Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Panasonic, modell CUXC123KP

Hersteller: Panasonic
Dateigröße: 883.52 kb
Dateiname: CUC73K.PDF
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


18-21 • Cleaning the Indoor Unit and Remote Control • Cleaning the Air Filter • Cleaning the Front Panel ■ Removing the front panel ■ Fixing the front panel ■ Cleaning the front panel • Replacing the Air Purifying Filters ■ Removing the air purifying filters ■ Reinstalling the air purifying filters . • Pre-season Inspection • When the Air Conditioner is Not Used for an Extended Period of Time • Recommended Inspection ► TROUBLESHOOTING......... .............................22 - 23 • Normal Operation • Abnormal Operation . -,, ■ • Call the Dealer Immediately ► HELPFUL INFORMATIONS................... .................... 24 V - ► .........2 ... 3-5 ...6-9 10-11 ► ENERGY SAVING AND OPERATION HINTS...............25 FEATURES Thank you for purchasing our National/ Panasonic Room Air Conditioner. V_y ^ Note: Before using your air-conditioner, please read this operating instructions carefuliy and keep it for future reference. • AUTOMATIC OPERATION Selects the optimum mode. (Refer page 12) • SLEEP MODE Prevent the room from getting too hot or too cold while you are sleeping. (Refer page 16) • ECONOMY MODE To reduce electrical power consumption. (Refer page 17) • POWERFUL MODE Reaches the desired room temperature quickly. (Refer page 17) • REMOVABLE FRONT PANEL For quick and easy cleaning (washable). (Refer page 19) • AIR PURIFYING FILTER (WITH DEODORIZING FUNCTION) Reduce dust, smoke and odours in the room. (Refer page 20) • AUTO RESTART CONTROL Automatically restart the unit after power failure. (Refer page 24) 2 ENGLISH SAFETY PRECAUTIONS Before operating, please read the following “Safety Precautions” carefully. To prevent personal injury, injury to others and property damage, the following instructions must be followed. ■ Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follows: A Warning This sign warns of death or serious injury. V_J A Caution This sign warns of damage to property. ■ The instructions to be followed are classified by the following symbols : 0 This symbol (with a white background) denotes an action that is PROHIBITED. V_ These symbols {with a black background) denote actions that are COMPULSORY. Installation Precautions A Warning Do not install, remove and reinstall the unit yourself. Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work. A Caution This room air conditioner must be earthed. o Improper grounding could cause electric shock. Do not install the unit in a place where there may be explosive gas leaks. 0 Gas leaks near the unit could cause fires. Ensure that the drainage piping is connected properly. o Otherwise, water will leak out. 3 Operation Precautions -1 (*\) A Warning I This sign warns of death or serious injury. 0 Do not share outlet. Do not repair by yourself. Do not insert plug to operate the unit. Do not pull out plug to stop the unit. O 0 Plug in properly. Do not operate with wet hands. O 0 Use specified power cord. Do not damage or modify the power cord. If abnormal condition (burnt smell, etc) occurs, switch off and unplug the power supply. Do not insert finger or other objects into the indoor or outdoor units. Switch off the power supply if the unit is not used for a long period. A Caution This sign warns of injury. Do not pull the cord to disconnect the plug. Switch off the unit before cleaning it. 0 Do not wash the unit with water. 0 Do not use for other purpose such as preservation or etc. 0 Do not use any combustible equipment at airflow direction. Ventilate the room regularly (once or twice every 2 hours). Do not sit or place anything on the outdoor unit. 0 Pay attention as to whether the installation rack is damaged due to long period of usage. 5 NAME OF EACH PART Indoor Unit Front Panel Air Intake Vent : Red : Orange : Orange ■ When the front panel is opened 6 ENGLISH • Outdoor Unit CU-C73K CU-C93K CU-C123K Air Intake Vents (Side) ^ (Rear) Piping Connecting cable Drain Hose Air Outlet Vents Ground Terminal (Inside Cover) Air Intake Vents (Side) Connecting cable ®-Drain Hose m—P'P'ng Ground Terminal (Inside Cover) Air Outlet Vents 7 • Remote Control When the remote control cover is opened Fan Speed Selection Button Manual Airflow Direction Selection Button Operation Display Operation Mode Selection Button Clock Button Time-Setting Button Sleep Mode Operation Button Timer Cancellation Button Economy Mode Operation Button Auto Airflow Direction Button OFF-TIMER Button ON-TIMER Button Timer Set Button 8 ENGLISH How to use the remote control Notes Do not throw or drop Do not get it wet Certain type of flourescent lamps may affect signal reception. Consult your dealer. Signal receptor • Signal received sound. One short beep or one long bee...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien