Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Panasonic, modell CWC83GU

Hersteller: Panasonic
Dateigröße: 3.09 mb
Dateiname: CWXC63HU.PDF
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Attach the upper guide onto the top of the cabinet with 3 type A screws. 6. Insert the frame guides into the bottom of the cabinet. 7. Insert the Frame Curtain into the upper guide and frame guides . 8. Fasten the curtains to the unit with 4 Type A screws. 12 Features and Installation Suggested Tool Requirements Installation Kit Contents SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL NO. NAME OF PARTS Q'TY 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 5 SCREW(TYPE A) (10mm(2/5")) 16 6 SCREW(TYPE B) 3 7 SCREW(TYPE C) 5 8 FOAM-STRIP 1 9 UPPER GUIDE 1 10 FOAM-PE (466mm x 10mm x 2mm) 1 11 FRAME GUIDE 2 12 WINDOW LOCKING BRACKET 1 13 FOAM-PE (920mm x 30mm x 2mm) 1 14 DRAIN PIPE 1 D5.1mm(0.2") 16mm(0.63") D4.1mm(0.17") 16mm(0.63") 13 Features and Installation Upper Guide Window Sash Window sill Front Angle Upper guide 9 Frame Curtain 1 Foam-pe 10 Foam-pe 13 Cabinet INDOOR OUTDOOR INDOOR OUTDOOR Sash track Front Angle Cabinet About 12.7mm (1/2") About 12.7mm (1/2") Sill Support 2 Bolt 3 Nut 4 Frame Guide 11 Screw (Type B) 6 Screw (Type B) 6 Sill support 2 Sill support 2 Screw (Type A) 5 1. Open the window. Mark a line on center of the window sill (or desired air conditioner location). Carefully place the cabinet on the window sill and align the center mark on the bottom front with the center line marked in the window sill. 2. Pull the bottom window sash down behind the upper guide until it meets. NOTE: • Do not pull the window sash down so tightly that the movement of Frame Curtain is restricted. 3. Loosely assemble the sill support using the parts in Fig. 3. 4. Select the position that will place the sill support near the outer most point on sill (See Fig. 4) NOTE: Be careful when you install the cabinet (frame guides are broken easily). 5. Attach the sill support to the cabinet track hole in relation to the selected position using 2 Type A screws in each support (See Fig. 4). 6. The cabinet should be installed with a very slight tilt (about 12.7mm(1/2")) downward toward the outside (See Fig. 5). Adjust the bolt and the nut of sill support for balancing the cabinet. 7. Attach the cabinet to the window sill by driving the screws (Type B) through the front angle into window sill. 8. Pull each Frame curtain fully to each window sash track, and repeat step 2. Cabinet Installation Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Type C 7 Screw (Type A) Screw (Type A) Power cord Foam-Strip 8 Window locking bracket 12 14 Features and Installation 9. Attach each Frame curtain to the window sash using screws (Type C). (See Fig. 6) CAUTION: DO NOT DRILL A HOLE IN THE BOTTOM PAN. The unit is designed to operate with approximately 12.7mm (1/2") of water in bottom pan. 10. Slide the unit into the cabinet. (See Fig. 7) CAUTION: For security purposes, reinstall screws (Type A) at cabinet's sides. 11. Cut the foam-strip to the proper length and insert between the upper window sash and the lower window sash. (See Fig. 8) 12. Attach the window locking bracket with a type C screw. (See Fig. 9) 13. Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (See Fig.10) NOTE: Please refer p.8 for setting ventilation kit. 14. Lift the inlet grille and secure it with a type A screw through the front grille. (See Fig. 11) 15. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Electrical Data Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut or remove the grounding prong from the plug. Power supply cord with 3-prong grounding plug Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use 15 AMP, time delay fuse or circuit breaker. USE OF EXTENSION CORDS Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V. 15 Features and Installation Electrical Safety (Applies to USA only) Features and Installation IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet (Fig. 16) to minimize the hazard of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded. PREFERRED METHOD Ensure proper ground exists before use Fig. 16 DO NOT CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG. A. SITUATIONS WHERE THE APPLIANCE WILL BE DISCONNECTED ONLY OCCASIONALLY: TEMPORARY METHOD Adapter plug Receptacle cover Metal screw Fig. 17 Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien