Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Regency, modell FREESTANDING WOODSTOVES F3100L

Hersteller: Regency
Dateigröße: 2.06 mb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


Generally you can get closer clearances with the airmate than with the rear heat deflector. Airmate OR Rear Heat Deflector Convection heat with Airmate vs. Radiant Heat with Rear Heat Deflector. The airmate pushes heat forward and into the room, the rear heat deflector deflects the heat upward. See installation instructions on pages 11 and 12. (all units) Pedestal OR Legs There are no performance differences with either the pedestal or legs. It is primarily a personal preference. Legs can be either painted steel, painted cast, or gold plated cast. Leg installation requires the bottom shield. See installation instructions on page 13. OPTIONS: These can be installed at time of installation or added later: Modular Option Things to consider when choosing options Blower/Fan Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove is installed. Installation instructions on page 18. Ash Drawer Kit Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner. Installation instructions on page 17. Regency Freestanding Woodstove INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Residential Installation “C” Vent (Single Wall) Unit From Unit A B From Corner C D From Flue Center-line E F Small F1100S with Airmate 13" 11" 8" 25" 17.5" 20" with Rear Deflector 15" 10.5" 11" 27" 17" 23" Medium F2100M with Airmate 14" 10" 6" 26" 16.5" 17.5" with Rear Deflector 17" 11" 9" 29" 17.5" 21" Medium S2100M Step Stove 14" 10" 6" 26" 16.5" 17.5" Large F3100L with Airmate 18" 12" 8.5" 32" 18.5" 22" with Rear Deflector 20" 14" 10.5" 34" 20.5" 24" Large S3100L Step Stove 18" 12" 8.5" 32" 18.5" 22" Residential Close Clearance (To be installed with required pipe components) When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level. Unit From Unit A B From Corner C D From Flue Center-line E F Small F1100S with Airmate 9" 5" 3" 21" 11.5" 15" with Rear Deflector 13.5" 5" 5" 25.5" 11.5" 17" Medium F2100M with Airmate 10" 4.5" 7.5" 22.5" 11.5" 20" with Rear Deflector 14" 7" 8.5" 26.5" 14" 21" Medium S2100M Step Stove 10" 4.5" 7.5" 22.5" 11.5" 20" Large F3100L with Airmate 16" 9.5" 8.5" 30" 16" 22" with Rear Deflector 20" 12" 8.5" 34" 18.5" 22" Large S3100L Step Stove 16" 9.5" 8.5" 30" 16" 22" Mobile Home Close Clearance (To be installed with required pipe components) "C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.) Unit From Unit A B From Corner C D From Flue Center-line E F Small F1100S with Airmate 11" 6" 6" 23" 12.5" 18" with Rear Deflector 13" 5" 9" 25" 11.5" 21" Medium F2100M with Airmate 16" 8.5" 7.5" 28.5" 15.5" 20" with Rear Deflector 18" 8.5" 8.5" 30.5" 15.5" 21" Medium S2100M Step Stove 16" 8.5" 7.5" 28.5" 15.5" 20" Large F3100L with Airmate 18" 9.5" 10" 32" 16" 23.5" with Rear Deflector 20" 12" 10" 34" 18.5" 23.5" Large S3100L Step Stove 18" 9.5" 10" 32" 16" 23.5" Regency Freestanding Woodstove INSTALLATION Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36" From From Flue Min. Min.Hearth Unit Unit Center-line Width to Rear Wall G H I J K L Small F1100S with Airmate 11" 7" 23" 13.5" 46" 39" with Rear Deflector 13" 5" 25" 11.5" 50" 37" Medium F2100M with Airmate 10" 4.5" 22" 11.5" 44" 41.5" with Rear Deflector 14" 7" 26.5" 14" 52" 44" Medium S2100M Step Stove 10" 4.5" 22" 11.5" 44" 41.5" Large F3100L with Airmate 16" 9.5" 30" 16" 60" 46.5" with Rear Deflector (not approved for Alcove) Large S3100L Step Stove 16" 9.5" 30" 16" 60" 46.5" Floor Protection A combustible floor must be protected by a non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extending beneath the heater and a minimum of 6" from each side and minimum 16" from the front face of the stove and minimum 6" (or the rear clearance to combustibles whichever is smaller) from the rear of the stove. Minimum Overall Width (X) of Floor Protector for all installations: Small Stove F1100S 36" Medium Stove F2100M 36" Medium Step Stove S2100M 36" Large Stove F3100L 40" Large Step Stove S3100L 40" NOTE: In Canada, floor protection must extend 18" to the front and 8" to each side of the stove. Minimum Overall Depth (Y) of Floor Protector Residential Unit "C" Vent Y Z Small F1100S with Airmate 38" 6" with Rear Deflector 38" 6" Medium F2100M with Airmate 43" 6" with Rear Deflector 43 6" Medium S2100M Step Stove 43" 6" La...

Dieses Handbuch ist für folgende Modelle:
Kamine - FREESTANDING WOODSTOVES F1100S (2.06 mb)
Kamine - FREESTANDING WOODSTOVES F2100M (2.06 mb)
Kamine - FREESTANDING WOODSTOVES S2100M (2.06 mb)
Kamine - FREESTANDING WOODSTOVES S3100L (2.06 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien