Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Agilent Technologies, modell FIXTURE U7242A

Hersteller: Agilent Technologies
Dateigröße: 169 kb
Dateiname: U7242-97000.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as "Commercial computer software" as defined in DFAR 252.227-7014 (June 1995), or as a "commercial item" as defined in FAR 2.101(a) or as "Restricted computer software" as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies' standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. 2 Agilent U7242A USB 3.0 Test Fixture User's Guide Contents U7242A USB 3.0 Test Fixture Description 5 Fixture and Accessories 6 Dimension 6 Characteristics, Regulatory, and Safety Information 7 Electrical Characteristics 7 Operating and Non-operating Environmental Characteristics 7 Safety Information 7 3 Agilent U7242AUSB 3.0 Test Fixture User's Guide 4 U7242A USB 3.0 Test Fixture Description The U7242A USB3.0 test fixture is required to perform the measurement with the Agilent U7243A USB3.0 Electrical Compliance Test Application. The fixture helps you to easily access the USB3.0 test signals. The U7242A USB3.0 test fixture is required for the all the Far End (TP1) tests including: • Far End Unit Internal test • Far End SSC Slew Rate test • Far End Template test • Far End Peak-to-Peak Differential Output Voltage test • Far End RMS Random Jitter test • Far End Maximum Deterministic Jitter test • Far End Total Jitter at BER-12 test Figure 1 U7242A USB3.0 Test Fixture Board Agilent Technologies 5 Fixture and Accessories The complete set of USB3.0 test fixture contains the following items: Part Number Description Quantity U7242-66501 USB 3.0 test fixture 1 unit 8121-1880 USB 3.0 Std-A to Std-B cable (4 inches) 1 unit 8121-1924 USB 3.0 Std-A to Std-B cable (3.1 inches) 1 unit 1253-8358 Double Banana Plug With Shorting Bar 1 unit Dimension The dimension of the U7242A test fixture board is as follows: PCB board height = 2.00 inches PCB board width = 7.75 inches PCB board thickness = 0.063 inches 6 Characteristics, Regulatory, and Safety Information Electrical Characteristics The following electrical characteristics are the specification of the U7242A USB3.0 test fixture: Description Specification Trace Impedance 100 ohm + 10% Mated Connector 90 ohm + 10% Cable 90 ohm + 10% Operating and Non-operating Environmental Characteristics The following are the environmental characteristics of the U7242A USB3.0 test fixture: Description Minimum Requirement Ambient temperature Operating = 0°C to 40°C Non-operating = - 51°C to 71°C Humidity Operating = 95% RH at 40°C for 24 hours Altitude Operating = 4,570m (15,000 ft) Non-operating = 15,244m (50,000 ft) Indoor use This fixture is rated for indoor use only Random vibration HP/Agilent class B1 and MIL-PRF-2880 OF Class 3 random Mechanical shock HP/Agilent class B1 and MIL-PRF-2880 OF (operating 30g, 1/2 sine, 11-ms duration, 3 shocks/axis along major axis. Total of 18 shocks) Safety Information The U7237A 10GBASE-T transmitter test fixture herewith complies with the essential requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly. The product was tested in a typical configuration with HP/Agilent test systems The following are the safety regulatory information of the U7237A 10GBASE- T transmitter test fixture: 7 Minimum Requirement: IEC 61010-1: Second edition 2001-2 EN 61010-1:2001 UL3111-1 or UL 6101B-1:2003 (must be an Agilent ID) Canada: CSA-C22.2 No. 1010.1:1992...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien