Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Heat Controller, modell DMH36TB-1

Hersteller: Heat Controller
Dateigröße: 2.83 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


As the compressor starts, the fan speed also resumes its previous setting mode. Helpful information Fan speed and cooling capacity. The cooling/heating capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool/heat the room quickly. In case of absence for a long time while power failure, turn off main power to avoid undersired Auto restart. Auto restart This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp(2) will blink 4 times. To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator lamp(1) will blink 4 times. NOTICE ON/OFF button High Speed 22 Room Air Conditioner Maintenance and Service CAUTION: Before performing any maintenance, turn off the main power to the system. Grille, Case, and Remote Control . Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Supply power must be disconnected before cleaning the indoor unit. AIR FILTERS The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary. TRIPLE DEODORIZER filter 1. After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZING filter. 2. Dry in the sunlight for two hours. 3. Re-install the TRIPLE DEODORIZING filter to the original position. . Never use any of the followings: • Water hotter than 40°C(104°F) Could cause deformation and/or discoloration. • Volatile substances Could damage the surfaces of the air conditioner. 1. Lift the front access panel and pull the filter tab slightly forward to remove the filter. 2. Clean the filter with a vacuum cleaner or warm, soapy water. • If dirt is conspicuous, wash with a solution of detergent in lukewarm water. • If hot water (40°C (104°F)or more) is used, it may be deformed. 3. After washing with water, dry well in the shade. 4. Re-install the air filter. NOTICE Gasoline Powder TRIPLE DEODORIZING Filter Air inlet vent Vertical louver Air outlet vent Horizontal louver Air filters (behind front panel) Maintenance and Service Indoor Unit Maintenance and Service When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. 1. Operate the air conditioner on Air circulation mode (Refer to page 19) for 2 to 3 hours. • This will dry out the internal mechanisms. 2. Turn off the circuit breaker, and disconnect the power cable. CAUTION: Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. 3. Remove the batteries from the Remote Controller. Operation Tips 1. Clean the air filter and install it in the indoor unit. (Refer to page 22 for cleaning filters.) 2. Check that the air inlet and outlet of the indoor/outdoor unit are not blocked. When the air conditioner is to be used again. Do not overcool the room. Keep blinds or curtains Keep the room temperature closed. uniform. This is not good for the health Do not let direct sunshine enter Adjust the vertical and and wastes electricity. the room when the air horizontal airflow direction to conditioner is in operation. ensure a uniform temperature in the room. Make sure that the doors Clean the air filter regularly. Ventilate the room and windows are shut tight. occasionally. Avoid opening doors and Blockages in the air filter reduce Since windows are kept closed, windows if possible to keep the the airflow and lower cooling it is a good idea to open them cool air in the room. and dehumidifying effects. and ventilate the room now and Clean at least once every two then. weeks. Owner's Manual 23 Maintenance and Service Troubleshooting Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center. Case Explanation See page The air conditioner does not • Check room temperature setting? 12, 15 operate. • Check if circuit breaker is on? - The room has a peculiar odor. • Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room. - It seems that condensation is leaking from the air conditioner. • Check the drain hose is connected tight or if indoor unit is installed even. - Air conditioner does not operate for about 3 minutes after turning on. • This is the protector of the mechanism. • Wait about 3 minutes and operation will begin. • About 3 minutes delay is applied to protect compressor from frequenty on/off. - Does not cool or heat effectively. • Is the air filter dirty? See air filter cleaning instructions. 22 • Has the temperature been set correctly? 12, 15 • Are the indoor unit's air inlet or outlet vents obstructed? - The air conditioner operation is noisy. • For a noise that sounds like w...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - DMC24DB-1 (2.83 mb)
Splitgeräte - DMC36TB-1 (2.83 mb)
Splitgeräte - DMH24DB-1 (2.83 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien