internal parts to wa...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - AOU18RC (708.5 kb)
Splitgeräte - AUU36RC (708.5 kb)
Splitgeräte - AUU42RC (708.5 kb)
Splitgeräte - AOU18RC (708.5 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien