Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Harman Stove Company, modell 828i

Hersteller: Harman Stove Company
Dateigröße: 1.63 mb
Dateiname: 284ccc72-cc45-48c5-8caf-a2c52c407570.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLYINSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT. CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE COMPANY. SAVE THESE INSTRUCTIONS. The Harman Clarity 828i Gas Fireplace Insert Installation & Operating Manual “Ce manuel est disponible en Francais sur demande” R5 2 Manufactured by: Harman Stove Co. 352 Mountain House Road Halifax, PA 17032 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ADVETISSEMENT: Quinconque ne respect pas a la lettre les instructions dans le present manuel risque de declencher un incendie ou une explosion entraiant des dommages materials, des lesions corporelles ou la perte de vies humaines. Installation ou modification, consulter le manuel des usagers fourn avec ce generateur d'air chaud. Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil. 3 INTRODUCTION..................................................... 4 INSTALLATION ...................................................... 5 Clearances ........................................................... 5 Venting ................................................................ 6 Test for Flue Spillage .......................................... 6 ASSEMBLY................................................................ 7 Connecting to a Gas Supply ............................. 8 Connecting the Cordset and Thermostat ........ 9 Installing into a Fireplace ................................ 10 Air Shutter Adjustment ................................... 11 Monitoring the Gas Flame ............................... 11 OPERATION........................................................... 11 How to Light the Fire....................................... 11 How to Turn Off the Fire ................................ 12 MAINTENANCE.................................................... 12 Removing the Glass .......................................... 12 Replacing the Gasket ....................................... 12 Inspecting the Venting..................................... 13 Cleaning the Glass............................................ 13 Cleaning the Log Set and Firebox .................. 13 Convection Blower Service Access..................13 Reference Pictures .......................................... 14 APPENDIX A: FUEL CONVERSION.................. 15 APPENDIX B: ALTITUDE DE-RATING............. 16 APPENDIX C: CHANGING ORIFICES............... 17 APPENDIX D: WIRING DIAGRAM.................... 18 PARTS LIST & DRAWING......................... 19-20-21 SPECIFICATIONS.................................................. 22 TABLE OF CONTENTS 4 Introduction The Harman Clarity 828I Vented Gas Fireplace Insert is a listed gas-fired vented room heater tested by Intertek Testing Services/Warnock Hersey to ANSI standard Z21.88-2002, CSA2.33- M02, and CAN/CGA-2.17-M91. The installation of the Clarity Fireplace Insert must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 — latest edition (NFPA 54) and CAN 1 B1- 149.1 and .2 Gas Appliance Installation Code. Installer l'appareil selon les codes ou reglements locaux, ou, en l'absence de tels reglements, selon les Codes d'installation CAN/CGA-B149. The Clarity Fireplace Insert is not for use in mobile homes. CAUTION: This appliance must be vented to the outside. INSTALLATION AND REPAIR OF THE CLARITY FIREPLACE INSERT SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS, AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN. ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. S'ASSURER QUE LE BRULEUR ET LE COMPARTIMENT DES COMMANDES SONT PROPRES. VOIR LES INSTRUCTIONS D'INSTALLATION ET D'UTILISATION QUI ACCOMPAGNENT L'APPAREIL. When operating your Harman Clarity Fireplace Insert, respect basic safety standards. Read these instructions carefully before you attempt to operate the heater. Failure to do so m...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien