Anleitung Zusammenfassung
MEASURE FLUE FROM HEATER CENTER-LINE A D BACKWALL SIDEWALLB E G G I BACKWALL SIDEWALLSIDEWALL H J F ADJACENT WALL SIDEWALLC MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST. DELTA, BC V4G 1H4 SIDEWALL G 255 mm / 10 in I 570 mm / 22.5in BACKWALL H 115 mm / 4.5in J 290 mm / 11.5in 2001 20032002 * In Canada, floor protection must extend 18" to the front and 8" to each side of the stove. Regency Freestanding Woodstove SAFETY LABEL This is a copy of the label that accompanies of the back of the stove. We have printed a NOTE: Regency units are constantly being each Regency Large Freestanding Woodstove copy of the contents here for your review. improved. Check the label on the unit and if there (F3100L). It is located in the upper right corner is a difference, the label on the unit is the correct one. UNITED STATES ENVIRONMENTAL PROTECTION AGENCY F3100L WITH AIRMATE SHIELD MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS F3100L WITH AIRMATE SHIELD RESIDENTIAL INSTALLATION USING SINGLE WALL CONNECTOR SIDEWALL A 460 mm / 18 in D 810 mm / 32 in BACKWALL B 305 mm / 12 in E 470 mm / 18.5in CORNER C 215 mm / 8.5in F 560 mm / 22 in INSTALLATION USING LISTED DOUBLE WALL CONNECTOR -MOBILE HOME SIDEWALL A 460 mm / 18 in D 810 mm / 32 in BACKWALL B 240 mm / 9.5in E 405 mm / 16 in CORNER C 255 mm / 10 in F 595 mm / 23.5in INSTALLATION USING LISTED DOUBLE WALL CONNECTOR - RESIDENTIAL CLOSE CLEARANCE SIDEWALL A 405 mm / 16 in D 760 mm / 30 in BACKWALL B 240 mm / 9.5in E 405 mm / 16 in CORNER C 215 mm / 8.5in F 560 mm / 22 in SIDEWALL G 405 mm / 16 in I 760 mm / 30 in BACKWALL H 240 mm / 9.5in J 405 mm / 16 in MEASURE FLUE FROM HEATER CENTER-LINE COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM: SECURITY MODEL S2100, ICC EXCEL 2100. IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL- FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS. MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL. FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS INSTALLATION USING LISTED DOUBLE WALL CONNECTOR - ALCOVE HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS. DO NOT REMOVE THIS LABEL 102 CERTIFIED TO COMPLY WITH JULY 1990, PARTICULATE EMISSION STANDARDS. MADE IN CANADA JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC CAUTION DATE OF MANUFACTURE2001 20032002 WD 908-351 01/03 A D BACKWALL SIDEWALLB E G G I BACKWALL SIDEWALLSIDEWALL H J F ADJACENT WALL SIDEWALLC INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERAT- ING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY. SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. F3100L WITHOUT AIRMATE SHIELD F3100L WITHOUT AIRMATE SHIELD MEASURE FLUE FROM HEATER CENTER-LINE RESIDENTIAL INSTALLATION USING SINGLE WALL CONNECTOR SIDEWALL A 510 mm / 20 in D 860 mm / 34 in BACKWALL B 355 mm / 14 in E 520 mm / 20.5 in CORNER C 265 mm / 10.5in F 610 mm / 24 in INSTALLATION USING LISTED DOUBLE WA...
Dieses Handbuch ist für folgende Modelle:Kamine - FREESTANDING WOODSTOVES F1100S (2.06 mb)
Kamine - FREESTANDING WOODSTOVES F3100L (2.06 mb)
Kamine - FREESTANDING WOODSTOVES S2100M (2.06 mb)
Kamine - FREESTANDING WOODSTOVES S3100L (2.06 mb)